Analysis of Reported Adverse Events Related to Over-the-Scope Clips: A MAUDE Database Analysis

被引:2
|
作者
Abbas, Daniyal [1 ]
Abdallah, Mohamed [2 ]
Ahmed, Khalid [3 ]
Abdalla, Abubaker O. [4 ]
Mcdonald, Nicholas [2 ]
Umar, Shifa [5 ]
Hanson, Brian J. [2 ]
Bilal, Mohammad [2 ,6 ]
机构
[1] East Carolina Univ, Dept Internal Med, Greenville, NC USA
[2] Univ Minnesota, Dept Med, Div Gastroenterol Hepatol & Nutr, Minneapolis, MN USA
[3] Wright Ctr Community Hlth, Dept Internal Med, Scranton, PA USA
[4] Emory Univ, Div Gastroenterol & Hepatol, Atlanta, GA USA
[5] Mayo Clin, Dept Gastroenterol & Hepatol, Rochester, MN USA
[6] Div Gastroenterol Hepatol & Nutr, 406 Harvard St SE, MMC36, Minneapolis, MN 55455 USA
来源
TECHNIQUES AND INNOVATIONS IN GASTROINTESTINAL ENDOSCOPY | 2023年 / 25卷 / 02期
关键词
Over-the-scope clip; Adverse events; MAUDE database; Endoscopic closure; DUODENAL PERFORATION; ENDOSCOPIC TREATMENT; CLOSURE; SYSTEM; DEVICE; EXPERIENCE; FISTULAS; OVESCO; TRACT;
D O I
10.1016/j.tige.2022.11.005
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND AND AIMS: Over-the-scope clips (OTSCs) have been increasingly used in the management of bleeding, perforations, fistulae, and anastomotic leaks in the gastrointestinal tract. However, since their Food and Drug Administration (FDA) approval in 2010, data on the adverse events of OTSC systems have been lacking. The aim of our study was to report and analyze adverse events and device failures associated with OTSC systems using the FDA's Manufacturer and User Facility Device Experience (MAUDE) database.METHODS: We analyzed the FDA MAUDE database post-marketing surveillance data from January 2013 through May 2022 on the two OTSC systems available in the United States.RESULTS: Forty medical device reporting claims were found from January 2013 through May 2022. Adverse events were classified as device-related problems and patient-related adverse events. Forty device-related problems were reported, along with 20 device-related adverse events. Most device related problems were reported in the Padlock defect closure system (n = 23), followed by the Padlock pro clip system (n = 8) and Ovesco OTSC system (n = 9). The most common device-related problem was related to the failure of OTSC deployment (n = 13), followed by material protrusion or extrusion (n = 7). The most common patient adverse events were perforation (n = 4), esophageal laceration (n = 4), bleeding (n = 3), and luminal stenosis (n = 3). All 4 patients required surgical management of the perforation. No deaths related to the use of OTSCs were reported.CONCLUSION: Failure of OTSC deployment and perforation were the most common device-related problem and patient-related adverse event, respectively. As the use of OTSC systems continues to increase, it is important for endoscopists to be mindful of both the common and rare adverse events associated with OTSC use.
引用
收藏
页码:106 / 112
页数:7
相关论文
共 50 条
  • [31] ADVERSE EVENTS ASSOCIATED WITH SYNTHETIC MALE SLINGS: AN ANALYSIS OF THE FDA MAUDE DATABASE
    Zhao, Hanson
    Souders, Colby P.
    Dallas, Kai
    Kuhlmann, Paige
    Eilber, Karyn
    Anger, Jennifer T.
    JOURNAL OF UROLOGY, 2020, 203 : E585 - E585
  • [32] Adverse events associated with synthetic male slings: an analysis of the fda maude database
    Zhao, Hanson
    Souders, Colby P.
    Dallas, Kai
    Kuhlmann, Paige
    Eilber, Karyn
    Anger, Jennifer T.
    NEUROUROLOGY AND URODYNAMICS, 2020, 39 : S73 - S74
  • [33] ADVERSE EVENTS OF THE SPYGLASS™ SINGLE OPERATOR CHOLANGIOSCOPY SYSTEM: A MAUDE DATABASE ANALYSIS
    Chandan, Saurabh
    Ramai, Daryl
    Mozell, Daniel
    Mohan, Babu
    Facciorusso, Antonio
    Diehl, David
    Kochhar, Gursimran
    GASTROINTESTINAL ENDOSCOPY, 2024, 99 (06) : AB649 - AB649
  • [34] ADVERSE EVENTS ASSOCIATED WITH THE DAVINCI SURGICAL SYSTEM AS REPORTED IN THE FDA MAUDE DATABASE
    Gupta, Priyanka
    Schomburg, John
    Lund, Erik
    Adejoro, Olukawayode
    Konety, Badrinath
    JOURNAL OF UROLOGY, 2013, 189 (04): : E351 - E351
  • [35] Clinical Adverse Events Associated With Bravo pH Monitors: A MAUDE Database Analysis
    Bhandari, Peter
    Buckley, Megan C.
    Ramai, Daryl
    Cheung, Mary
    Swaminath, Arun
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2022, 117 (10): : S431 - S431
  • [36] Analysis of Reported Adverse Events Related to Hemospray
    Ahmed, Khalid
    Abdallah, Mohamed
    Abbas, Daniyal
    Jaber, Fouad
    Abdalla, Abubaker O.
    Mohamed, Mouhand
    Mcdonald, Nicholas
    Hanson, Brian J.
    Bilal, Mohammad
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2024, 58 (04) : 402 - 406
  • [37] A COMPREHENSIVE ANALYSIS OF REPORTED ADVERSE EVENTS WITH BILIARY SELF-EXPANDING METAL STENTS: AN FDA MAUDE DATABASE STUDY
    Patel, Pratik
    Ali, Hassam
    Moond, Vishali
    Jaber, Fouad
    Dahiya, Dushyant Singh
    Sarfraz, Shiza
    Chuang, Justin
    Adler, Douglas G.
    GASTROENTEROLOGY, 2024, 166 (05) : S1044 - S1044
  • [38] Applicability, efficacy, and safety of over-the-scope clips in children
    Sharma, Shishu
    Barakat, Monique
    Urs, Arun
    Campbell, David
    Rao, Prithviraj
    Schluckebier, Dominique
    Gugig, Roberto
    Thomson, Mike
    GASTROINTESTINAL ENDOSCOPY, 2022, 95 (03) : 489 - 499
  • [39] Efficacy and safety of over-the-scope clips for gastrointestinal bleeding: a systematic review and meta-analysis
    Chandrasekar, Viveksandeep Thoguluva
    Desai, Madhav
    Aziz, Muhammad
    Patel, Harsh K.
    Gorrepati, Venkata Subhash
    Jegadeesan, Ramprasad
    Rai, Tarun
    Sathyamurthy, Anjana
    Murino, Alberto
    Hassan, Cesare
    Repici, Alessandro
    Sharma, Prateek
    ENDOSCOPY, 2019, 51 (10) : 941 - 949
  • [40] A characterization and disproportionality analysis of medication error related adverse events reported to the FAERS database
    Carnovale, Carla
    Mazhar, Faizan
    Pozzi, Marco
    Gentili, Marta
    Clementi, Emilio
    Radice, Sonia
    EXPERT OPINION ON DRUG SAFETY, 2018, 17 (12) : 1161 - 1169