Deep inspiratory breath hold assisted by continuous positive airway pressure ventilation for lung stereotactic body radiotherapy

被引:3
|
作者
Appel, S. [1 ,2 ]
Lawrence, Y. R. [1 ,2 ]
Bar, J. [2 ,3 ]
Jacobson, G. [1 ,2 ]
Marom, E. M. [2 ,4 ]
Katzman, T. [1 ,2 ]
Ben-Ayun, M. [1 ,2 ]
Dubinski, S. [1 ,2 ]
Haisraely, O. [1 ,2 ]
Weizman, N. [5 ]
Davidson, T. [6 ]
Weiss, I. [1 ,2 ]
Mansano, A. [1 ,2 ]
Goldstein, J. D. [7 ]
Symon, Z. [1 ,2 ]
机构
[1] Sheba Med Ctr, Dept Radiat Oncol, Tel Hashomer, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[3] Sheba Med Ctr, Inst Oncol, Tel Hashomer, Israel
[4] Sheba Med Ctr, Dept Radiol, Tel Hashomer, Israel
[5] Hadassah Med Ctr, Dept Radiat Oncol, Jerusalem, Israel
[6] Sheba Med Ctr, Nucl Med, Tel Hashomer, Israel
[7] Ichilov Hosp, Dept Radiat Oncol, Tel Aviv, Israel
来源
CANCER RADIOTHERAPIE | 2023年 / 27卷 / 01期
关键词
CONE-BEAM CT; RADIATION-THERAPY SBRT; MOTION MANAGEMENT; EARLY-STAGE; ABLATIVE RADIOTHERAPY; RESPIRATORY MOTION; TUMORS; CANCER; IMMOBILIZATION; IMPACT;
D O I
10.1016/j.canrad.2022.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. - Continuous positive airway pressure (CPAP) ventilation hyperinflates the lungs and reduces diaphragmatic motion. We hypothesized that CPAP could be safely combined with deep inspiratory breath hold (CPAP-DIBH) during lung stereotactic radiotherapy (SBRT). Material and methods. - Patients with stage-1 lung cancer or lung metastasis treated with CPAP-DIBH SBRT between 3/20175/2021 were analyzed retrospectively. Patient characteristics, treatment parameters, duration of breath holds in all sessions and tolerance to CPAP-DIBH were recorded. Local control (LC) was assessed from CT or PET-CT imaging. The distances between the tumor and mediastinal organs at risk (OAR) in centrally located tumors using either free breathing (FB) or CPAP-DIBH were compared. Toxicity was graded retrospectively. Results. - Forty-five patients with 71 lesions were treated with CPAP-DIBH SBRT. Indications for CPAP-DIBH were prior radiation (35/71, 65%), lower lobe location (34/71, 48%), multiple lesions (26/71, 36.6%) and proximity to mediastinal OAR (7/71, 10%). Patient characteristics were: F:M 43%: 57%; mean gross tumor volume 4.5 cm3 (SD 7.9), mean planning target volume 20 cm3 (SD 27), primary: metastatic lesions (7%:93%). Mean radiation dose was 52.5 Gray (SD3.5). Mean lung volume was 5292 cm3 (SD 1106). Mean duration of CPAP-DIBH was 41.3 s (IQR 3146.8). LC at 2 years was 89.5% (95% CI 7695.5). In patients with central lesions, the distance between the tumor and mediastinal OAR increased from 0.84 cm (SD 0.65) with FB to 1.23 cm (SD 0.8) with CPAP-DIBH (p = 0.002). Most patients tolerated CPAP well and completed all treatments after starting therapy. Three patients did not receive treatment: 2 were unable to tolerate CPAP and 1 had syncope (pre-existing). Toxicity was grade 2 in 4/65 (6%) and grade 3 in 1/65 (1.5%). There was no grade 2 or higher esophageal or tracheal toxicities. Conclusion. - CPAP-DIBH assisted lung SBRT was tolerated well and was associated with minimal toxicity and favorable LC. This technique may be considered when treating multiple lung lesions, lesions located in the lower lobes or adjacent to mediastinal OAR. (c) 2022 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 50 条
  • [21] A Pilot Study to Evaluate Percussive Ventilation Breath Hold to Improve Lung Stereotactic Ablative Radiotherapy (PVB-SABR)
    Mai, W. X.
