Radiation dose to multidisciplinary staff members during complex interventional procedures

被引:1
|
作者
Mussmann, B. [1 ,2 ,3 ,5 ]
Larsen, T. R. [2 ]
Godballe, M. [2 ]
Abdi, A. J. [1 ,4 ]
Kantso, A. [2 ]
Jakobsen, A. R. [2 ]
Nielsen, M. V. [2 ]
Jensen, J. [1 ,2 ]
机构
[1] Univ Southern Denmark, Res & Innovat Unit Radiol, Kloevervaenget 10,2 Floor, DK-5000 Odense C, Denmark
[2] Odense Univ Hosp, Dept Radiol, JB Winslows Vej 4, DK-5000 Odense C, Denmark
[3] Oslo Metropolitan Univ, Fac Hlth Sci, Pilestedet 48, Oslo, Norway
[4] Reg Southern Denmark, Dept Clin Engn, Kloevervaenget 18, DK-5000 Odense C, Denmark
[5] Odense Univ Hosp, Dept Radiol, Klovervaenget 10,2nd floor, DK-5000 Odense C, Denmark
关键词
Radiation protection; Interventional radiology; Endovascular aortic repair; Transjugular intrahepatic portosystemic shunt; Prostate artery embolization; Uterine fibroid embolization; DOSIMETRY SYSTEM; TIME; EXPOSURE; PATIENT; RADIOLOGIST; PROTECTION; REDUCTION;
D O I
10.1016/j.radi.2024.01.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Complex interventional radiology procedures involve extensive fluoroscopy and image acquisition while staff are in-room. Monitoring occupational radiation dose is crucial in optimization. The purpose was to determine radiation doses received by staff involved in complex interventional procedures performed in a dedicated vascular or neuro intervention room. Methods: Individual real-time radiation dose for all staff involved in vascular and neuro-interventional procedures in adult patients was recorded over a one-year period using wireless electronic dosimeters attached to the apron thyroid shield. A reference dosimeter was attached to the C-arm near the tube housing to measure scattered, unshielded radiation. Radiology staff carried shoulder thermoluminescent dosimeters with monthly read-out to monitor dose over time. Results: Occupational radiation dose was measured in 99 interventional procedures. In many cases prostate artery embolization procedures exposed radiologists to high radiation doses with a median of 15.0 mu Sv and a very large spread, i.e. 0.2-152.5 mu Sv. In all procedures except uterine fibroid embolization radiographers were exposed to lower doses than those of radiologists, with endovascular aortic repair being the procedure with highest median exposure to assisting radiographers, i.e. 2.2 mu Sv ranging from 0.1 to 36.1 mu Sv. Median radiation dose for the reference dosimeter was 670 mu Gy while median staff dose for all procedures combined was 3.2 mu Gy. Conclusion: Radiation doses for multiple staff were determined and the ratio between staff dose and reference dosimeter indicated proper use of shielding in general. Some high-dose procedures may need further optimization for certain staff members, especially those not primarily employed in radiology. Implications for practice: The study provides benchmark doses that may be used widely in audits and in the ongoing effort to optimize radiation protection for staff in interventional radiology. (c) 2024 The Author(s). Published by Elsevier Ltd on behalf of The College of Radiographers.
引用
收藏
页码:512 / 516
页数:5
相关论文
共 50 条
  • [31] Radiation Dose Measurements and Monitoring for Fluoroscopically Guided Interventional Procedures
    Baiter, Stephen
    Miller, Donald L.
    Schueler, Beth A.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2012, 9 (08) : 595 - 597
  • [32] EVALUATING THE MAXIMUM PATIENT RADIATION DOSE IN CARDIAC INTERVENTIONAL PROCEDURES
    Kato, Mamoru
    Chida, Koichi
    Sato, Tadaya
    Oosaka, Hajime
    Tosa, Tetsuo
    Kadowaki, Ken
    RADIATION PROTECTION DOSIMETRY, 2011, 143 (01) : 69 - 73
  • [33] Patient radiation dose audits for fluoroscopically guided interventional procedures
    Balter, Stephen
    Rosenstein, Marvin
    Miller, Donald L.
    Schueler, Beth
    Spelic, David
    MEDICAL PHYSICS, 2011, 38 (03) : 1611 - 1618
  • [34] Clinical Determinants of Radiation Dose in Percutaneous Coronary Interventional Procedures
    Fetterly, Kenneth A.
    Lennon, Ryan J.
    Bell, Malcolm R.
    Holmes, David R., Jr.
    Rihal, Charanjit S.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) : 336 - 343
  • [35] Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff
    Jarvinen, H.
    Buls, N.
    Clerinx, P.
    Jansen, J.
    Miljanic, S.
    Nikodemova, D.
    Ranogajec-Komor, M.
    d'Errico, F.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 333 - 339
  • [36] Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures
    Fletcher, DW
    Miller, DL
    Balter, S
    Taylor, MA
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (04) : 391 - 397
  • [37] Evaluation of Patient Radiation Dose during Cardiac Interventional Procedures: What Is the Most Effective Method?
    Chida, K.
    Kagaya, Y.
    Saito, H.
    Ishibashi, T.
    Takahashi, S.
    Zuguchi, M.
    ACTA RADIOLOGICA, 2009, 50 (05) : 474 - 481
  • [38] Radiation Dose Associated with Dialysis Vascular Access Interventional Procedures in the Interventional Nephrology Facility
    Beathard, Gerald A.
    Urbanes, Aris
    Litchfield, Terry
    SEMINARS IN DIALYSIS, 2013, 26 (04) : 503 - 510
  • [39] Management of Patient and Staff Radiation Dose in Interventional Radiology: Current Concepts
    Bartal, Gabriel
    Vano, Eliseo
    Paulo, Graciano
    Miller, Donald L.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (02) : 289 - 298
  • [40] Management of Patient and Staff Radiation Dose in Interventional Radiology: Current Concepts
    Gabriel Bartal
    Eliseo Vano
    Graciano Paulo
    Donald L. Miller
    CardioVascular and Interventional Radiology, 2014, 37 : 289 - 298