Motion-robust, multi-slice, real-time MR thermometry for MR-guided thermal therapy in abdominal organs

被引:3
|
作者
Kim, Kisoo [1 ,3 ]
Diederich, Chris [2 ]
Narsinh, Kazim [1 ]
Ozhinsky, Eugene [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA USA
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
[3] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 2340 Sutter St,S341, San Francisco, CA 94115 USA
关键词
MR thermometry; abdominal organ; motion; real-time MR imaging; MR-guided thermal therapy; MAGNETIC-RESONANCE THERMOMETRY; INTENSITY FOCUSED ULTRASOUND; IN-VIVO; ABLATION; HYPERTHERMIA; REFERENCELESS; GUIDANCE;
D O I
10.1080/02656736.2022.2151649
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop an effective and practical reconstruction pipeline to achieve motion-robust, multi-slice, real-time MR thermometry for monitoring thermal therapy in abdominal organs. Methods: The application includes a fast spiral magnetic resonance imaging (MRI) pulse sequence and a real-time reconstruction pipeline based on multi-baseline proton resonance frequency shift (PRFS) method with visualization of temperature imaging. The pipeline supports multi-slice acquisition with minimal reconstruction lag. Simulations with a virtual motion phantom were performed to investigate the influence of the number of baselines and respiratory rate on the accuracy of temperature measurement. Phantom experiments with ultrasound heating were performed using a custom-made motion phantom to evaluate the performance of the pipeline. Lastly, experiments in healthy volunteers (N= 2) without heating were performed to evaluate the accuracy and stability of MR thermometry in abdominal organs (liver and kidney). Results: The multi-baseline approach with greater than 25 baselines resulted in minimal temperature errors in the simulation. Phantom experiments demonstrated a 713ms update time for 3-slice acquisitions. Temperature maps with 30 baselines showed clear temperature distributions caused by ultrasound heating in the respiratory phantom. Finally, the pipeline was evaluated with physiologic motions in healthy volunteers without heating, which demonstrated the accuracy (root mean square error [RMSE]) of 1.23 +/- 0.18 degrees C (liver) and 1.21 7 +/- 0.17 degrees C (kidney) and precision of 1.13 +/- 0.11 degrees C (liver) and 1.16 +/- 0.15 degrees C (kidney) using 32 baselines. Conclusions: The proposed real-time acquisition and reconstruction pipeline allows motion-robust, multi-slice, real-time temperature monitoring within the abdomen during free breathing.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Real-Time Method for Motion-Compensated MR Thermometry and MRgHIFU Treatment in Abdominal Organs
    Celicanin, Zarko
    Auboiroux, Vincent
    Bieri, Oliver
    Petrusca, Lorena
    Santini, Francesco
    Viallon, Magalie
    Scheffler, Klaus
    Salomir, Rares
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) : 1087 - 1095
  • [2] Real-Time MR-Thermometry and Dosimetry for Interventional Guidance on Abdominal Organs
    Roujol, Sebastien
    Ries, Mario
    Quesson, Bruno
    Moonen, Chrit
    de Senneville, Baudouin Denis
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 1080 - 1087
  • [3] Dosimetric Assessment for Real-Time Anatomical Motion during MR-Guided Radiation Therapy by MR-LINAC
    Chen, X.
    Oh, S.
    Hwang, M. S.
    Lee, D.
    Fuhrer, R.
    Kirichenko, A. V.
    Renz, P. B.
    Sohn, J. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E589 - E591
  • [4] MR-Guided Thermotherapy of Abdominal Organs Using a Robust PCA-Based Motion Descriptor
    de Senneville, Baudouin Denis
    Ries, Mario
    Maclair, Gregory
    Moonen, Chrit
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (11) : 1987 - 1995
  • [5] Feasibility of real-time motion tracking using cine MRI during MR-guided radiation therapy for abdominal targets
    Keiper, Timothy D.
    Tai, An
    Chen, Xinfeng
    Paulson, Eric
    Lathuiliere, Fabienne
    Beriault, Silvain
    Hebert, Francois
    Cooper, David T.
    Lachaine, Martin
    Li, X. Allen
    MEDICAL PHYSICS, 2020, 47 (08) : 3554 - 3566
  • [6] Real-Time Active MR-Tracking of Metallic Stylets in MR-Guided Radiation Therapy
    Wang, Wei
    Dumoulin, Charles L.
    Viswanathan, Akila N.
    Tse, Zion T. H.
    Mehrtash, Alireza
    Loew, Wolfgang
    Norton, Isaiah
    Tokuda, Junichi
    Seethamraju, Ravi T.
    Kapur, Tina
    Damato, Antonio L.
    Cormack, Robert A.
    Schmidt, Ehud J.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) : 1803 - 1811
  • [7] ROBUST REAL TIME MOTION ESTIMATION FOR MR-THERMOMETRY
    Roujol, S.
    Ries, M.
    Moonen, C.
    de Senneville, B. Denis
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 508 - 511
  • [8] Real-time visualization of instruments for MR-guided interventions
    Ladd, M
    Debatin, J
    6TH WORLD CONGRESS OF ENDOSCOPIC SURGERY, PTS 1 AND 2, 1998, : 681 - 686
  • [9] Real-time MR fluoroscopy for MR-guided iliac artery stent placement
    Buecker, A
    Neuerburg, JM
    Adam, GB
    Glowinski, A
    Schaeffter, T
    Rasche, V
    van Vaals, JJ
    Molgaard-Nielsen, A
    Guenther, RW
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (02) : 616 - 622
  • [10] Real-time MR fluoroscopy for MR-guided iliac artery stent placement
    Buecker, A
    Neuerburg, JM
    Adam, GB
    Glowinski, A
    Schaeffter, T
    Rasche, V
    van Vaals, JJ
    Molgaard-Nielsen, A
    Guenther, RW
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (04) : 616 - 622