Test accuracy of artificial intelligence-based grading of fundus images in diabetic retinopathy screening: A systematic review

被引:6
|
作者
Zhelev, Zhivko [1 ]
Peters, Jaime [1 ]
Rogers, Morwenna [2 ]
Allen, Michael [3 ]
Kijauskaite, Goda [4 ]
Seedat, Farah [4 ]
Wilkinson, Elizabeth [5 ]
Hyde, Christopher [1 ]
机构
[1] Univ Exeter, Univ Exeter Med Sch, Exeter Test Grp, Coll House 1-25,St Lukes Campus, Exeter EX1 2LU, England
[2] Univ Exeter, Univ Exeter Med Sch, NIHR ARC South West Peninsula PenARC, Exeter, England
[3] Univ Exeter, Univ Exeter Med Sch, Exeter, England
[4] UK Natl Screening Comm, London, England
[5] Northern Devon Healthcare NHS Trust, Exeter, Devon, England
关键词
Artificial intelligence; fundus imaging; sensitivity and specificity; systematic review; diabetic retinopathy; screening; AUTOMATED DETECTION; VALIDATION; PHOTOGRAPHY; PROGRESSION; SOFTWARE;
D O I
10.1177/09691413221144382
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives To systematically review the accuracy of artificial intelligence (AI)-based systems for grading of fundus images in diabetic retinopathy (DR) screening. Methods We searched MEDLINE, EMBASE, the Cochrane Library and the ClinicalTrials.gov from 1st January 2000 to 27th August 2021. Accuracy studies published in English were included if they met the pre-specified inclusion criteria. Selection of studies for inclusion, data extraction and quality assessment were conducted by one author with a second reviewer independently screening and checking 20% of titles. Results were analysed narratively. Results Forty-three studies evaluating 15 deep learning (DL) and 4 machine learning (ML) systems were included. Nine systems were evaluated in a single study each. Most studies were judged to be at high or unclear risk of bias in at least one QUADAS-2 domain. Sensitivity for referable DR and higher grades was >= 85% while specificity varied and was <80% for all ML systems and in 6/31 studies evaluating DL systems. Studies reported high accuracy for detection of ungradable images, but the latter were analysed and reported inconsistently. Seven studies reported that AI was more sensitive but less specific than human graders. Conclusions AI-based systems are more sensitive than human graders and could be safe to use in clinical practice but have variable specificity. However, for many systems evidence is limited, at high risk of bias and may not generalise across settings. Therefore, pre-implementation assessment in the target clinical pathway is essential to obtain reliable and applicable accuracy estimates.
引用
收藏
页码:97 / 112
页数:16
相关论文
共 50 条
  • [21] The effectiveness of artificial intelligence-based automated grading and training system in education of manual detection of diabetic retinopathy
    Qian, Xu
    Han, Jingying
    Xian, Song
    Zhao, Yuqing
    Wu, Lili
    Chu, Baorui
    Wei, Guo
    Zheng, Yefeng
    Qiang, Zhang
    Chu, Chunyan
    Cheng, Bian
    Kai, Ma
    Yi, Qu
    FRONTIERS IN PUBLIC HEALTH, 2022, 10
  • [22] Artificial intelligence for telemedicine diabetic retinopathy screening: a review
    Nakayama, Luis Filipe
    Zago Ribeiro, Lucas
    Novaes, Frederico
    Miyawaki, Isabele Ayumi
    Miyawaki, Andresa Emy
    de Oliveira, Juliana Angelica Estevao
    Oliveira, Talita
    Malerbi, Fernando Korn
    Regatieri, Caio Vinicius Saito
    Celi, Leo Anthony
    Silva, Paolo S.
    ANNALS OF MEDICINE, 2023, 55 (02)
  • [23] Correction to: Artificial intelligence for diabetic retinopathy screening: a review
    Andrzej Grzybowski
    Piotr Brona
    Gilbert Lim
    Paisan Ruamviboonsuk
    Gavin S. W. Tan
    Michael Abramoff
    Daniel S. W. Ting
    Eye, 2020, 34 : 604 - 604
  • [24] Artificial Intelligence-Based Referral System for Patients With Diabetic Retinopathy
    Gonzalez-Briceno, Gaspar
    Sanchez, Abraham
    Ortega-Cisneros, Susana
    Salvador Garcia-Contreras, Mario
    Pinedo Diaz, German Alonso
    Ulises Moya-Sanchez, E.
    COMPUTER, 2020, 53 (10) : 77 - 87
  • [25] Associated factors of diabetic retinopathy by artificial intelligence evaluation of fundus images in Japan
    Komatsu, Koji
    Sano, Kei
    Fukai, Kota
    Nakagawa, Ryo
    Nakagawa, Takashi
    Tatemichi, Masayuki
    Nakano, Tadashi
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [26] Associated factors of diabetic retinopathy by artificial intelligence evaluation of fundus images in Japan
    Koji Komatsu
    Kei Sano
    Kota Fukai
    Ryo Nakagawa
    Takashi Nakagawa
    Masayuki Tatemichi
    Tadashi Nakano
    Scientific Reports, 13
  • [27] Use of Artificial Intelligence-Based Detection of Diabetic Retinopathy in the US
    Shah, Shreya A.
    Sokol, Jared T.
    Wai, Karen M.
    Rahimy, Ehsan
    Myung, David
    Mruthyunjaya, Prithvi
    Parikh, Ravi
    JAMA OPHTHALMOLOGY, 2024, 142 (12) : 1171 - 1173
  • [28] Application of Artificial Intelligence for Classification, Segmentation, Early Detection, Early Diagnosis, and Grading of Diabetic Retinopathy From Fundus Retinal Images: A Comprehensive Review
    Rajarajeshwari, G.
    Selvi, G. Chemmalar
    IEEE ACCESS, 2024, 12 : 172499 - 172536
  • [29] Performance of deep neural network-based artificial intelligence method in diabetic retinopathy screening: a systematic review and meta-analysis of diagnostic test accuracy
    Wang, Shirui
    Zhang, Yuelun
    Lei, Shubin
    Zhu, Huijuan
    Li, Jianqiang
    Wang, Qing
    Yang, Jijiang
    Chen, Shi
    Pan, Hui
    EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2020, 183 (01) : 41 - 49
  • [30] Feasibility and accuracy of the screening for diabetic retinopathy using a fundus camera and an artificial intelligence pre-evaluation application
    A. Piatti
    F. Romeo
    R. Manti
    M. Doglio
    B. Tartaglino
    E. Nada
    C. B. Giorda
    Acta Diabetologica, 2024, 61 : 63 - 68