Remote monitoring of atrial fibrillation recurrence using mHealth technology (REMOTE-AF)

被引:4
|
作者
Adasuriya, Gamith [1 ]
Barsky, Andrey [2 ,3 ]
Kralj-Hans, Ines [1 ]
Mohan, Siddhartha [1 ]
Gill, Simrat [2 ]
Chen, Zhong [1 ]
Jarman, Julian [1 ]
Jones, David [1 ]
Valli, Haseeb [1 ]
Gkoutos, Georgios, V [2 ,3 ]
Markides, Vias [1 ]
Hussain, Wajid [1 ]
Wong, Tom [1 ,4 ,5 ]
Kotecha, Dipak [2 ,6 ]
Haldar, Shouvik [1 ,4 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, Royal Brompton & Harefield Hosp, Heart Rhythm Ctr, Hill End Rd, London UB9 6JH, England
[2] Univ Hosp Birmingham NHS Fdn Trust, Hlth Data Res UK Midlands & NIHR Birmingham Biomed, Birmingham, England
[3] Univ Birmingham, Inst Canc & Genom Sci, Birmingham, England
[4] Imperial Coll London, Natl Heart & Lung Inst, London, England
[5] Kings Coll Hosp London, London, England
[6] Univ Birmingham, Inst Cardiovasc Sci, Birmingham, England
来源
关键词
Remote monitoring; Wearables; Atrial fibrillation; Digital health; Ablation; SMARTWATCH; CONSENSUS;
D O I
10.1093/ehjdh/ztae011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims This proof-of-concept study sought to evaluate changes in heart rate (HR) obtained from a consumer wearable device and compare against implantable loop recorder (ILR)-detected recurrence of atrial fibrillation (AF) and atrial tachycardia (AT) after AF ablation.Methods and results REMOTE-AF (NCT05037136) was a prospectively designed sub-study of the CASA-AF randomized controlled trial (NCT04280042). Participants without a permanent pacemaker had an ILR implanted at their index ablation procedure for longstanding persistent AF. Heart rate and step count were continuously monitored using photoplethysmography (PPG) from a commercially available wrist-worn wearable. Photoplethysmography-recorded HR data were pre-processed with noise filtration and episodes at 1-min interval over 30 min of HR elevations (Z-score = 2) were compared with corresponding ILR data. Thirty-five patients were enrolled, with mean age 70.3 +/- 6.8 years and median follow-up 10 months (interquartile range 8-12 months). Implantable loop recorder analysis revealed 17 out of 35 patients (49%) had recurrence of AF/AT. Compared with ILR recurrence, wearable-derived elevations in HR >= 110 beats per minute had a sensitivity of 95.3%, specificity 54.1%, positive predictive value (PPV) 15.8%, negative predictive value (NPV) 99.2%, and overall accuracy 57.4%. With PPG-recorded HR elevation spikes (non-exercise related), the sensitivity was 87.5%, specificity 62.2%, PPV 39.2%, NPV 92.3%, and overall accuracy 64.0% in the entire patient cohort. In the AF/AT recurrence only group, sensitivity was 87.6%, specificity 68.3%, PPV 53.6%, NPV 93.0%, and overall accuracy 75.0%.Conclusion Consumer wearable devices have the potential to contribute to arrhythmia detection after AF ablation.Study Registration ClinicalTrials.gov Identifier: NCT05037136 https://clinicaltrials.gov/ct2/show/NCT05037136 Graphical Abstract Aims, methods, and findings for REMOTE-AF looking at the detection of AF/AT recurrence using novel composite data from wearables compared with gold standard ILR. AF, atrial fibrillation; AT, atrial tachycardia; HR, heart rate; ILR, implantable loop recorder; LSPAF, long-standing persistent atrial fibrillation; NPV, negative predictive value; PPV, positive predictive value.
引用
收藏
页码:344 / 355
页数:12
相关论文
共 50 条
  • [31] Remote Robotic Navigation for Atrial Fibrillation Ablation
    Steinwender, C.
