A robust method for transmission line sequence parameter estimation using synchronized phasor measurements

被引:0
|
作者
Goklani, Hemantkumar [1 ]
Gajjar, Gopal [1 ]
Soman, S. A. [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Mumbai, India
关键词
Line parameter estimation; Percentage unbalance; Phasor measurement units (PMUs); INSTRUMENT TRANSFORMERS; CALIBRATION;
D O I
10.1016/j.epsr.2023.109616
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a positive and zero sequence line parameter estimation method, that is robust to systematic errors in the instrument transformers, especially when they are within the specified tolerance as per standards. Using Monte Carlo simulations, it is shown that the proposed approach is robust and accurate for all operating conditions, specifically for short length and lightly loaded transmission lines. We also validate the proposed approach on 400 kV and 765 kV transmission lines using actual field phasor measurement unit (PMU) data. Further, estimation of zero sequence line parameter values is somewhat tricky because not enough unbalance exists during the normal operation of the power grid. Therefore, we quantify the minimum percentage unbalance needed in currents to determine zero sequence line parameter values within 1% tolerance. We also present the line length and line loading effects in estimating zero sequence line parameter values using simulations. Simulation and field PMU data results on 765 kV and 400 kV lines of different lengths and loading levels show that the proposed method estimates accurate positive and zero sequence line parameter values.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Iterative Fault Location Scheme for a Transmission Line Using Synchronized Phasor Measurements
    Brahma, Sukumar M.
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2007, 8 (06):
  • [2] New fault-location method for a single multiterminal transmission line using synchronized phasor measurements
    Brahma, Sukumar M.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) : 1148 - 1153
  • [3] Synchronized phasor based on-line parameter identification of overhead transmission line
    Bi, Tianshu
    Chen, Jinmeng
    Wu, Jingtao
    Yang, Qixun
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1657 - 1662
  • [4] Accurate Kalman filter based estimation of transmission line parameters utilizing synchronized phasor measurements
    Moghanian, Mehrdad
    Dobakhshari, Ahmad Salehi
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 230
  • [5] On-line Estimation of Transmission Line Parameters Using Synchronized Measurements
    Al-Othman, Abdulrahman K.
    El-Naggar, Khaled M.
    AlSharidah, Michel E.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (02) : 233 - 239
  • [6] Multiarea state estimation using synchronized phasor measurements
    Zhao, L
    Abur, A
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (02) : 611 - 617
  • [7] A new state estimation using synchronized phasor measurements
    Cheng, Yunzhi
    Hu, Xiao
    Gou, Bei
    PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10, 2008, : 2817 - 2820
  • [8] Transmission Line Positive Sequence Impedance Estimation Based on Multiple Scans of Phasor Measurements
    Rubesa, Renata
    Kirincic, Vcdran
    Skok, Srdjan
    2014 IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON 2014), 2014, : 644 - 651
  • [9] SYNCHRONIZED PHASOR MEASUREMENTS FOR STATE ESTIMATION
    Gavrilas, Mihai
    Rusu, Ionut
    Gavrilas, Gilda
    Ivanov, Ovidiu
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2009, 54 (04): : 335 - 344
  • [10] Line Parameter Estimation using Phasor Measurements by the Total Least Squares Approach
    Dasgupta, Kalyan
    Soman, S. A.
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,