Test accuracy of artificial intelligence-based grading of fundus images in diabetic retinopathy screening: A systematic review

被引:6
|
作者
Zhelev, Zhivko [1 ]
Peters, Jaime [1 ]
Rogers, Morwenna [2 ]
Allen, Michael [3 ]
Kijauskaite, Goda [4 ]
Seedat, Farah [4 ]
Wilkinson, Elizabeth [5 ]
Hyde, Christopher [1 ]
机构
[1] Univ Exeter, Univ Exeter Med Sch, Exeter Test Grp, Coll House 1-25,St Lukes Campus, Exeter EX1 2LU, England
[2] Univ Exeter, Univ Exeter Med Sch, NIHR ARC South West Peninsula PenARC, Exeter, England
[3] Univ Exeter, Univ Exeter Med Sch, Exeter, England
[4] UK Natl Screening Comm, London, England
[5] Northern Devon Healthcare NHS Trust, Exeter, Devon, England
关键词
Artificial intelligence; fundus imaging; sensitivity and specificity; systematic review; diabetic retinopathy; screening; AUTOMATED DETECTION; VALIDATION; PHOTOGRAPHY; PROGRESSION; SOFTWARE;
D O I
10.1177/09691413221144382
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives To systematically review the accuracy of artificial intelligence (AI)-based systems for grading of fundus images in diabetic retinopathy (DR) screening. Methods We searched MEDLINE, EMBASE, the Cochrane Library and the ClinicalTrials.gov from 1st January 2000 to 27th August 2021. Accuracy studies published in English were included if they met the pre-specified inclusion criteria. Selection of studies for inclusion, data extraction and quality assessment were conducted by one author with a second reviewer independently screening and checking 20% of titles. Results were analysed narratively. Results Forty-three studies evaluating 15 deep learning (DL) and 4 machine learning (ML) systems were included. Nine systems were evaluated in a single study each. Most studies were judged to be at high or unclear risk of bias in at least one QUADAS-2 domain. Sensitivity for referable DR and higher grades was >= 85% while specificity varied and was <80% for all ML systems and in 6/31 studies evaluating DL systems. Studies reported high accuracy for detection of ungradable images, but the latter were analysed and reported inconsistently. Seven studies reported that AI was more sensitive but less specific than human graders. Conclusions AI-based systems are more sensitive than human graders and could be safe to use in clinical practice but have variable specificity. However, for many systems evidence is limited, at high risk of bias and may not generalise across settings. Therefore, pre-implementation assessment in the target clinical pathway is essential to obtain reliable and applicable accuracy estimates.
引用
收藏
页码:97 / 112
页数:16
相关论文
共 50 条
  • [41] Analysis of retinal fundus images for grading of diabetic retinopathy severity
    M. H. Ahmad Fadzil
    Lila Iznita Izhar
    Hermawan Nugroho
    Hanung Adi Nugroho
    Medical & Biological Engineering & Computing, 2011, 49 : 693 - 700
  • [42] Artificial intelligence for diabetic retinopathy screening
    Grzybowski, Andrzej
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [43] Combining Artificial Intelligence and Image Processing for Diagnosing Diabetic Retinopathy in Retinal Fundus Images
    Al-hazaimeh, Obaida M.
    Abu-Ein, Ashraf
    Tahat, Nedal
    Al-Smadi, Ma'moun
    Al-Nawashi, Malek
    INTERNATIONAL JOURNAL OF ONLINE AND BIOMEDICAL ENGINEERING, 2022, 18 (13) : 131 - 151
  • [44] Use of offline artificial intelligence in a smartphone-based fundus camera for community screening of diabetic retinopathy
    Krishnan, Radhika
    Jain, Astha
    Rogye, Ashwini
    Natarajan, Sundaram
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (11) : 3150 - +
  • [45] ASSESSMENT OF ARTIFICIAL INTELLIGENCE SOFTWARE FOR AUTOMATIC SCREENING OF DIABETIC RETINOPATHY BASED ON FUNDUS PHOTOGRAPHS IN MELANODERM SUBJECTS
    Mbaye, Soda
    Aw, Aissatou
    Sy, El Hadji Malick
    Ka, Aly Mbara
    Diagne, Jean Pierre
    Diallo, Hawo Madina
    Samra, Audrey
    Ndiaye, Papa Amadou
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2025, 45 (02): : 330 - 334
  • [46] Development of an Artificial Intelligence-based Diabetic Retinopathy Screening Tool for Optos Ultra-Widefield Imaging
    Peto, T.
    Aiello, L. P.
    Sadda, S.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (2_SUPPL) : 13 - 14
  • [47] Cost-Effectiveness of Artificial Intelligence-Based Retinopathy of Prematurity Screening
    Morrison, Steven
    Chan, R. V. Paul
    Chiang, Michael F.
    Campbell, J. Peter
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [48] Correction: Clinical validation of an artificial intelligence-based diabetic retinopathy screening tool for a national health system
    José Tomás Arenas-Cavalli
    Ignacio Abarca
    Maximiliano Rojas-Contreras
    Fernando Bernuy
    Rodrigo Donoso
    Eye, 2021, 35 : 2910 - 2910
  • [49] Feasibility and Patient Experience of a Pilot Artificial Intelligence-Based Diabetic Retinopathy Screening Program in Northern Ontario
    Bhambhwani, Vishaal
    Whitestone, Noelle
    Patnaik, Jennifer L.
    Ojeda, Alonso
    Scali, James
    Cherwek, David H.
    OPHTHALMIC EPIDEMIOLOGY, 2024,
  • [50] Cost-effectiveness of Artificial Intelligence-Based Retinopathy of Prematurity Screening
    Morrison, Steven L.
    Dukhovny, Dmitry
    Chan, R. V. Paul
    Chiang, Michael F.
    Campbell, J. Peter