Diagnostic value of liver contrast-enhanced ultrasound in early hepatocellular carcinoma: a systematic review and meta-analysis

被引:4
|
作者
Zhang, Zhilan [1 ]
Ma, Chunyan [1 ]
Luo, Yanbing [1 ,2 ]
机构
[1] Cent South Univ, Haikou Hosp, Xiangya Sch Med, Dept Ultrason Med, Haikou, Peoples R China
[2] Cent South Univ, Haikou Hosp, Xiangya Sch Med, Dept Ultrason Med, 43 Renmin Ave, Haikou 570208, Peoples R China
关键词
Contrast-enhanced ultrasound (CEUS); hepatocellular carcinoma; early stage; diagnosis; meta-analysis;
D O I
10.21037/jgo-23-211
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Hepatocellular carcinoma is the sixth most common cancer in the world, and its incidence rate will continue to increase. Contrast-enhanced ultrasound (CEUS) is feasible as a rapid examination for early hepatocellular carcinoma diagnosis. However, considering the possible causes of false positives caused by ultrasound, its diagnostic value is still controversial. Therefore, the study conducted a meta-analysis to evaluate the application value of CEUS in the early diagnosis of hepatocellular carcinoma. Knowledge Infrastructure (CNKI), Chongqing VIP Information (VIP), and Wanfang databases were searched to retrieve articles on the use of CEUS for the early diagnosis of hepatocellular carcinoma. The literature quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) quality assessment tool. The meta-analysis was performed using STATA 17.0 to fit the likelihood ratio (NLR), diagnostic odds ratio (DOR), and corresponding 95% CI, summary receiver operating characteristic curves (SROC), area under the curve (AUC), and 95% confidence interval (CI). The publication bias of the included literature was evaluated using the DEEK funnel plot.Results: Ultimately, 9 articles, comprising 1,434 patients, were included in the meta-analysis. The heterogeneity test found that I2>50%, using a random effects model. The results of the meta-analysis showed that the CEUS had a combined sensitivity of 0.92 (95% CI: 0.86-0.95), a combined specificity of 0.93 (95% CI: 0.56-0.99), a combined PLR of 13.47 (95% CI: 1.51-120.46), a combined NLR of 0.09 (95% CI: 0.05-0.14), a combined DOR of 154.16 (95% CI: 15.93-1,492.02), a diagnostic score of 5.04 (95% CI: 2.77- 7.31), and a combined AUC of 0.95 (95% CI: 0.93-0.97). The correlation coefficient of the threshold-effect analysis was 0.13 (P>0.05). The results of the regression analysis showed that the country of publication (P=0.14) and the size of the lesion nodules (P=0.46) were not sources of heterogeneity.Conclusions: Liver CEUS has an advantage in the early diagnosis of hepatocellular carcinoma, with high sensitivity and specificity, and has clinical application value.
引用
收藏
页码:626 / 635
页数:10
相关论文
共 50 条
  • [21] Contrast-enhanced Mammography: A Systematic Review and Meta-Analysis of Diagnostic Performance
    Cozzi, Andrea
    Magni, Veronica
    Zanardo, Moreno
    Schiaffino, Simone
    Sardanelli, Francesco
    RADIOLOGY, 2022, 302 (03) : 568 - 581
  • [22] Diagnostic Test Accuracy of Contrast-Enhanced Ultrasound With Sonazoid for Assessment of Focal Liver Lesions: A Systematic Review and Meta-Analysis
    Tang, Yongqing
    Sasaki, Shun-ichi
    Hawley, Joshua
    Peillon, Aurelie
    Sjostrom, Anders
    Fuentes-Alburo, Adolfo
    Tranquart, Francois
    JOURNAL OF CLINICAL ULTRASOUND, 2025, 53 (03) : 510 - 524
  • [23] Dynamic contrast enhanced ultrasound in differential diagnosis of hepatocellular carcinoma: A systematic review and meta-analysis
    Esposto, Giorgio
    Santini, Paolo
    Termite, Fabrizio
    Galasso, Linda
    Mignini, Irene
    Ainora, Maria Elena
    Gasbarrini, Antonio
    Zocco, Maria Assunta
    WORLD JOURNAL OF GASTROINTESTINAL ONCOLOGY, 2024, 16 (06) : 2804 - 2815
  • [24] Contrast-enhanced ultrasound liver imaging reporting and data system for diagnosing hepatocellular carcinoma: A meta-analysis
    Shin, Jaeseung
    Lee, Sunyoung
    Bae, Heejin
    Chung, Yong Eun
    Choi, Jin-Young
    Huh, Yong-Min
    Park, Mi-Suk
    LIVER INTERNATIONAL, 2020, 40 (10) : 2345 - 2352
  • [25] Diagnostic accuracy of contrast-enhanced ultrasound for renal cell carcinoma: a meta-analysis
    Wang, Cong
    Yu, Chong
    Yang, Fang
    Yang, Guang
    TUMOR BIOLOGY, 2014, 35 (07) : 6343 - 6350
  • [26] Meta-analysis of the diagnostic value of contrast-enhanced ultrasound for the detection of vascular complications after liver transplantation
    Chen, Suxian
    Wang, Xiong
    Zhang, Baoxin
    Liu, Beijing
    Pan, Hui
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2019, 111 (05) : 388 - 396
  • [27] Diagnostic value of contrast-enhanced ultrasound for the depth of myometrial infiltration in early endometrial cancer: a meta-analysis
    Li, Siqi
    Liang, Yingying
    Wang, Jiaxun
    FRONTIERS IN ONCOLOGY, 2025, 15
  • [28] Contrast-enhanced ultrasound versus conventional ultrasound in guided liver puncture biopsy: a systematic review and meta-analysis
    Yang, Lidan
    Zhang, Ting
    Wang, Lei
    Du, Juan
    Zhang, Hao
    Yi, Wenquan
    MEDICAL ULTRASONOGRAPHY, 2024, 26 (03) : 301 - 309
  • [29] Diagnostic Performance of Contrast-Enhanced Ultrasound in the Evaluation of Small Renal Masses: A Systematic Review and Meta-Analysis
    Tufano, Antonio
    Antonelli, Luca
    Di Pierro, Giovanni Battista
    Flammia, Rocco Simone
    Minelli, Rocco
    Anceschi, Umberto
    Leonardo, Costantino
    Franco, Giorgio
    Drudi, Francesco Maria
    Cantisani, Vito
    DIAGNOSTICS, 2022, 12 (10)
  • [30] Accuracy of Various Forms of Contrast-Enhanced MRI for Diagnosing Hepatocellular Carcinoma: A Systematic Review and Meta-Analysis
    Zhao, Chun
    Dai, Hongyan
    Shao, Juwei
    He, Qian
    Su, Wei
    Wang, Peng
    Tang, Qiuyue
    Zeng, Junren
    Xu, Song
    Zhao, Juanjuan
    Xiang, Shutian
    FRONTIERS IN ONCOLOGY, 2021, 11