Effect of False Lumen Occlusion Treatment With AFX VELA™, Candy-Plug Technique for Chronic Aortic Dissection

被引:0
|
作者
Yasuhara, Kiyomitsu [1 ]
Obayashi, Tamiyuki [1 ]
Ohki, Satoshi [1 ]
Okonogi, Shuichi [1 ]
Nagasawa, Ayako [1 ]
Yamaguchi, Ryo [1 ]
Kato, Yusuke [1 ]
Miki, Takao [1 ]
Abe, Tomonobu [2 ]
机构
[1] Isesaki City Hosp, Dept Cardiovasc Surg, 12-1 Tsunatori Hon Machi, Isesaki 3720817, Japan
[2] Gunma Univ, Dept Gen Surg Sci, Div Cardiovasc Surg, Grad Sch Med, Maebashi, Japan
关键词
chronic aortic dissection; thoracic endovascular repair; candy-plug technique; false-lumen occlusion; AFX VELA; ENDOVASCULAR REPAIR; OUTCOMES; DEVICE;
D O I
10.1177/15385744241229594
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction:<bold> </bold>We sought to examine midterm results and remodeling effect of false-lumen occlusion treatment using AFX VELA in case of chronic dissection repair. Material and methods:<bold> </bold>From June 2019 to May 2022, we performed false lumen occlusion treatment using a modified Candy-Plug technique with AFX VELA on 8 chronic aortic dissection patients with a patent false lumen. We collected operative data, short-term clinical outcomes, mid-term clinical outcomes and imaging test results. We conducted follow-up examinations at postoperative, 6-month and 1-, 2- and 3-year intervals, including contrast-enhanced computed tomography to evaluate the diameter, false lumen thrombosis and any events. Results:<bold> </bold>The average time from the symptom onset to the thoracic endovascular repair was 81.5 (35-155) months. The aorta showed aneurysmal dilation with an average maximum short-axis diameter of 58.9 (41-91) mm. Two cases needed emergency surgery due to rupture and impending rupture. There were no postoperative deaths. Complete thrombosis within the false lumen was achieved in 6 cases (75%), but 2 cases had incomplete thrombosis, requiring additional treatment. The mean maximum diameter showed a significant decrease at 6 months, 1 year and 2 years postoperatively compared to preoperative measurements (P < .05). Conclusion:<bold> </bold>We showed the results of false lumen occlusion treatment using the AFX VELA cuff. We observed favorable clinical outcomes and remodeling effects. While the long-term durability and efficacy of this technique in aortic remodeling will need to be monitored with further observation, the use of this cuff is considered a reliable approach to false lumen occlusion treatment.
引用
收藏
页码:505 / 511
页数:7
相关论文
共 50 条
  • [41] Migration of a False Lumen Occluder in a Patient with Chronic Aortic Dissection
    Yoshihiro Noda
    Noriyuki Kato
    Satofumi Tanaka
    Kensuke Oue
    Atsushi Hata
    Takashi Hashimoto
    Yoichiro Miyake
    CardioVascular and Interventional Radiology, 2017, 40 : 1807 - 1808
  • [42] Migration of a False Lumen Occluder in a Patient with Chronic Aortic Dissection
    Noda, Yoshihiro
    Kato, Noriyuki
    Tanaka, Satofumi
    Oue, Kensuke
    Hata, Atsushi
    Hashimoto, Takashi
    Miyake, Yoichiro
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 40 (11) : 1807 - 1808
  • [43] Effect of Endovascular Treatment on the Pressure in the False Lumen of Type B Aortic Dissection
    Gokalp, Orhan
    Yesilkaya, Nihan Karakas
    Iner, Hasan
    Besir, Yuksel
    Gokalp, Gamze
    Yilik, Levent
    Gurbuz, Ali
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 58 (04) : 629 - 629
  • [44] Aortic remodeling after false lumen occlusion using an atrial septal occluder in chronic DeBakey IIIb aortic dissection
    Lu, Heng
    Lin, Zhiqin
    Chen, Yi
    Lin, Feng
    Dai, Xiaofu
    Chen, Liangwan
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (06) : 1864 - +
  • [45] The Knickerbocker Technique: Technical Aspects and Single-Center Results of a New Endovascular Method for False Lumen Occlusion in Chronic Aortic Dissection
    Rohlffs, Fiona
    Tsilimparis, Nikolaos
    Panuccio, Giuseppe
    Heidemann, Franziska
    Behrendt, Christian-Alexander
    Koelbel, Tilo
    JOURNAL OF ENDOVASCULAR THERAPY, 2023, 30 (04) : 609 - 614
  • [46] Aortic Arch False Lumen Embolisation in a Residual Chronic Type A Aortic Dissection
    Pellenc, Quentin
    Castier, Yves
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 58 (04) : 600 - 601
  • [47] Outcomes of stented graft treatment of the false lumen in aortic dissection
    Kato, M
    Matsuda, T
    Kaneko, M
    Kuratani, T
    Mizushima, T
    Seo, Y
    Ohnishi, K
    CIRCULATION, 1997, 96 (08) : 1028 - 1028
  • [48] Aortic Diameter, True Lumen, and False Lumen Growth Rates in Chronic Type B Aortic Dissection
    Blount, Kevin J.
    Hagspiel, Klaus D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05) : W222 - W229
  • [49] Chronic thoracoabdominal aortic dissection: endovascular options to obliterate the false lumen
    Vargo, Patrick R.
    Maigrot, Jean-Luc
    Roselli, Eric E.
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (06) : 778 - 783
  • [50] Occlusion of the true lumen at the ascending aorta with chronic type A aortic dissection
    Uchida, Naomichi
    Katayama, Akira
    Sutoh, Miwa
    Sueda, Taijiro
    JOURNAL OF VASCULAR SURGERY, 2012, 56 (06) : 1738 - 1738