Unveiling Peripherally Inserted Central Catheter Fractures and Related Complications in the Neonatal Intensive Care Unit: A Concise Review

被引:2
|
作者
Balasundaram, Palanikumar [1 ]
Lucena, Michelle H. [2 ]
Jiang, Lan [3 ]
Nafday, Suhas [4 ]
机构
[1] Javon Bea Hosp Riverside, Mercy Hlth Syst, Dept Pediat, Div Neonatol, Rockford, IL 61114 USA
[2] Baylor Coll Med, Texas Childrens Hosp, Dept Pediat, Div Neonatol, Houston, TX USA
[3] Albert Einstein Coll Med, Childrens Hosp Montefiore, Dept Pediat, Bronx, NY USA
[4] Albert Einstein Coll Med, Jack D Weiler Hosp, Childrens Hosp Montefiore, Dept Pediat,Div Neonatol, Bronx, NY USA
关键词
neonatal intensive care unit (nicu); catheter jamming; fracture; picc line complication; peripherally inserted central catheter (picc); CENTRAL VENOUS CATHETER; PERCUTANEOUS RETRIEVAL; SILASTIC CATHETER; REMOVAL; EMBOLIZATION; RETENTION; CHILDREN;
D O I
10.7759/cureus.47572
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Peripherally inserted central catheters (PICCs) have become popular over tunneled catheters in neonatal intensive care units (NICUs) due to their ease of use and convenience. Although rare, a PICC fracture can be a severe and potentially fatal complication. This narrative review aims to identify factors predisposing neonates to PICC fracture and related complications, such as catheter jamming, and explore strategies for preventing and detecting this complication. A thorough search of PubMed and Google Scholar was conducted using relevant keywords to identify articles discussing PICC fracture in neonates. The review encompassed English-language literature on PICC fracture in neonates, with additional pertinent publications identified through citation searching. The incidence of PICC fracture in neonates varies from less than 1% to 10%, with a higher risk associated with prolonged catheterization, lower gestational age and lower birth weight, and the use of multi-lumen catheters. PICC fractures can occur during insertion, maintenance, or removal. Factors such as catheter duration, gestational age, birth weight, and catheter type increase the risk of PICC fracture. Excessive syringe pressure, securement failure, and excessive force during removal are contributing factors. Catheter fatigue and thin-walled catheter design are common causes of breakage. Preventive measures include proper training of healthcare providers, regular monitoring, early recognition, and prompt catheter removal upon fracture. Preventing and detecting PICC fractures is crucial for neonatal safety. Vigilance during insertion, maintenance, and removal, along with care to avoid excessive force during removal and high pressure during flushing, can help prevent catheter breakage. More research is required to improve prevention strategies for PICC fractures in neonates.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Peripherally Inserted Central Venous Catheter-Related Complications in Adult Patients with Haematological Malignancy
    Wei, L. E. E. Kee
    Sum, C. H. E. O. N. G. Chin
    Gin, G. A. N. Gin
    MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2024, 31 (02): : 52 - 61
  • [42] A National Survey of Neonatal Peripherally Inserted Central Catheter (PICC) Practices
    Sharpe, Elizabeth
    Pettit, Janet
    Ellsbury, Dan L.
    ADVANCES IN NEONATAL CARE, 2013, 13 (01) : 55 - 74
  • [43] Peripherally inserted central catheters are equivalent to centrally inserted catheters in intensive care unit patients for central venous pressure monitoring
    Heath E. Latham
    Scott T. Rawson
    Timothy T. Dwyer
    Chirag C. Patel
    Jo A. Wick
    Steven Q. Simpson
    Journal of Clinical Monitoring and Computing, 2012, 26 : 85 - 90
  • [44] Complications associated with peripherally inserted central catheter use during pregnancy
    Ogura, JM
    Francois, KE
    Perlow, JH
    Elliott, JP
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 188 (05) : 1223 - 1225
  • [45] Risk Factors for Peripherally Inserted Central Venous Catheter Complications in Children
    Jumani, Ketan
    Advani, Sonali
    Reich, Nicholas G.
    Gosey, Leslie
    Milstone, Aaron M.
    JAMA PEDIATRICS, 2013, 167 (05) : 429 - 435
  • [46] Clinical study of complications of a peripherally inserted central catheter in cancer patients
    Bonfim, Andre Luis Victor
    de Brito, Germana Alves
    Baptista, Aline Lourenco
    Andrade, Luis Andre Silvestre
    Imanishe, Marina Harume
    Pereira, Benedito Jorge
    NURSING OPEN, 2023, 10 (07): : 4480 - 4489
  • [47] Peripherally inserted central catheters are equivalent to centrally inserted catheters in intensive care unit patients for central venous pressure monitoring
    Latham, Heath E.
    Rawson, Scott T.
    Dwyer, Timothy T.
    Patel, Chirag C.
    Wick, Jo A.
    Simpson, Steven Q.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (02) : 85 - 90
  • [48] Complication rates among peripherally inserted central venous catheters and centrally inserted central catheters in the medical intensive care unit
    Nolan, Matthew E.
    Yadav, Hemang
    Cawcutt, Kelly A.
    Cartin-Ceba, Rodrigo
    JOURNAL OF CRITICAL CARE, 2016, 31 (01) : 238 - 242
  • [49] Prevalence of complications associated with the use of a peripherally inserted central catheter in newborns: A systematic review protocol
    Sarmento Diniz, Edienne Rosangela
    de Medeiros, Kleyton Santos
    Rosendo da Silva, Richardson Augusto
    Cobucci, Ricardo Ney
    Roncalli, Angelo Giuseppe
    PLOS ONE, 2021, 16 (07):
  • [50] A Randomized Trial of Complications of Peripherally and Centrally Inserted Central Lines in the Neuro-Intensive Care Unit: Results of the NSPVC Trial
    Nicholas J. Brandmeir
    Justin R. Davanzo
    Russell Payne
    Emily P. Sieg
    Ashiya Hamirani
    Annie Tsay
    Jeffrey Watkins
    Sprague W. Hazard
    J. Christopher Zacko
    Neurocritical Care, 2020, 32 : 400 - 406