Accelerometer-based portable navigation, a faster guide compared to computer-assisted navigation in bilateral total knee arthroplasty-a randomized controlled study

被引:6
|
作者
Swamy, Arun M. [1 ]
Malhotra, Rajesh [1 ]
Digge, Vijaykumar [1 ]
Manhas, Vikrant [1 ]
Gautam, Deepak [1 ]
Srivastava, Deep Narayana [2 ]
机构
[1] All India Inst Med Sci AIIMS, Dept Orthopaed, Room 139,Teaching Block,Ansari Nagar East, New Delhi 110029, India
[2] All India Inst Med Sci AIIMS, Dept Radiodiag, New Delhi 110029, India
关键词
Computer navigation; Accelerometer-based navigation; Total knee arthroplasty; BLOOD-LOSS; REPLACEMENT; OUTCOMES; SYSTEM;
D O I
10.1007/s00167-021-06842-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose There are limited studies in the literature comparing the alignment accuracy of the large console, imageless, computer-assisted navigation (CAN) and portable, hand-held, accelerometer-based navigation (ABN) in total knee arthroplasty (TKA). This study was aimed to compare the operative time, blood loss, radiological, clinical and functional outcomes between CAN- and ABN-guided bilateral TKA. Methods From Jan 2016 to Dec 2017, 50 patients who underwent bilateral TKA were randomized to undergo either CAN-guided or ABN-guided TKA. Tourniquet time and blood loss were recorded, and intra-op complications were noted. Post-op radiological outcomes at 2 weeks were compared between the groups. The clinical and functional outcomes using the American Knee Society Scores (KSS) and Oxford Knee Score (OKS) were recorded pre-operatively and post-operatively at 3, 6, 12 months and at the end of the study with a minimum follow-up of 48 months. Results Both groups were well-matched in terms of patient demographic parameters. The mean surgical time per knee was significantly lower in the ABN group (54.5 +/- 5.6 min) compared to the CAN group (61.7 +/- 13.7 min; p < 0.01). Mean blood loss per knee in the ABN group was 592.1 +/- 245.3 mL compared to 682.8 +/- 322.0 in the CAN group (p = 0.11). In the ABN group, the mean post-op mechanical axis was 1.2 +/- 3.2 degrees (vs 1.5 +/- 2.2 degrees in the CAN group, p 0.6), the frontal femoral angle was 88.8 +/- 2.3 degrees (vs 88.8 +/- 1.8 degrees in the CAN group, p 1.0) and frontal tibial angle was 90.1 +/- 1.6 degrees (vs 89.7 +/- 1.1 degrees in the CAN group, p 0.14). At 48 month follow-up, the mean functional KSS in the ABN group was 89.0 +/- 5.7 (vs 88.1 +/- 4.5 in the CAN group, p 0.37) and the mean OKS was 40.5 +/- 2.8 (vs 39.6 +/- 3.2 in the CAN group, p 0.12). Conclusion Portable, hand-held ABN offers alignment accuracy and functional outcomes in TKA similar to that with CAN, with a reduced duration of surgery. There was no advantage of either of the techniques in terms of clinical or functional outcomes at 48 month follow-up.
引用
收藏
页码:786 / 792
页数:7
相关论文
共 50 条
  • [21] Does computer-assisted surgical navigation total knee arthroplasty reduce venous thromboembolism compared with conventional total knee arthroplasty?
    Ooi, L. H.
    Lo, N. N.
    Yeo, S. J.
    Ong, B. C.
    Ding, Z. P.
    Lefi, A.
    SINGAPORE MEDICAL JOURNAL, 2008, 49 (08) : 610 - 614
  • [22] Using Accelerometer-Based Portable Navigation to Perform Accurate Total Knee Arthroplasty Bone Resection in Asian Patients
    Ueyama, Hideki
    Matsui, Yoshio
    Minoda, Yukihide
    Matsuura, Masanori
    Nakamura, Hiroaki
    ORTHOPEDICS, 2017, 40 (03) : E465 - E472
  • [23] Experience with computer-assisted navigation for total knee arthroplasty in a community setting
    Carter, Ralph E., III
    Rush, Paul F.
    Smid, John A.
    Smith, Whitney L.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (05): : 707 - 713
  • [24] The cost-effectiveness of computer-assisted navigation in total knee arthroplasty
    Novak, Erik J.
    Silverstein, Marc D.
    Bozic, Kevin J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (11): : 2389 - 2397
  • [25] Accelerometer-Based Navigation Is as Accurate as Optical Computer Navigation in Restoring the Joint Line and Mechanical Axis After Total Knee Arthroplasty A Prospective Matched Study
    Goh, Graham Seow-Hng
    Liow, Ming Han Lincoln
    Lim, Winston Shang-Rong
    Tay, Darren Keng-Jin
    Yeo, Seng Jin
    Tan, Mann Hong
    JOURNAL OF ARTHROPLASTY, 2016, 31 (01): : 92 - 97
  • [26] Extramedullary Guides Versus Portable, Accelerometer-Based Navigation for Tibial Alignment in Total Knee Arthroplasty: A Randomized, Controlled Trial: Winner of the 2013 HAP PAUL Award
    Nam, Denis
    Cody, Elizabeth A.
    Nguyen, Joseph T.
    Figgie, Mark P.
    Mayman, David J.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02): : 288 - 294
  • [27] Does Augmented Reality-based Portable Navigation Improve the Accuracy of Cup Placement in THA Compared With Accelerometer-based Portable Navigation? A Randomized Controlled Trial
    Kurosaka, Kenji
    Ogawa, Hiroyuki
    Hirasawa, Naoyuki
    Saito, Masayoshi
    Nakayama, Tsutomu
    Tsukada, Sachiyuki
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2023, 481 (08) : 1515 - 1523
  • [28] Accelerometer-Based Portable Navigation System Is Useful for Tibial Bone Cutting in Modified Kinematically Aligned Total Knee Arthroplasty
    Tsubosaka, Masanori
    Kamenaga, Tomoyuki
    Kuroda, Yuichi
    Takayama, Koji
    Hashimoto, Shingo
    Ishida, Kazunati
    Hayashi, Shinya
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    JOURNAL OF KNEE SURGERY, 2021, 34 (08) : 870 - 876
  • [29] Cadaveric analysis of an accelerometer-based portable navigation device for distal femoral cutting block alignment in total knee arthroplasty
    Nam, Denis
    Jerabek, Seth A.
    Cross, Michael B.
    Mayman, David J.
    COMPUTER AIDED SURGERY, 2012, 17 (04) : 205 - 210
  • [30] Efficacy of Portable Accelerometer-Based Navigation Devices versus Conventional Guides in Total Knee Arthroplasty: A Meta-analysis
    Sun, Han
    Li, Shuxiang
    Wang, Kun
    Wu, Guofeng
    Zhou, Jian
    Sun, Xiaoliang
    JOURNAL OF KNEE SURGERY, 2020, 33 (07) : 691 - 703