Effect of False Lumen Occlusion Treatment With AFX VELA™, Candy-Plug Technique for Chronic Aortic Dissection

被引:0
|
作者
Yasuhara, Kiyomitsu [1 ]
Obayashi, Tamiyuki [1 ]
Ohki, Satoshi [1 ]
Okonogi, Shuichi [1 ]
Nagasawa, Ayako [1 ]
Yamaguchi, Ryo [1 ]
Kato, Yusuke [1 ]
Miki, Takao [1 ]
Abe, Tomonobu [2 ]
机构
[1] Isesaki City Hosp, Dept Cardiovasc Surg, 12-1 Tsunatori Hon Machi, Isesaki 3720817, Japan
[2] Gunma Univ, Dept Gen Surg Sci, Div Cardiovasc Surg, Grad Sch Med, Maebashi, Japan
关键词
chronic aortic dissection; thoracic endovascular repair; candy-plug technique; false-lumen occlusion; AFX VELA; ENDOVASCULAR REPAIR; OUTCOMES; DEVICE;
D O I
10.1177/15385744241229594
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction:<bold> </bold>We sought to examine midterm results and remodeling effect of false-lumen occlusion treatment using AFX VELA in case of chronic dissection repair. Material and methods:<bold> </bold>From June 2019 to May 2022, we performed false lumen occlusion treatment using a modified Candy-Plug technique with AFX VELA on 8 chronic aortic dissection patients with a patent false lumen. We collected operative data, short-term clinical outcomes, mid-term clinical outcomes and imaging test results. We conducted follow-up examinations at postoperative, 6-month and 1-, 2- and 3-year intervals, including contrast-enhanced computed tomography to evaluate the diameter, false lumen thrombosis and any events. Results:<bold> </bold>The average time from the symptom onset to the thoracic endovascular repair was 81.5 (35-155) months. The aorta showed aneurysmal dilation with an average maximum short-axis diameter of 58.9 (41-91) mm. Two cases needed emergency surgery due to rupture and impending rupture. There were no postoperative deaths. Complete thrombosis within the false lumen was achieved in 6 cases (75%), but 2 cases had incomplete thrombosis, requiring additional treatment. The mean maximum diameter showed a significant decrease at 6 months, 1 year and 2 years postoperatively compared to preoperative measurements (P < .05). Conclusion:<bold> </bold>We showed the results of false lumen occlusion treatment using the AFX VELA cuff. We observed favorable clinical outcomes and remodeling effects. While the long-term durability and efficacy of this technique in aortic remodeling will need to be monitored with further observation, the use of this cuff is considered a reliable approach to false lumen occlusion treatment.
引用
收藏
页码:505 / 511
页数:7
相关论文
共 50 条
  • [1] False Lumen Occlusion in Chronic Aortic Dissection: The New Generation Candy-Plug II
    Rohlffs, Fiona
    Tsilimparis, Nikolaos
    Mogensen, John
    Makaloski, Vladimir
    Debus, Sebastian
    Koelbel, Tilo
    ANNALS OF VASCULAR SURGERY, 2019, 57 : 261 - 265
  • [2] A modified candy-plug technique to occlude false lumen in aortic dissection
    Palm, Erik
    Valtola, Antti
    Manninen, Hannu
    Saari, Petri
    CVIR ENDOVASCULAR, 2022, 5 (01)
  • [3] A modified candy-plug technique to occlude false lumen in aortic dissection
    Erik Palm
    Antti Valtola
    Hannu Manninen
    Petri Saari
    CVIR Endovascular, 5
  • [4] Candy-Plug Technique Using an Excluder Aortic Extender for Distal Occlusion of a Large False Lumen Aneurysm in Chronic Aortic Dissection
    Ogawa, Yukihisa
    Nishimaki, Hiroshi
    Chiba, Kiyoshi
    Murakami, Kenji
    Sakurai, Yuka
    Fujiwara, Keishi
    Miyairi, Takeshi
    Nakajima, Yasuo
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (03) : 483 - 486
  • [5] Candy-Plug Generation II for False Lumen Occlusion in Chronic Aortic Dissection: Feasibility and Early Results
    Eleshra, Ahmed
    Koelbel, Tilo
    Tsilimparis, Nikolaos
    Panuccio, Giuseppe
    Scheerbaum, Martin
    Debus, E. Sebastian
    Mogensen, John
    Rohlffs, Fiona
    JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (06) : 782 - 786
  • [6] Modified candy-plug device for aneurysmal false lumen occlusion in chronic type B aortic dissection
    Wu, I-Hui
    Chan, Chih-Yang
    Luo, Chien-Ming
    Wang, Shoei-Shen
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (05): : 1970 - +
  • [7] Distal False Lumen Occlusion in Aortic Dissection With a Homemade Extra-Large Vascular Plug: The Candy-Plug Technique
    Koelbel, Tilo
    Lohrenz, Christina
    Kieback, Arne
    Diener, Holger
    Debus, Eike Sebastian
    Larena-Avellaneda, Axel
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (04) : 484 - 489
  • [8] The Candy-Plug Technique: Technical Aspects and Early Results of a New Endovascular Method for False Lumen Occlusion in Chronic Aortic Dissection
    Rohlffs, Fiona
    Tsilimparis, Nikolaos
    Fiorucci, Beatrice
    Heidemann, Franziska
    Debus, Eike Sebastian
    Koelbel, Tilo
    JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (04) : 549 - 555
  • [9] Aortic Remodeling After Custom-Made Candy-Plug for Distal False Lumen Occlusion in Aortic Dissection
    Eleshra, Ahmed
    Rohlffs, Fiona
    Spanos, Konstantinos
    Panuccio, Giuseppe
    Heidemann, Franziska
    Tsilimparis, Nikolaos
    Kolbel, Tilo
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (03) : 399 - 406
  • [10] Modified Candy-Plug Technique for Rescue Type B Aortic Dissection with False Lumen Rupture
    Lin, Chun-Yu
    Su, I-Hao
    Chu, Sung-Yu
    Ko, Po-Jen
    ANNALS OF VASCULAR SURGERY, 2019, 56 : 355.e7 - 355.e9