Picosecond timing resolution with 3D trench silicon sensors

被引:0
|
作者
Borgato, F. [1 ,6 ]
Brundu, D. [2 ]
Cardini, A. [2 ]
Cossu, G. M. [2 ]
Dalla Betta, G. -F [5 ,8 ]
Garau, M. [2 ,7 ]
La Delfa, L. [2 ]
Lampis, A. [2 ,7 ]
Lai, A. [2 ]
Loi, A. [2 ]
Obertino, M. [4 ,9 ]
Vecchi, S. [3 ]
Simi, G. [1 ,6 ]
机构
[1] INFN X, Sez Padova, Padua, Italy
[2] INFN, Sez Cagliari, Cagliari, Italy
[3] INFN, Sez Ferrara, Ferrara, Italy
[4] INFN, Sez Torino, Turin, Italy
[5] INFN, TIFPA, Trento, Italy
[6] Univ Padua, Dipartimento Fis, Padua, Italy
[7] Univ Cagliari, Dipartimento Fis, Cagliari, Italy
[8] Univ Trento, Dipartimento Ingn Ind, Trento, Italy
[9] Univ Torino, Dipartimento Sci Agr & Forestali, Grugliasco, Italy
关键词
D O I
10.1393/ncc/i2023-23084-y
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In the high luminosity LHC phase, the collider will operate at a luminosity of 1.5 x 1034/cm/s and strict requirements will be posed on subdetectors capabilities. Concerning the LHCb Upgrade2 VELO, to guarantee a good detector performance, the additional information of the hit time stamping with an accuracy of at least 50 ps is needed. A very promising option today to achieve this level of timing precision is the 3D trench silicon pixel, developed by the INFN TimeSPOT collaboration. This kind of sensor would allow to build a 4D tracker, capable of excellent resolution in both space and time measurements. The latest beam test with the 3D trench sensors has been performed at the CERN SPS/H8 in 2021. By means of low-noise custom electronics boards featuring a two-stage transimpedance amplifier, it was possible to test silicon pixels and strips made with the 3D trench technology. To extrapolate the sensor time resolution, the crossing time of a particle was estimated using two MCP-PMTs as time tag, with an accuracy of approximately 7 ps. The beam-characterization was performed for both non-irradiated and irradiated (2.5 center dot 1016 1 MeV neq/cm2) devices. Preliminary results show that the standard deviation of the core of the pixels time distribution is about 10 ps and the tilted sensor has shown an efficiency close to 100%.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Performance of 3D trench silicon pixel sensors irradiated up to 1 • 1017 1 MeV n eq cm-2
    Lampis, A.
    Addison, M.
    Bellora, A.
    Boscardin, M.
    Brundu, D.
    Cardini, A.
    Cossu, G. M.
    Dalla Betta, G. F.
    La Delfa, L.
    Lai, A.
    Loi, A.
    Obertino, M.
    Ronchin, S.
    Vecchi, S.
    Verdoglia, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1069
  • [32] Timing-Optimised 3D Silicon Sensor with Columnar Electrode Geometry
    Loi, Angelo
    Lai, Adriano
    Ye, Jixing
    Dalla Betta, Gian-Franco
    SENSORS, 2025, 25 (03)
  • [33] Characterization of the 3D resolution of topometric sensors based on fringe and speckle pattern projection by a 3D transfer function
    Berssenbruegge, Philipp
    Dekiff, Markus
    Kemper, Bjoern
    Denz, Cornelia
    Dirksen, Dieter
    OPTICS AND LASERS IN ENGINEERING, 2012, 50 (03) : 465 - 472
  • [34] Development of 3D trenched-electrode pixel sensors with improved timing performance
    Forcolin, G. T.
    Mendicino, R.
    Boscardin, M.
    Lai, A.
    Loi, A.
    Ronchin, S.
    Vecchi, S.
    Dalla Betta, G-F
    JOURNAL OF INSTRUMENTATION, 2019, 14 (07):
  • [35] Signal processing for picosecond resolution timing measurements
    Genat, Jean-Francois
    Varner, Gary
    Tang, Fukun
    Frisch, Henry
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (02): : 387 - 393
  • [36] Logic analyzer delivers picosecond timing resolution
    Design News (Boston), 2000, 55 (08):
  • [37] Novel Formulations Containing Fluorescent Sensors to Improve the Resolution of 3D Prints
    Topa-Skwarczynska, Monika
    Swiezy, Andrzej
    Krok, Dominika
    Starzak, Katarzyna
    Niezgoda, Pawel
    Oksiuta, Bartosz
    Walczyk, Weronika
    Ortyl, Joanna
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (18)
  • [38] Beam test results of 3D silicon pixel sensors for future upgrades
    Nellist, C.
    Gligorova, A.
    Huse, T.
    Pacifico, N.
    Sandaker, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 141 - 145
  • [39] Hybrid Detectors of Neutrons Based on 3D Silicon Sensors with Polysiloxane Converter
    Dalla Betta, Gian-Franco
    Boscardin, Maurizio
    Carturan, Sara
    Cinausero, Marco
    Collazuol, Gianmaria
    Dalla Palma, Matteo
    Giacomini, Gabriele
    Gramegna, Fabiana
    Granja, Carlos
    Marchi, Tommaso
    Mendicino, Roberto
    Perillo, Ennio
    Povoli, Marco
    Quaranta, Alberto
    Ronchin, Sabina
    Slavicek, Tomas
    Stefanik, Milan
    Vacik, Jiri
    Zorzi, Nicola
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [40] Test beam results of 3D silicon pixel sensors for the ATLAS upgrade
    Grenier, P.
    Alimonti, G.
    Barbero, M.
    Bates, R.
    Bolle, E.
    Borri, M.
    Boscardin, M.
    Buttar, C.
    Capua, M.
    Cavalli-Sforza, M.
    Cobal, M.
    Cristofoli, A.
    G.-F. Dalla Betta
    Darbo, G.
    Da Via, C.
    Devetak, E.
    DeWilde, B.
    Di Girolamo, B.
    Dobos, D.
    Einsweiler, K.
    Esseni, D.
    Fazio, S.
    Fleta, C.
    Freestone, J.
    Gallrapp, C.
    Garcia-Sciveres, M.
    Gariano, G.
    Gemme, C.
    Giordani, M. -P.
    Gjersdal, H.
    Grinstein, S.
    Hansen, T.
    Hansen, T. -E.
    Hansson, P.
    Hasi, J.
    Helle, K.
    Hoeferkamp, M.
    Huegging, F.
    Jackson, P.
    Jakobs, K.
    Kalliopuska, J.
    Karagounis, M.
    Kenney, C.
    Koehler, M.
    Kocian, M.
    Kok, A.
    Kolya, S.
    Korokolov, I.
    Kostyukhin, V.
    Krueger, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 638 (01): : 33 - 40