Motion-robust, multi-slice, real-time MR thermometry for MR-guided thermal therapy in abdominal organs

被引:3
|
作者
Kim, Kisoo [1 ,3 ]
Diederich, Chris [2 ]
Narsinh, Kazim [1 ]
Ozhinsky, Eugene [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USA
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
[3] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 2340 Sutter St,S341, San Francisco, CA 94115 USA
关键词
MR thermometry; abdominal organ; motion; real-time MR imaging; MR-guided thermal therapy; MAGNETIC-RESONANCE THERMOMETRY; INTENSITY FOCUSED ULTRASOUND; IN-VIVO; ABLATION; HYPERTHERMIA; REFERENCELESS; GUIDANCE;
D O I
10.1080/02656736.2022.2151649
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop an effective and practical reconstruction pipeline to achieve motion-robust, multi-slice, real-time MR thermometry for monitoring thermal therapy in abdominal organs. Methods: The application includes a fast spiral magnetic resonance imaging (MRI) pulse sequence and a real-time reconstruction pipeline based on multi-baseline proton resonance frequency shift (PRFS) method with visualization of temperature imaging. The pipeline supports multi-slice acquisition with minimal reconstruction lag. Simulations with a virtual motion phantom were performed to investigate the influence of the number of baselines and respiratory rate on the accuracy of temperature measurement. Phantom experiments with ultrasound heating were performed using a custom-made motion phantom to evaluate the performance of the pipeline. Lastly, experiments in healthy volunteers (N= 2) without heating were performed to evaluate the accuracy and stability of MR thermometry in abdominal organs (liver and kidney). Results: The multi-baseline approach with greater than 25 baselines resulted in minimal temperature errors in the simulation. Phantom experiments demonstrated a 713ms update time for 3-slice acquisitions. Temperature maps with 30 baselines showed clear temperature distributions caused by ultrasound heating in the respiratory phantom. Finally, the pipeline was evaluated with physiologic motions in healthy volunteers without heating, which demonstrated the accuracy (root mean square error [RMSE]) of 1.23 +/- 0.18 degrees C (liver) and 1.21 7 +/- 0.17 degrees C (kidney) and precision of 1.13 +/- 0.11 degrees C (liver) and 1.16 +/- 0.15 degrees C (kidney) using 32 baselines. Conclusions: The proposed real-time acquisition and reconstruction pipeline allows motion-robust, multi-slice, real-time temperature monitoring within the abdomen during free breathing.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Evaluation of Real-Time Cine Imaging During MLC and Gantry Motion for MR-Guided Radiation Therapy
    Kielbasa, J.
    Meeks, S.
    Kelly, P.
    Willoughby, T.
    Zeidan, O.
    Shah, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E615 - E615
  • [12] A system for advanced real-time visualization and monitoring of MR-guided thermal ablations
    Rothgang, Eva
    Gilson, Wesley D.
    Hornegger, Joachim
    Lorenz, Christine H.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [13] Technical Challenges of Real-Time Adaptive MR-Guided Radiotherapy
    Thorwarth, Daniela
    Low, Daniel A.
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [14] Real-Time Catheter Tracking and Visualization in MR-Guided Brachytherapy
    Wang, W.
    Gao, Y.
    Mehrtash, A.
    Seethmaraju, R.
    Kapur, T.
    Vishwanathan, A.
    Schmidt, E.
    Cormack, R.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [15] Real-time motion monitoring using orthogonal cine MRI during MR-guided adaptive radiation therapy for abdominal tumors on 1.5T MR-Linac
    Jassar, Hassan
    Tai, An
    Chen, Xinfeng
    Keiper, Timothy D. D.
    Paulson, Eric
    Lathuiliere, Fabienne
    Beriault, Silvain
    Hebert, Francois
    Savard, Laurence
    Cooper, David T. T.
    Cloake, Sneha
    Li, X. Allen
    MEDICAL PHYSICS, 2023, 50 (05) : 3103 - 3116
  • [16] Real-time multi-resolution image reconstruction for MR-guided prostate radiotherapy
    Borman, P.
    Bruijnen, T.
    Schakel, T.
    Raaymakers, B.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S518 - S519
  • [17] Impact of Intrafractional Changes of Abdominal Gas Cavities in MR-guided Adaptive Radiation Therapy: Is Real-time Adaptation Necessary?
    Keiper, T.
    Tai, A.
    Mickevicius, N.
    Lim, S. N.
    Chen, X.
    Paulson, E. S.
    Klawikowski, S.
    Zhong, H.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E751 - E752
  • [18] MR-Guided Radiotherapy (MRgRT) for Laryngeal Cancer With Real-Time Visualization of Intrafraction Larynx Motion
    Autrey, C. M.
    Mittauer, K. E.
    Alvarez, D.
    Chuong, M. D.
    Contreras, J.
    Gutierrez, A.
    Kaiser, A.
    McCulloch, J.
    Romaguera, T.
    Kalman, N. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E530 - E531
  • [19] Real-Time Spinal Cord Motion Tracking for MR-guided Spine SBRT (A Pilot Study)
    Ding, Y.
    Yeboa, D. N.
    Yang, J.
    Wang, J.
    Cloake, S.
    Lathuiliere, F.
    Lessard, E.
    Seithel, M.
    Han, E. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E671 - E671
  • [20] An improved optical flow tracking technique for real-time MR-guided beam therapies in moving organs
    Zachiu, C.
    Papadakis, N.
    Ries, M.
    Moonen, C.
    de Senneville, B. Denis
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (23): : 9003 - 9029