Video-based real-time monitoring for heart rate and respiration rate

被引:25
|
作者
Alnaggar, Mona [1 ]
Siam, Ali I. [2 ]
Handosa, Mohamed [3 ]
Medhat, T. [4 ]
Rashad, M. Z. [3 ]
机构
[1] Kafrelsheikh Univ, Fac Artificial Intelligence, Dept Robot & Intelligent Machines, Kafr Al Sheikh, Egypt
[2] Kafrelsheikh Univ, Fac Artificial Intelligence, Dept Embedded Network Syst Technol, Kafr Al Sheikh, Egypt
[3] Mansoura Univ, Fac Comp & Informat, Dept Comp Sci, Mansoura, Egypt
[4] Kafrelsheikh Univ, Fac Engn, Dept Elect Engn, Kafr Al Sheikh, Egypt
关键词
Vital signs monitoring; Remote photoplethysmography (rPPG); COHFACE; HR monitoring; Telehealth; MediaPipe; ROBUST;
D O I
10.1016/j.eswa.2023.120135
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
During the last decade, the world faced many pandemics, causing medical service providers to struggle with diagnosing, following up with patients, keeping daily records, and eliminating infection spread. All of these factors force us to pay close attention in order to make vital sign measurements safer and easier. Respiration Rate (RR) and Heart Rate (HR) are the most measured signs for patients. Remote photoplethysmography (rPPG) is a video-based technique for HR monitoring so that telehealth can be easier. This paper proposes a new method-ology for RR and HR estimation depending on non-contact techniques. The proposed architecture relies on monitoring the patients using a camera to view a video stream from which we can extract the rPPG waveform from individuals' faces. The motion and color in the video are first magnified using Eulerian Video Magnification (EVM) and then analyzed in two stages, one for HR estimation and the other for RR estimation. For HR esti-mation, MediaPipe Face Mesh is employed to annotate the boundaries of the most suitable Region of Interest (ROI) from the face image in both RGB and HSV color modes. Then, the integral image for R and V channels, respectively, are computed. The proposed method is based on measuring fluctuations in the value resulting from the integral image, and can therefore extract HR. Whilst for RR estimation, MediaPipe Pose solution is used to annotate the position of specific landmarks on the chest, and then tracking the changes of these landmarks' positions with time. The performance of the proposed method is evaluated using COHFACE dataset. In HR ex-periments, the Mean Absolute Error (MAE) is 2.05 and 2.03 BPM (Beats per Minute), and the Pearson Correlation Coefficient (PCC) is 0.91 and 0.86 for RGB and HSV frames, respectively. In RR experiments, the MAE was 1.62 BrPM (Breaths per Minute) and the PCC is 0.45.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Real-Time Monitoring of Heart Beat Rate and SpO2 Based on Internet of Things
    Hassan, Aveen Uthman
    Salihu, Yahaya Otuoze
    Musa, Mu'azu Jibrin
    INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND ENERGY TECHNOLOGIES (ICECET 2021), 2021, : 1771 - 1774
  • [42] Video-based Heart Rate Measurement From Human Faces
    Pursche, T.
    Krajewski, J.
    Moeller, Reinhard
    2012 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2012, : 544 - +
  • [43] Rate-distortion based real-time wireless video streaming
    Seferoglu, Hulya
    Gurbuz, Ozgur
    Ercetin, Ozgur
    Altunbasak, Yucel
    SIGNAL PROCESSING-IMAGE COMMUNICATION, 2007, 22 (06) : 529 - 542
  • [44] Contactless Methods for Respiration Monitoring and Design of SIW-LWA for Real-Time Respiratory Rate Monitoring
    Sharma, Manvinder
    Singh, Harjinder
    IETE JOURNAL OF RESEARCH, 2023, 69 (11) : 8362 - 8372
  • [45] Fuzzy-based rate control for real-time MPEG video
    Tsang, DHK
    Bensaou, B
    Lam, STC
    IEEE TRANSACTIONS ON FUZZY SYSTEMS, 1998, 6 (04) : 504 - 516
  • [46] Automated Real-Time Processing of Single Lead Electrocardiogram for Simultaneous Heart Rate and Respiratory Rate Monitoring
    Dutta, Disha N.
    Das, Reshmi
    Pal, Saurabh
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2017, 11 (02):
  • [47] A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms
    Tadi, Mojtaba Jafari
    Lehtonen, Eero
    Hurnanen, Tero
    Koskinen, Juho
    Eriksson, Jonas
    Pankaala, Mikko
    Teras, Mika
    Koivisto, Tero
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (11) : 1885 - 1909
  • [48] Design of a Real-Time Heart Rate Monitoring System Using Photoplethysmography and Smartphone
    Singh, Neharika
    Prince, Aashirvad
    Chattopadhyay, Swarnendu
    Patra, Rusha
    Mukherjee, Banibrata
    IEEE INDICON: 15TH IEEE INDIA COUNCIL INTERNATIONAL CONFERENCE, 2018,
  • [49] Real-Time Heart Rate Variability Monitoring Employing a Wearable Telemeter and a Smartphone
    Yamakawa, Toshitaka
    Fujiwara, Koichi
    Miyajima, Miho
    Abe, Erika
    Kano, Manabu
    Ueda, Yuichi
    2014 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA), 2014,
  • [50] Wearable Device for Yogic Breathing with Real-Time Heart Rate and Posture Monitoring
    Puranik, Anmol
    Kanthi, M.
    Nayak, Anupama V.
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2021, 11 (04): : 253 - 261