Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete-arch intraoral digital implant scans

被引:20
|
作者
Gomez-Polo, Miguel [1 ,2 ]
Cascos, Rocio [3 ]
Ortega, Rocio [4 ]
Barmak, Abdul B. [5 ]
Kois, John C. [6 ,7 ]
Revilla-Leon, Marta [8 ,9 ,10 ]
机构
[1] Univ Complutense Madrid, Sch Dent, Dept Conservat Dent & Prosthodont, Madrid, Spain
[2] Univ Complutense Madrid, Sch Dent, Postgrad Program Adv Implant Prosthodont, Madrid, Spain
[3] Univ Complutense Madrid, Sch Dent, Adv Implant Prosthodont, Madrid, Spain
[4] European Univ Madrid, Sch Dent, Dept Prosthet Dent, Madrid, Spain
[5] Univ Rochester, Eastman Inst Oral Hlth, Clin Res & Biostat, Med Ctr, Rochester, NY USA
[6] Univ Washington, Kois Ctr, Private Practice, Seattle, WA USA
[7] Univ Washington, Sch Dent, Grad Prosthodont, Seattle, WA USA
[8] Univ Washington, Sch Dent, Dept Restorat Dent, Grad Prosthodont, Seattle, WA 98195 USA
[9] Kois Ctr, Res & Digital Dent, Seattle, WA USA
[10] Tufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA USA
关键词
dental implants; intraoral scanners; scanning accuracy; scanning pattern; scanning strategy; IMPRESSIONS; SCANNERS; TRUENESS;
D O I
10.1111/clr.14069
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To measure the influence of arch location and scanning pattern on the accuracy, scanning time, and number of photograms of complete-arch implant scans acquired using an intraoral scanner (IOS).Materials and Methods A maxillary (maxillary group) and mandibular (mandibular group) model with 6 implant abutments on each cast was digitized using a desktop scanner (control scans). Six subgroups were created based on the scanning pattern used to acquire the scans using an IOS (Trios 4): occluso-buccal-lingual (OBL subgroup), occluso-linguo-buccal (OLB subgroup), bucco-linguo-occlusal (BLO subgroup), linguo-buccal-occlusal (LBO subgroup), zigzag (ZZ subgroup), and circumferential (C subgroup). The control scans were used as a reference to measure the discrepancy with the experimental scans calculating the root mean square error. Two-way ANOVA and the pairwise comparison Tukey tests were used to analyze the data (a = .05).Results Significant discrepancies in trueness (p < .001), precision (p < .001), scanning time (p < .001), and number of photograms (p < .001) were found. The maxillary group obtained poorer trueness and precision values, higher scanning times, and a larger number of photograms than the mandibular group. The C subgroup obtained the best trueness and precision values, but was not significantly different from the OLB, BLO, and LBO subgroups. The ZZ subgroup obtained the worst trueness and precision values (p < .05). The C subgroup obtained the lowest scanning time and number of photograms (p < .05).Conclusions Arch location and scanning pattern influenced scanning accuracy, scanning time, and number of photograms of complete-arch implant scans.
引用
收藏
页码:591 / 601
页数:11
相关论文
共 50 条
  • [41] Effect of artificial landmarks of the prefabricated auxiliary devices located at different arch positions on the accuracy of complete-arch edentulous digital implant scanning: An in-vitro study
    Wu, Hio Kuan
    Chen, Guanhui
    Zhang, Zhengchuan
    Lin, Xiaoxuan
    Huang, Xiaoqiong
    Deng, Feilong
    Li, Yiming
    JOURNAL OF DENTISTRY, 2024, 140
  • [42] Learning curve of digital intraoral optical scanning for complete arch: an in vitro study
    Lio, F.
    Carosi, P.
    Mazzetti, V
    Arcuri, C.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2022, 36 (02): : 19 - 27
  • [43] Techniques to improve the accuracy of complete arch implant intraoral digital scans: A systematic review
    Paratelli, Andrea
    Vania, Stefano
    Gomez-Polo, Cristina
    Ortega, Rocio
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06): : 844 - 854
  • [44] Comparison of the accuracy of intraoral scans between complete-arch scan and quadrant scan
    Youn-Gyeong Moon
    Kyung-Min Lee
    Progress in Orthodontics, 21
  • [45] Obtaining reliable intraoral digital scans for an implant-supported complete-arch prosthesis: A dental technique
    Iturrate, Mikel
    Minguez, Rikardo
    Pradies, Guillermo
    Solaberrieta, Eneko
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (02): : 237 - 241
  • [46] Influence of Scanning Strategies on the Accuracy of Digital Intraoral Scanning Systems
    Ender, A.
    Mehl, A.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2013, 16 (01) : 11 - 21
  • [47] Comparison of the accuracy of intraoral scans between complete-arch scan and quadrant scan
    Moon, Youn-Gyeong
    Lee, Kyung-Min
    PROGRESS IN ORTHODONTICS, 2020, 21 (01)
  • [48] Accuracy of six intraoral scanners for scanning complete-arch and 4-unit fixed partial dentures: An in vitro study
    Diker, Burcu
    Tak, Onjen
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (02): : 187 - 194
  • [49] Accuracy of Complete-Arch Scans Obtained by Intraoral Scanner and Smartphone Three-Dimensional Scanning Applications With Different Smartphone Position Setups: An In Vitro Study
    Jiang, Yuhao
    Long, Hu
    Soo, Suet Yeo
    Mavani, Hetal
    Tew, In Meei
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (06)
  • [50] Accuracy of intraoral scanning using modified scan bodies for complete arch implant-supported fixed prostheses
    Li, Yanxi
    Fang, He
    Yan, Yuwei
    Geng, Wei
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (05): : 994e1 - 994e8