Test accuracy of artificial intelligence-based grading of fundus images in diabetic retinopathy screening: A systematic review

被引:6
|
作者
Zhelev, Zhivko [1 ]
Peters, Jaime [1 ]
Rogers, Morwenna [2 ]
Allen, Michael [3 ]
Kijauskaite, Goda [4 ]
Seedat, Farah [4 ]
Wilkinson, Elizabeth [5 ]
Hyde, Christopher [1 ]
机构
[1] Univ Exeter, Univ Exeter Med Sch, Exeter Test Grp, Coll House 1-25,St Lukes Campus, Exeter EX1 2LU, England
[2] Univ Exeter, Univ Exeter Med Sch, NIHR ARC South West Peninsula PenARC, Exeter, England
[3] Univ Exeter, Univ Exeter Med Sch, Exeter, England
[4] UK Natl Screening Comm, London, England
[5] Northern Devon Healthcare NHS Trust, Exeter, Devon, England
关键词
Artificial intelligence; fundus imaging; sensitivity and specificity; systematic review; diabetic retinopathy; screening; AUTOMATED DETECTION; VALIDATION; PHOTOGRAPHY; PROGRESSION; SOFTWARE;
D O I
10.1177/09691413221144382
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives To systematically review the accuracy of artificial intelligence (AI)-based systems for grading of fundus images in diabetic retinopathy (DR) screening. Methods We searched MEDLINE, EMBASE, the Cochrane Library and the ClinicalTrials.gov from 1st January 2000 to 27th August 2021. Accuracy studies published in English were included if they met the pre-specified inclusion criteria. Selection of studies for inclusion, data extraction and quality assessment were conducted by one author with a second reviewer independently screening and checking 20% of titles. Results were analysed narratively. Results Forty-three studies evaluating 15 deep learning (DL) and 4 machine learning (ML) systems were included. Nine systems were evaluated in a single study each. Most studies were judged to be at high or unclear risk of bias in at least one QUADAS-2 domain. Sensitivity for referable DR and higher grades was >= 85% while specificity varied and was <80% for all ML systems and in 6/31 studies evaluating DL systems. Studies reported high accuracy for detection of ungradable images, but the latter were analysed and reported inconsistently. Seven studies reported that AI was more sensitive but less specific than human graders. Conclusions AI-based systems are more sensitive than human graders and could be safe to use in clinical practice but have variable specificity. However, for many systems evidence is limited, at high risk of bias and may not generalise across settings. Therefore, pre-implementation assessment in the target clinical pathway is essential to obtain reliable and applicable accuracy estimates.
引用
收藏
页码:97 / 112
页数:16
相关论文
共 50 条
  • [1] Diabetic retinopathy screening with confocal fundus camera and artificial intelligence - assisted grading
    Piatti, A.
    Rui, C.
    Gazzina, S.
    Tartaglino, B.
    Romeo, F.
    Manti, R.
    Doglio, M.
    Nada, E.
    Giorda, C. B.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2025, 35 (02) : 679 - 688
  • [2] Screening for Diabetic Retinopathy Using Artificial Intelligence and Smartphone-Based Fundus Images
    Kalavar, Meghana
    Watane, Arjun
    Sridhar, Jayanth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (09)
  • [3] Evaluation of Artificial Intelligence-Based Grading of Diabetic Retinopathy in Primary Care
    Kanagasingam, Yogesan
    Xiao, Di
    Vignarajan, Janardhan
    Preetham, Amita
    Tay-Kearney, Mei-Ling
    Mehrotra, Ateev
    JAMA NETWORK OPEN, 2018, 1 (05) : e182665
  • [4] Artificial intelligence-based screening for diabetic retinopathy at community hospital
    He, Jie
    Chen, Jili
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [5] Artificial intelligence-based screening for diabetic retinopathy at community hospital
    He, Jie
    Cao, Tingyi
    Xu, Feiping
    Wang, Shasha
    Tao, Haiqi
    Wu, Tao
    Sun, Liyan
    Chen, Jili
    EYE, 2020, 34 (03) : 572 - 576
  • [6] Artificial intelligence-based screening for diabetic retinopathy at community hospital
    Jie He
    Tingyi Cao
    Feiping Xu
    Shasha Wang
    Haiqi Tao
    Tao Wu
    Liyan Sun
    Jili Chen
    Eye, 2020, 34 : 572 - 576
  • [7] Diagnostic Accuracy of Artificial Intelligence-Based Automated Diabetic Retinopathy Screening in Real-World Settings: A Systematic Review and Meta-Analysis
    Joseph, Sanil
    Selvaraj, Jerrome
    Mani, Iswarya
    Kumaragurupari, Thandavarayan
    Shang, Xianwen
    Mudgil, Poonam
    Ravilla, Thulasiraj
    He, Mingguang
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 263 : 214 - 230
  • [8] Feasibility and acceptance of artificial intelligence-based diabetic retinopathy screening in Rwanda
    Whitestone, Noelle
    Nkurikiye, John
    Patnaik, Jennifer L.
    Jaccard, Nicolas
    Lanouette, Gabriella
    Cherwek, David H.
    Congdon, Nathan
    Mathenge, Wanjiku
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024, 108 (06) : 840 - 845
  • [9] Artificial Intelligence-Based Screening System for Diabetic Retinopathy in Primary Care
    Baget-Bernaldiz, Marc
    Fontoba-Poveda, Benilde
    Romero-Aroca, Pedro
    Navarro-Gil, Raul
    Hernando-Comerma, Adriana
    Bautista-Perez, Angel
    Llagostera-Serra, Monica
    Morente-Lorenzo, Cristian
    Vizcarro, Montse
    Mira-Puerto, Alejandra
    DIAGNOSTICS, 2024, 14 (17)
  • [10] Accuracy of Autonomous Artificial Intelligence-Based Diabetic Retinopathy Screening in Real-Life Clinical Practice
    Riotto, Eleonora
    Gasser, Stefan
    Potic, Jelena
    Sherif, Mohamed
    Stappler, Theodor
    Schlingemann, Reinier
    Wolfensberger, Thomas
    Konstantinidis, Lazaros
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (16)