Video-based real-time monitoring for heart rate and respiration rate

被引:25
|
作者
Alnaggar, Mona [1 ]
Siam, Ali I. [2 ]
Handosa, Mohamed [3 ]
Medhat, T. [4 ]
Rashad, M. Z. [3 ]
机构
[1] Kafrelsheikh Univ, Fac Artificial Intelligence, Dept Robot & Intelligent Machines, Kafr Al Sheikh, Egypt
[2] Kafrelsheikh Univ, Fac Artificial Intelligence, Dept Embedded Network Syst Technol, Kafr Al Sheikh, Egypt
[3] Mansoura Univ, Fac Comp & Informat, Dept Comp Sci, Mansoura, Egypt
[4] Kafrelsheikh Univ, Fac Engn, Dept Elect Engn, Kafr Al Sheikh, Egypt
关键词
Vital signs monitoring; Remote photoplethysmography (rPPG); COHFACE; HR monitoring; Telehealth; MediaPipe; ROBUST;
D O I
10.1016/j.eswa.2023.120135
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
During the last decade, the world faced many pandemics, causing medical service providers to struggle with diagnosing, following up with patients, keeping daily records, and eliminating infection spread. All of these factors force us to pay close attention in order to make vital sign measurements safer and easier. Respiration Rate (RR) and Heart Rate (HR) are the most measured signs for patients. Remote photoplethysmography (rPPG) is a video-based technique for HR monitoring so that telehealth can be easier. This paper proposes a new method-ology for RR and HR estimation depending on non-contact techniques. The proposed architecture relies on monitoring the patients using a camera to view a video stream from which we can extract the rPPG waveform from individuals' faces. The motion and color in the video are first magnified using Eulerian Video Magnification (EVM) and then analyzed in two stages, one for HR estimation and the other for RR estimation. For HR esti-mation, MediaPipe Face Mesh is employed to annotate the boundaries of the most suitable Region of Interest (ROI) from the face image in both RGB and HSV color modes. Then, the integral image for R and V channels, respectively, are computed. The proposed method is based on measuring fluctuations in the value resulting from the integral image, and can therefore extract HR. Whilst for RR estimation, MediaPipe Pose solution is used to annotate the position of specific landmarks on the chest, and then tracking the changes of these landmarks' positions with time. The performance of the proposed method is evaluated using COHFACE dataset. In HR ex-periments, the Mean Absolute Error (MAE) is 2.05 and 2.03 BPM (Beats per Minute), and the Pearson Correlation Coefficient (PCC) is 0.91 and 0.86 for RGB and HSV frames, respectively. In RR experiments, the MAE was 1.62 BrPM (Breaths per Minute) and the PCC is 0.45.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Evaluation of a video-based measure of driver heart rate
    Kuo, Jonny
    Koppel, Sjaan
    Charlton, Judith L.
    Rudin-Brown, Christina M.
    JOURNAL OF SAFETY RESEARCH, 2015, 54 : 55 - 59
  • [22] WiFi-based Real-time Breathing and Heart Rate Monitoring during Sleep
    Gu, Yu
    Zhang, Xiang
    Liu, Zhi
    Ren, Fuji
    2019 IEEE GLOBAL COMMUNICATIONS CONFERENCE (GLOBECOM), 2019,
  • [23] Video-Based Physiologic Monitoring During an Acute Hypoxic Challenge: Heart Rate, Respiratory Rate, and Oxygen Saturation
    Addison, Paul S.
    Jacquel, Dominique
    Foo, David M. H.
    Antunes, Andre
    Borg, Ulf R.
    ANESTHESIA AND ANALGESIA, 2017, 125 (03): : 860 - 873
  • [24] Real-Time Heart Rate Monitoring Using Arduino and Pulse Sensor
    Yazid, Mohd Rafis
    Jaafar, Afiza Nur
    Abdullah, Rina
    Dzulkefli, Nik Nur Shaadah Nik
    Omar, Suziana
    2024 IEEE INTERNATIONAL CONFERENCE ON AUTOMATIC CONTROL AND INTELLIGENT SYSTEMS, I2CACIS 2024, 2024, : 368 - 372
  • [25] Architecture for real-time heart rate monitoring from a social robot
    Martinez-Rodrigo, Arturo
    Castillo, Jose Carlos
    Carrasco-Martinez, Sara
    Costa, Angelo
    REVISTA IBEROAMERICANA DE AUTOMATICA E INFORMATICA INDUSTRIAL, 2024, 21 (04): : 362 - 373
  • [26] Real-time monitoring of heart rate variability in critically ill patients
    Kasaoka, Shunji
    Nakahara, Takashi
    Kawamura, Yoshikatsu
    Tsuruta, Ryosuke
    Maekawa, Tsuyoshi
    JOURNAL OF CRITICAL CARE, 2010, 25 (02) : 313 - 316
  • [27] Real-Time Approaches for Heart Rate Monitoring using Imaging Photoplethysmography
    Fallet, Sibylle
    Mirmohamadsadeghi, Leila
    Moser, Virginie
    Braun, Fabian
    Vesin, Jean-Marc
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 345 - 348
  • [28] A Real-Time Evaluation Algorithm for Noncontact Heart Rate Variability Monitoring
    Han, Xiangyu
    Zhai, Qian
    Zhang, Ning
    Zhang, Xiufeng
    He, Long
    Pan, Min
    Zhang, Bin
    Liu, Tao
    SENSORS, 2023, 23 (15)
  • [29] Real-Time Heart Rate Monitoring via Batteryless RFID Tags
    Barati, Mahdi
    Khoshniyat, Hamed
    Mirzavand, Rashid
    2024 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC 2024, 2024, : 21 - 23
  • [30] A real-time heart rate estimation framework based on a facial video while wearing a mask
    Ryu, JongSong
    Hong, SunChol
    Liang, Shili
    Pak, SinIl
    Zhang, Lei
    Wang, Suqiu
    Lian, Yueqi
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (03) : 887 - 900