Accelerometer-based portable navigation, a faster guide compared to computer-assisted navigation in bilateral total knee arthroplasty-a randomized controlled study

被引:6
|
作者
Swamy, Arun M. [1 ]
Malhotra, Rajesh [1 ]
Digge, Vijaykumar [1 ]
Manhas, Vikrant [1 ]
Gautam, Deepak [1 ]
Srivastava, Deep Narayana [2 ]
机构
[1] All India Inst Med Sci AIIMS, Dept Orthopaed, Room 139,Teaching Block,Ansari Nagar East, New Delhi 110029, India
[2] All India Inst Med Sci AIIMS, Dept Radiodiag, New Delhi 110029, India
关键词
Computer navigation; Accelerometer-based navigation; Total knee arthroplasty; BLOOD-LOSS; REPLACEMENT; OUTCOMES; SYSTEM;
D O I
10.1007/s00167-021-06842-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose There are limited studies in the literature comparing the alignment accuracy of the large console, imageless, computer-assisted navigation (CAN) and portable, hand-held, accelerometer-based navigation (ABN) in total knee arthroplasty (TKA). This study was aimed to compare the operative time, blood loss, radiological, clinical and functional outcomes between CAN- and ABN-guided bilateral TKA. Methods From Jan 2016 to Dec 2017, 50 patients who underwent bilateral TKA were randomized to undergo either CAN-guided or ABN-guided TKA. Tourniquet time and blood loss were recorded, and intra-op complications were noted. Post-op radiological outcomes at 2 weeks were compared between the groups. The clinical and functional outcomes using the American Knee Society Scores (KSS) and Oxford Knee Score (OKS) were recorded pre-operatively and post-operatively at 3, 6, 12 months and at the end of the study with a minimum follow-up of 48 months. Results Both groups were well-matched in terms of patient demographic parameters. The mean surgical time per knee was significantly lower in the ABN group (54.5 +/- 5.6 min) compared to the CAN group (61.7 +/- 13.7 min; p < 0.01). Mean blood loss per knee in the ABN group was 592.1 +/- 245.3 mL compared to 682.8 +/- 322.0 in the CAN group (p = 0.11). In the ABN group, the mean post-op mechanical axis was 1.2 +/- 3.2 degrees (vs 1.5 +/- 2.2 degrees in the CAN group, p 0.6), the frontal femoral angle was 88.8 +/- 2.3 degrees (vs 88.8 +/- 1.8 degrees in the CAN group, p 1.0) and frontal tibial angle was 90.1 +/- 1.6 degrees (vs 89.7 +/- 1.1 degrees in the CAN group, p 0.14). At 48 month follow-up, the mean functional KSS in the ABN group was 89.0 +/- 5.7 (vs 88.1 +/- 4.5 in the CAN group, p 0.37) and the mean OKS was 40.5 +/- 2.8 (vs 39.6 +/- 3.2 in the CAN group, p 0.12). Conclusion Portable, hand-held ABN offers alignment accuracy and functional outcomes in TKA similar to that with CAN, with a reduced duration of surgery. There was no advantage of either of the techniques in terms of clinical or functional outcomes at 48 month follow-up.
引用
收藏
页码:786 / 792
页数:7
相关论文
共 50 条
  • [31] Computed tomography-based navigation versus accelerometer-based portable navigation in total hip arthroplasty for dysplastic hip osteoarthritis
    Tanaka, Shinya
    Osawa, Yusuke
    Takegami, Yasuhiko
    Funahashi, Hiroto
    Ido, Hiroaki
    Asamoto, Takamune
    Imagama, Shiro
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2025, 35 (01):
  • [32] Computer-assisted navigation increases precision of component placement in total knee arthroplasty
    Haaker, RG
    Stockheim, M
    Kamp, M
    Proff, G
    Breitenfelder, J
    Ottersbach, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (433) : 152 - 159
  • [33] Computer-Assisted Navigation in Total Knee Arthroplasty without Femoral Hardware Removal
    Hernandez-Vaquero, D.
    Suarez-Vazquez, A.
    Iglesias-Fernandez, S.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2012, 79 (04) : 331 - 334
  • [34] Clinical outcomes of computer-assisted total knee arthroplasty using pinless navigation
    Jiang, Lei
    Chen, Jerry Yongqiang
    Chong, Hwei-Chi
    Chia, Shi-Lu
    Lo, Ngai-Nung
    Yeo, Seng Jin
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (01):
  • [35] Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty
    A. J. Graydon
    S. Malak
    I. A. Anderson
    R. P. Pitto
    International Orthopaedics, 2009, 33 : 975 - 979
  • [36] Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty
    Graydon, A. J.
    Malak, S.
    Anderson, I. A.
    Pitto, R. P.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 975 - 979
  • [37] Computer-Assisted Navigation Software Advancements Improve the Accuracy of Total Knee Arthroplasty
    Molli, Ryan G.
    Anderson, Kevin C.
    Buehler, Knute C.
    Markel, David C.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (03): : 432 - 438
  • [38] Computer-assisted navigation increases precision of component placement in total knee arthroplasty
    Pandher, D. S.
    Oh, K. J.
    Boaparai, R. S.
    Josan, G. S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (454) : 281 - 282
  • [39] Evaluation of Total Knee Arthroplasty Performed With and Without Computer Navigation: A Bilateral Total Knee Arthroplasty Study
    Johnson, Derek R.
    Dennis, Douglas A.
    Kindsfater, Kirk A.
    Kim, Raymond H.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03): : 455 - 458
  • [40] Accuracy of A Handheld Accelerometer-Based Navigation System for Femoral and Tibial Resection in Total Knee Arthroplasty
    Huang, Eddie H.
    Copp, Steven N.
    Bugbee, William D.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (11): : 1906 - 1910