    Swamy, A.
    Flores, K. Z.
    Langer, J.
    Free, D.
    Gebeyehu, P.
    Skinner, L.
    Wong, S.
    Huang, K. Z.
    Pranoto, A.
    Lao, O.
    Loo, B. W., Jr.
    Blomain, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E45 - E46
  • [22] Feasibility and tolerability of breath-hold in liver stereotactic body radiotherapy with surface guided radiotherapy
    Turna, Menekse
    Kucukmorkoc, Esra
    Rzazade, Rashad
    Canoglu, Mehmet Dogu
    Kucuk, Nadir
    Caglar, Hale Basak
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2023, 28
  • [23] Cardiac and lung sparing radiotherapy in breast and chest wall irradiation with surface guided radiotherapy using deep inspiratory breath hold technique
    Bellala, R. S.
    ANNALS OF ONCOLOGY, 2022, 33 : S1437 - S1437
  • [24] Intrafraction target shift comparison using two breath-hold systems in lung stereotactic body radiotherapy
    Prado, Alejandro
    Zucca, Daniel
    De la Casa, Miguel Angel
    Marti, Jaime
    Alonso, Leyre
    de Acilu, Paz Garcia
    Garcia, Juan
    Hernando, Ovidio
    Fernandez-Leton, Pedro
    Rubio, Carmen
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 57 - 62
  • [25] Evaluating intra-fractional tumor motion in lung stereotactic radiotherapy with deep inspiration breath-hold
    Fu, Weihua
    Zhang, Yongqian
    Mehta, Kiran
    Chen, Alex
    Musunuru, Hima Bindu
    Pucci, Pietro
    Kubis, Jason
    Huq, M. Saiful
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [26] Continuous Positive Airway Pressure versus Differential Lung Ventilation during One Lung Ventilation for Thoracic Surgery
    Purayil, Aswathy Puthan
    Nair, Suresh Gangadharan
    Abraham, Jobin
    Vazhakatt, Joel Devasia
    Rajmohan, Nisha
    Shaji, Anupama
    ANNALS OF CARDIAC ANAESTHESIA, 2024, 27 (03) : 235 - 240
  • [27] Continuous Positive Airway Pressure versus Differential Lung Ventilation during One Lung Ventilation for Thoracic Surgery
    Patil, Bhakti R.
    Panidapu, Nagarjuna
    Neema, Praveen K.
    ANNALS OF CARDIAC ANAESTHESIA, 2025, 28 (01) : 95 - 96
  • [28] STIMULATION OF INSPIRATORY ACTIVITY DURING CONTINUOUS POSITIVE AIRWAY PRESSURE
    NORSTED, T
    JONZON, A
    SEDIN, G
    PEDIATRIC RESEARCH, 1984, 18 (01) : 89 - 89
  • [29] Optimizing target and diaphragmatic configuration, and dosimetric benefits using continuous positive airway pressure in stereotactic ablative radiotherapy for lung tumors
    Park, Jung Bin
    Lee, Joo Ho
    Chang, Ji Hyun
    Son, Jaeman
    Kwon, Seho
    Choi, Su Yun
    Shin, Hyun-Woo
    Yu, Tosol
    Kim, Hak Jae
    RADIATION ONCOLOGY JOURNAL, 2024, 42 (03): : 200 - 209
  • [30] Reproducibility of surface-based deep inspiration breath-hold technique for lung stereotactic body radiotherapy on a closed-bore gantry linac
    Nguyen, Daniel
    Reinoso, Rebeca
    Farah, Jad
    Yossi, Sena
    Lorchel, Fabrice
    Passerat, Victor
    Louet, Estelle
    Pouchard, Isabelle
    Khodri, Mustapha
    Barbet, Nicolas
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 26