Short circuit analysis of a fault-tolerant current-limiting high temperature superconducting transformer in a power system in presence of distributed generations

被引:1
|
作者
Sadeghi, Alireza [1 ]
Bonab, Shahin Alipour [1 ]
Song, Wenjuan [1 ]
Yazdani-Asrami, Mohammad [1 ]
机构
[1] Univ Glasgow, James Watt Sch Engn, Autonomous Syst & Connect Div, Prop Electrificat & Superconduct Grp, Glasgow City G12 8QQ, Scotland
来源
SUPERCONDUCTIVITY | 2024年 / 9卷
关键词
Fault Energy; Heat dissipation; Heat transfer; Insulation; Recovery Time; Temperature rise; AC LOSS; FLUX DIVERTORS; HTS;
D O I
10.1016/j.supcon.2024.100085
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power transformers are key elements for the safe and reliable delivery of electrical energy generated by renewable energy resources to consumers via transmission lines. Fault -tolerant current-limiting High Temperature Superconducting (FTCL HTS) transformers are type of superconducting transformers that tolerate fault for seconds and limit the fault current without the threat of burnout or delamination of tapes and deformation of windings. In this paper, the fault performance of a FTCL HTS transformer in a standard IEEE power system is investigated. The studied transformer is a 50 MVA 132 kV/13.8 kV transformer where both windings are made up of HTS tapes. The understudied power system consists of two microgrids with distributed generators. Part of the power in microgrids is supplied by the upstream grid which is connected to the microgrids through the HTS transformers. Two fault scenarios have been considered in this power system, in each one of these scenarios, a fault happens in one of the microgrids. Two considered fault scenarios have an approximate fault current of 18x to 23x of the rated current in the secondary windings. Results showed that insulated windings in FTCL HTS transformers could substantially reduce the peak temperature of the HTS windings, compared to bare windings. Afterwards, post -fault loading is imposed on the HTS windings, to observe their performance against the current increase after fault clearance. In this case, for the first scenario of the faults, the FTCL HTS transformer could tolerate 192% of post -fault overloading, while this number for the second fault scenario is 170%. Finally, the impact of post -fault loading on the full recovery time was discussed.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] The Effect of High-Temperature Superconducting Current Limiters on Short-Circuit Fault Clearing
    D. A. Grigor’ev
    O. Yu. Gusev
    Yu. P. Gusev
    N. O. Posokhov
    Thermal Engineering, 2023, 70 : 624 - 629
  • [22] Optimal Placement of Superconducting Fault Current Limiters (SFCLs) for Protection of an Electric Power System with Distributed Generations (DGs)
    Jo, Hyung-Chul
    Joo, Sung-Kwan
    Lee, Kisung
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [23] DG-integrated stochastic multiyear distribution expansion planning considering fault current-limiting high-temperature superconducting cables
    Shivaie, Mojtaba
    Dienel, Hans-Liudger
    Weinsier, Philip D.
    APPLIED ENERGY, 2023, 336
  • [24] Research on the Fault-Transient Characteristics of a DC Power System Considering the Cooperative Action of a Flexible Current-Limiting Device and a Circuit Breaker
    Zheng, Feng
    Peng, Yaling
    Wang, Weidong
    Zheng, Song
    SYMMETRY-BASEL, 2023, 15 (01):
  • [25] A fault control system using solid state circuit breakers and high temperature superconducting fault current limiters
    Hodges, B
    Dvorak, J
    Braun, C
    CONFERENCE RECORD OF THE 1996 TWENTY-SECOND INTERNATIONAL POWER MODULATOR SYMPOSIUM, 1996, : 232 - 234
  • [26] Short-Circuit Fault-Tolerant Topology for Multiport Cascaded DC/DC Converter in Photovoltaic Power Generation System
    Zhuang, Yizhan
    Liu, Fei
    Zhang, Xiangjing
    Huang, Yanhui
    Zha, Xiaoming
    Liu, Zhouyang
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (01) : 549 - 561
  • [27] Experimental analysis and circuit model of an inductive type high temperature superconducting fault current limiter
    Morandi, A
    Negrini, F
    Nitta, T
    Oshima, S
    Ribani, PL
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2000, 14 (25-27): : 3171 - 3176
  • [28] Development of high temperature superconducting fault current limiting transformer (HTC-SFCLT) with Bi2212 bulk coil
    Kurupakorn, C
    Hayakawa, N
    Kashima, N
    Nagaya, S
    Noe, M
    Juengst, KP
    Okubo, H
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) : 900 - 903
  • [29] Current Limiting Experiment of Transformer Type Superconducting Fault Current Limiter With Rewound Structure Using BSCCO Wire in Small Model Power System
    Oda, Sayaka
    Noda, Sho
    Nishioka, Hideyoshi
    Mori, Masato
    Baba, Jumpei
    Shirai, Yasuyuki
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 1307 - 1310
  • [30] Fault-Tolerant Control for Short-Circuit Fault of Power Switch in Dual-Winding Permanent-Magnet Motor Drive System
    Jiang, Xuefeng
    Gao, Yufei
    Wang, Shaoshuai
    Li, Yunzhi
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 810 - 814