    JOURNAL FUR KARDIOLOGIE, 2011, 18 (3-4): : 82 - 86
  • [32] Remote monitoring of nests using digital camera technology
    Bolton, Mark
    Butcher, Nigel
    Sharpe, Fiona
    Stevens, Danae
    Fisher, Gareth
    JOURNAL OF FIELD ORNITHOLOGY, 2007, 78 (02) : 213 - 220
  • [33] Changes in healthcare utilisation during implementation of remote atrial fibrillation management: TeleCheck-AF project
    Gawalko, Monika
    Betz, Konstanze
    Hendriks, Veerle
    Hermans, Astrid N. L.
    Van der Velden, Rachel M. J.
    Manninger, Martin
    Chaldoupi, Sevasti-Maria
    Hoogervorst, Henk
    Martens, Herm
    Pluymaekers, Nikki A. H. A.
    Spreeuwenberg, Marieke D.
    Hendriks, Jeroen
    Linz, Dominik
    NETHERLANDS HEART JOURNAL, 2024, 32 (03) : 130 - 139
  • [34] Changes in healthcare utilisation during implementation of remote atrial fibrillation management: TeleCheck-AF project
    Monika Gawałko
    Konstanze Betz
    Veerle Hendriks
    Astrid N. L. Hermans
    Rachel M. J. van der Velden
    Martin Manninger
    Sevasti-Maria Chaldoupi
    Henk Hoogervorst
    Herm Martens
    Nikki A. H. A. Pluymaekers
    Marieke D. Spreeuwenberg
    Jeroen Hendriks
    Dominik Linz
    Netherlands Heart Journal, 2024, 32 : 130 - 139
  • [35] Assessment of Remote Heart Rhythm Sampling Using the AliveCor Heart Monitor to Screen for Atrial Fibrillation: The REHEARSE-AF Study
    Halcox, Julian P. J.
    Wareham, Kathie
    Cardew, Antonia
    Gilmore, Mark
    Barry, James P.
    Phillips, Ceri
    Gravenor, Michael B.
    CIRCULATION, 2017, 136 (19) : 1784 - 1794
  • [36] Loss of Neurohumoral Adaptation in Atrial Fibrillation Predicts AF Recurrence
    Govindan, Malini
    Bizrah, Mukhtar
    Younis, Ahmed
    Kiotsekoglou, Anatoli
    Batchvarov, Velislav
    Teoh, Evaun
    Dougal, Kate
    Camm, John
    CIRCULATION, 2009, 120 (18) : S621 - S621
  • [37] The Role of Symptoms in Adherence to mHealth ECG Monitoring for Atrial Fibrillation
    Reading, Meghan
    Biviano, Angelo B.
    Mitrani, Lindsey
    Hickey, Kathleen T.
    CIRCULATION, 2017, 136
  • [38] Effect of type of monitoring on verification of atrial fibrillation recurrence after catheter ablation: Comparison of the 7 day Holter monitoring and implantable monitor with remote control
    Taborsky, M.
    Skala, T.
    Fedorco, M.
    Grofkova, H.
    Jarkovsky, J.
    EUROPEAN HEART JOURNAL, 2015, 36 : 731 - 732
  • [39] Personalized remote monitoring of atrial fibrillation and ventricular arrhythmias in patients with electronic implant devices
    Arbelo, Elena
    Trucco, Emilce
    Laleci, Gokce B.
    Yang, Mahoua
    Chronaki, Catherine
    Hinterbucnher, Lynne
    Guillen, Alejandra
    Dogac, Asuman
    Brugada, Josep
    CIRCULATION, 2012, 125 (19) : E853 - E854
  • [40] Early detection of atrial fibrillation in a patient with AL cardiac amyloidosis: role of remote monitoring
    Prandi, Francesca Romana
    Morgagni, Riccardo
    Zanin, Federico
    Celotto, Roberto
    Uccello, Giuseppe
    Zizzari, Annagiulia
    Cantonetti, Maria
    Romeo, Francesco
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0N) : N132 - N133