Remote monitoring of atrial fibrillation recurrence using mHealth technology (REMOTE-AF)

被引:4
|
作者
Adasuriya, Gamith [1 ]
Barsky, Andrey [2 ,3 ]
Kralj-Hans, Ines [1 ]
Mohan, Siddhartha [1 ]
Gill, Simrat [2 ]
Chen, Zhong [1 ]
Jarman, Julian [1 ]
Jones, David [1 ]
Valli, Haseeb [1 ]
Gkoutos, Georgios, V [2 ,3 ]
Markides, Vias [1 ]
Hussain, Wajid [1 ]
Wong, Tom [1 ,4 ,5 ]
Kotecha, Dipak [2 ,6 ]
Haldar, Shouvik [1 ,4 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, Royal Brompton & Harefield Hosp, Heart Rhythm Ctr, Hill End Rd, London UB9 6JH, England
[2] Univ Hosp Birmingham NHS Fdn Trust, Hlth Data Res UK Midlands & NIHR Birmingham Biomed, Birmingham, England
[3] Univ Birmingham, Inst Canc & Genom Sci, Birmingham, England
[4] Imperial Coll London, Natl Heart & Lung Inst, London, England
[5] Kings Coll Hosp London, London, England
[6] Univ Birmingham, Inst Cardiovasc Sci, Birmingham, England
来源
关键词
Remote monitoring; Wearables; Atrial fibrillation; Digital health; Ablation; SMARTWATCH; CONSENSUS;
D O I
10.1093/ehjdh/ztae011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims This proof-of-concept study sought to evaluate changes in heart rate (HR) obtained from a consumer wearable device and compare against implantable loop recorder (ILR)-detected recurrence of atrial fibrillation (AF) and atrial tachycardia (AT) after AF ablation.Methods and results REMOTE-AF (NCT05037136) was a prospectively designed sub-study of the CASA-AF randomized controlled trial (NCT04280042). Participants without a permanent pacemaker had an ILR implanted at their index ablation procedure for longstanding persistent AF. Heart rate and step count were continuously monitored using photoplethysmography (PPG) from a commercially available wrist-worn wearable. Photoplethysmography-recorded HR data were pre-processed with noise filtration and episodes at 1-min interval over 30 min of HR elevations (Z-score = 2) were compared with corresponding ILR data. Thirty-five patients were enrolled, with mean age 70.3 +/- 6.8 years and median follow-up 10 months (interquartile range 8-12 months). Implantable loop recorder analysis revealed 17 out of 35 patients (49%) had recurrence of AF/AT. Compared with ILR recurrence, wearable-derived elevations in HR >= 110 beats per minute had a sensitivity of 95.3%, specificity 54.1%, positive predictive value (PPV) 15.8%, negative predictive value (NPV) 99.2%, and overall accuracy 57.4%. With PPG-recorded HR elevation spikes (non-exercise related), the sensitivity was 87.5%, specificity 62.2%, PPV 39.2%, NPV 92.3%, and overall accuracy 64.0% in the entire patient cohort. In the AF/AT recurrence only group, sensitivity was 87.6%, specificity 68.3%, PPV 53.6%, NPV 93.0%, and overall accuracy 75.0%.Conclusion Consumer wearable devices have the potential to contribute to arrhythmia detection after AF ablation.Study Registration ClinicalTrials.gov Identifier: NCT05037136 https://clinicaltrials.gov/ct2/show/NCT05037136 Graphical Abstract Aims, methods, and findings for REMOTE-AF looking at the detection of AF/AT recurrence using novel composite data from wearables compared with gold standard ILR. AF, atrial fibrillation; AT, atrial tachycardia; HR, heart rate; ILR, implantable loop recorder; LSPAF, long-standing persistent atrial fibrillation; NPV, negative predictive value; PPV, positive predictive value.
引用
收藏
页码:344 / 355
页数:12
相关论文
共 50 条
  • [21] Remote monitoring and the twin epidemics of atrial fibrillation and chronic heart failure
    Santini, Massimo
    EUROPACE, 2013, 15 : 47 - 48
  • [22] Diagnosis of Atrial Fibrillation by Means of ImplantableDevices. The Role of Remote Monitoring
    Cervesato, Eugenio
    Bruschetta, Eugenia
    Fantin, Denis
    Loro, Francesca
    Zadnik, Delia
    Brieda, Marco
    Dametto, Ermanno
    Del Bianco, Federica
    Zardo, Sara
    Pollesel, Edda
    Zorzi, Catya
    Cassin, Matteo
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 817 - 820
  • [23] Remote navigation and ablation of atrial fibrillation
    Pappone, Carlo
    Santinelli, Vincenzo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 : S18 - S20
  • [24] Remote magnetic navigation in atrial fibrillation
    Szili-Torok, Tamas
    Akca, Ferdi
    EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (03) : 249 - 255
  • [25] Remote control of implanted devices through Home Monitoring™ technology improves detection and clinical management of atrial fibrillation
    Ricci, Renato Pietro
    Morichelli, Loredana
    Santini, Massimo
    EUROPACE, 2009, 11 (01): : 54 - 61
  • [26] Remote control of implanted devices through home monitoring technology improves detection and clinical management of atrial fibrillation
    Ricci, R. P.
    Morichelli, L.
    Santini, M.
    EUROPEAN HEART JOURNAL, 2008, 29 : 115 - 116
  • [27] Remote patient monitoring using mHealth technology in cancer care and research: Patients' perspectives, willingness, and current use
    Stuijt, D.
    Kos, M.
    Van Doeveren, E. E. M.
    Dingemans, I.
    Richel, C.
    Eversdijk, M.
    Bosch, J.
    Bins, A. D.
    Bak, M.
    van Oijen, M.
    ANNALS OF ONCOLOGY, 2024, 35 : S1173 - S1173
  • [28] Remote Blood Glucose Monitoring in mHealth Scenarios: A Review
    Lanzola, Giordano
    Losiouk, Eleonora
    Del Favero, Simone
    Facchinetti, Andrea
    Galderisi, Alfonso
    Quaglini, Silvana
    Magni, Lalo
    Cobelli, Claudio
    SENSORS, 2016, 16 (12) : 2 - 16
  • [29] MHEALTH ENABLED REMOTE MONITORING IMPROVES DIABETES OUTCOMES
    Fischer, J.
    Singh, V.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : A88 - A89
  • [30] Monitoring and Detecting Atrial Fibrillation using Wearable Technology
    Nemati, Shamim
    Ghassemi, Mohammad M.
    Ambai, Vaidehi
    Isakadze, Nino
    Levantsevych, Oleksiy
    Shah, Amit
    Clifford, Gari D.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 3394 - 3397