Radiation dose to multidisciplinary staff members during complex interventional procedures

被引:1
|
作者
Mussmann, B. [1 ,2 ,3 ,5 ]
Larsen, T. R. [2 ]
Godballe, M. [2 ]
Abdi, A. J. [1 ,4 ]
Kantso, A. [2 ]
Jakobsen, A. R. [2 ]
Nielsen, M. V. [2 ]
Jensen, J. [1 ,2 ]
机构
[1] Univ Southern Denmark, Res & Innovat Unit Radiol, Kloevervaenget 10,2 Floor, DK-5000 Odense C, Denmark
[2] Odense Univ Hosp, Dept Radiol, JB Winslows Vej 4, DK-5000 Odense C, Denmark
[3] Oslo Metropolitan Univ, Fac Hlth Sci, Pilestedet 48, Oslo, Norway
[4] Reg Southern Denmark, Dept Clin Engn, Kloevervaenget 18, DK-5000 Odense C, Denmark
[5] Odense Univ Hosp, Dept Radiol, Klovervaenget 10,2nd floor, DK-5000 Odense C, Denmark
关键词
Radiation protection; Interventional radiology; Endovascular aortic repair; Transjugular intrahepatic portosystemic shunt; Prostate artery embolization; Uterine fibroid embolization; DOSIMETRY SYSTEM; TIME; EXPOSURE; PATIENT; RADIOLOGIST; PROTECTION; REDUCTION;
D O I
10.1016/j.radi.2024.01.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Complex interventional radiology procedures involve extensive fluoroscopy and image acquisition while staff are in-room. Monitoring occupational radiation dose is crucial in optimization. The purpose was to determine radiation doses received by staff involved in complex interventional procedures performed in a dedicated vascular or neuro intervention room. Methods: Individual real-time radiation dose for all staff involved in vascular and neuro-interventional procedures in adult patients was recorded over a one-year period using wireless electronic dosimeters attached to the apron thyroid shield. A reference dosimeter was attached to the C-arm near the tube housing to measure scattered, unshielded radiation. Radiology staff carried shoulder thermoluminescent dosimeters with monthly read-out to monitor dose over time. Results: Occupational radiation dose was measured in 99 interventional procedures. In many cases prostate artery embolization procedures exposed radiologists to high radiation doses with a median of 15.0 mu Sv and a very large spread, i.e. 0.2-152.5 mu Sv. In all procedures except uterine fibroid embolization radiographers were exposed to lower doses than those of radiologists, with endovascular aortic repair being the procedure with highest median exposure to assisting radiographers, i.e. 2.2 mu Sv ranging from 0.1 to 36.1 mu Sv. Median radiation dose for the reference dosimeter was 670 mu Gy while median staff dose for all procedures combined was 3.2 mu Gy. Conclusion: Radiation doses for multiple staff were determined and the ratio between staff dose and reference dosimeter indicated proper use of shielding in general. Some high-dose procedures may need further optimization for certain staff members, especially those not primarily employed in radiology. Implications for practice: The study provides benchmark doses that may be used widely in audits and in the ongoing effort to optimize radiation protection for staff in interventional radiology. (c) 2024 The Author(s). Published by Elsevier Ltd on behalf of The College of Radiographers.
引用
收藏
页码:512 / 516
页数:5
相关论文
共 50 条
  • [21] Radiation-Induced Noncancer Risks in Interventional Cardiology: Optimisation of Procedures and Staff and Patient Dose Reduction
    Sun, Zhonghua
    AbAziz, Aini
    Yusof, Ahmad Khairuddin Md
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [22] RADIATION DOSE TO PATIENTS IN CORONARY INTERVENTIONAL PROCEDURES: A SURVEY
    Brindhaban, A.
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (01) : 1 - 4
  • [23] Patient radiation dose during diagnostic and interventional cardiology procedures A study in a tertiary hospital
    Anim-Sampong, Samuel
    Antwi, William Kwadwo
    Adomako, John Bright
    Botwe, Benard Ohene
    Sarkodie, Benjamin Dabo
    Brakohiapa, Edmund K.
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2023, 54 (02) : 298 - 305
  • [24] Occupational radiation dose during fluoroscopy guided interventional procedures at Institut Kanser Negara
    Boharil, A.
    Hashim, S.
    Mustafa, S. N. M.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [25] Evaluation of patients' and occupational radiation risk dose during conventional and interventional radiology procedures
    Tamam, Nissren
    Salah, H.
    Almogren, Kholoud S.
    Mahgoub, Omer
    Saeed, Mohammed Khalil
    Abdullah, Yousef
    Tai, Duong Thanh
    Omer, Hiba
    Sulieman, Abdelmoneim
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 207
  • [26] Staff radiation dose and estimated risk in an interventional radiology department
    Alkhorayef, M.
    Al-Mohammed, H. I.
    Mayhoub, Fareed H.
    Sulieman, Abdelmoneim
    Salah, Hassan
    Yousef, M.
    Alomair, Othman I.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 178
  • [27] SCATTER DOSE VALUES IN LOWER EXTREMITIES FOR STAFF DURING PAEDIATRIC INTERVENTIONAL CARDIOLOGY PROCEDURES: AN EXPERIMENTAL APPROACH
    Ubeda, Carlos
    Miranda, Patricia
    Aguirre, Daniel
    Riquelme, Nemorino
    Dalmazzo, Dandaro
    Vega, Juan
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (01) : 88 - 93
  • [28] Radiation dosage during interventional neuroradiological procedures
    O'Dea, TJ
    Latchaw, RE
    Geise, RA
    RADIATION PROTECTION IN MEDICINE: CONTEMPORARY ISSUES, 1999, (21): : 297 - 338
  • [29] