Learning curve of digital intraoral optical scanning for complete arch: an in vitro study

被引:0
|
作者
Lio, F. [1 ]
Carosi, P. [1 ]
Mazzetti, V [1 ]
Arcuri, C. [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Chem Sci & Technol, Via Ric Sci 1, I-00133 Rome, Italy
关键词
Digital impression; complete arch; learning curve; accuracy; IMPRESSIONS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To evaluate the learning curve by unskilled operator for a complete arch digital impression in terms of scanning time and accuracy. MATERIALS AND METHODS: Three unskilled operators (OP1, OP2, and OP3) were enrolled to scan for 15 times each one an edentulous maxillary polymethylmethacrylate (PMMA) milled model with six implant analogs in different angulation and depth. The scanning times were recorded for each scan of the randomized sequence. The resulting 45 test files were aligned by the reference one, obtained by a high-precision industrial scanner. Each test file was processed with dedicated software to assess the linear (DX, DY, and DZ axis) deviations, that were summed up to obtain an average value of three-dimensional deviation. RESULTS: The three operators showed a mean scan time of 169.6 seconds (s), 217,9 s, 193,7 s respectively. Each operators show a statistically significant scan time reduction from the first to last scan: OP1 p=0,001; OP2 p=0,008; OP3 p=0,003. The average three-dimensional (3D) errors reported were OP1 133 microns (mm), OP2 111 mm and OP3 107 mm. Regarding the accuracy, a statistically significant reduction in the average 3D error was reported: OP1 p = 0.02; OP2 p = 0.04; OP3 p = 0.04. CONCLUSION: Within the limitation of this in vitro study, it seems to be that the repetitive use of IOS significatively affects the investigated variables in an overall scanning time reduction and scan accuracy enhancement.
引用
收藏
页码:19 / 27
页数:9
相关论文
共 50 条
  • [1] Learning curve of digital intraoral scanning - an in vivo study
    Roth, Ivett
    Czigola, Alexandra
    Joos-Kovacs, Gellert Levente
    Dalos, Magdolna
    Hermann, Peter
    Borbely, Judit
    BMC ORAL HEALTH, 2020, 20 (01)
  • [2] Learning curve of digital intraoral scanning – an in vivo study
    Ivett Róth
    Alexandra Czigola
    Gellért Levente Joós-Kovács
    Magdolna Dalos
    Péter Hermann
    Judit Borbély
    BMC Oral Health, 20
  • [3] The role of artificial intelligence in intraoral scanning for complete-arch digital impressions: An in vitro study
    Roth, Ivett
    Geczi, Zoltan
    Vegh, Daniel Csaba
    Hegedus, Tamas
    Pal, Adrienn
    Hermann, Peter
    Schmalzl, Judit
    JOURNAL OF DENTISTRY, 2025, 156
  • [4] Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study
    Pozzi, Alessandro
    Agliardi, Enrico
    Lio, Fabrizio
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 172 - 180
  • [5] Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study
    Pozzi, Alessandro
    Carosi, Paolo
    Gallucci, German O.
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (10) : 1106 - 1117
  • [6] Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An in vitro study
    Meneghetti, Priscila Ceolin
    Li, Junying
    Borella, Paulo Sergio
    Mendonca, Gustavo
    Burnett Jr, Luiz Henrique
    PLOS ONE, 2023, 18 (12):
  • [7] Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete-arch intraoral digital implant scans
    Gomez-Polo, Miguel
    Cascos, Rocio
    Ortega, Rocio
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (06) : 591 - 601
  • [8] Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: an in vitro study
    Passos, Leandro
    Meiga, Sergio
    Brigagao, Vinicius
    Street, Alexandre
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (04) : 307 - 319
  • [9] Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study
    Celeghin, Giordano
    Franceschetti, Giulio
    Mobilio, Nicola
    Fasiol, Alberto
    Catapano, Santo
    Corsalini, Massimo
    Grande, Francesco
    HEALTHCARE, 2021, 9 (03)
  • [10] Error propagation from intraoral scanning to additive manufacturing of complete-arch dentate models: An in vitro study
    Auskalnis, Liudas
    Akulauskas, Mykolas
    Jegelevicius, Darius
    Simonaitis, Tomas
    Rutkunas, Vygandas
    JOURNAL OF DENTISTRY, 2022, 121