Short circuit analysis of a fault-tolerant current-limiting high temperature superconducting transformer in a power system in presence of distributed generations

被引:1
|
作者
Sadeghi, Alireza [1 ]
Bonab, Shahin Alipour [1 ]
Song, Wenjuan [1 ]
Yazdani-Asrami, Mohammad [1 ]
机构
[1] Univ Glasgow, James Watt Sch Engn, Autonomous Syst & Connect Div, Prop Electrificat & Superconduct Grp, Glasgow City G12 8QQ, Scotland
来源
SUPERCONDUCTIVITY | 2024年 / 9卷
关键词
Fault Energy; Heat dissipation; Heat transfer; Insulation; Recovery Time; Temperature rise; AC LOSS; FLUX DIVERTORS; HTS;
D O I
10.1016/j.supcon.2024.100085
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power transformers are key elements for the safe and reliable delivery of electrical energy generated by renewable energy resources to consumers via transmission lines. Fault -tolerant current-limiting High Temperature Superconducting (FTCL HTS) transformers are type of superconducting transformers that tolerate fault for seconds and limit the fault current without the threat of burnout or delamination of tapes and deformation of windings. In this paper, the fault performance of a FTCL HTS transformer in a standard IEEE power system is investigated. The studied transformer is a 50 MVA 132 kV/13.8 kV transformer where both windings are made up of HTS tapes. The understudied power system consists of two microgrids with distributed generators. Part of the power in microgrids is supplied by the upstream grid which is connected to the microgrids through the HTS transformers. Two fault scenarios have been considered in this power system, in each one of these scenarios, a fault happens in one of the microgrids. Two considered fault scenarios have an approximate fault current of 18x to 23x of the rated current in the secondary windings. Results showed that insulated windings in FTCL HTS transformers could substantially reduce the peak temperature of the HTS windings, compared to bare windings. Afterwards, post -fault loading is imposed on the HTS windings, to observe their performance against the current increase after fault clearance. In this case, for the first scenario of the faults, the FTCL HTS transformer could tolerate 192% of post -fault overloading, while this number for the second fault scenario is 170%. Finally, the impact of post -fault loading on the full recovery time was discussed.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Influences of Resistor-Type Superconducting Fault Current Limiter on Power System Transient Stability with Asymmetrical Short-Circuit Faults
    Xue-Ping Gu and Zhi-Long Yang Department of Electric Power Engineering
    Journal of Electronic Science and Technology of China, 2008, (02) : 101 - 107
  • [42] Stability Analysis of Power System in Cape Verde with High Penetration Level of Wind Power under Short Circuit Fault
    Zhang, Yu
    Teixeira, Luis
    Kang, Yong
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [43] Dynamic deformation analysis of power transformer windings considering the influence of temperature on elasticity characteristics of winding materials under short circuit fault
    Wang, Shuang
    Wang, Shuhong
    Li, Hailin
    Yuan, Dongsheng
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2019, 59 (02) : 657 - 668
  • [44] Power Switch Open-Circuit Fault Diagnosis of Six-Phase Fault Tolerant Permanent Magnet Synchronous Motor System Under Normal and Fault-Tolerant Operation Conditions Using the Average Current Park's Vector Approach
    Guo, Hong
    Guo, Si
    Xu, Jinquan
    Tian, Xinlei
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (03) : 2641 - 2660
  • [45] Short-circuit Fault Current Analysis of AC Transmission Line of MMC-MTDC System for Wind Power Intergration
    Qin J.
    Jia K.
    Yang B.
    Chen J.
    Bi T.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (14): : 47 - 55
  • [46] A power switch open-circuit fault-tolerant scheme using dc current injection for dual active bridge converters in cascaded h-bridge solid-state transformer
    Zang, Jiajie
    Wang, Jiacheng
    Zhang, Jianwen
    Zhou, Jianqiao
    Shi, Gang
    Feng, Xin
    Zhang, Yixin
    IET POWER ELECTRONICS, 2023, 16 (07) : 1214 - 1226
  • [47] Double-layer rotor magnetic shield performance analysis in high temperature superconducting synchronous generators under short circuit fault conditions
    Hekmati, Arsalan
    Aliahmadi, Mehdi
    CRYOGENICS, 2016, 80 : 147 - 153
  • [48] Temperature field analysis and equal-amplitude temperature rise constraint current control method under open-circuit fault-tolerant operation for five-phase permanent magnet motor
    Jiang, Siyuan
    Gao, Mengzhen
    Niu, Junheng
    Feng, Haichao
    Ai, Liwang
    Xu, Xiaozhuo
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 202
  • [49] Dynamic Experiment for the Magnetothermal Stability of a 110 kV/3 kA Cold Dielectric High-Temperature Superconducting Cable With an Impact of Fault Current in Power System
    Zhu, Jiahui
    Zheng, Xiaodong
    Liu, Wei
    Chen, Panpan
    Li, Zhenming
    Zhang, Hongjie
    Qiu, Ming
    Yang, Wenjiang
    Rao, Shuangquan
    Fu, Shanshan
    Liu, Erwei
    Liu, Hongwei
    Yuan, Weijia
    Fang, Jin
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (04)
  • [50] Temperature and Pressure Distribution Simulations of 3-km-Long High-Temperature Superconducting Power Cable System With Fault Current for 66-kV-Class Transmission Lines
    Yasui, Tetsuo
    Takeda, Natsuko
    Yokoo, Yusuke
    Agatsuma, Koh
    Ishiyama, Atsushi
    Wang, Xudong
    Masuda, Takato
    Morimura, Toshiya
    Mimura, Tomoo
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)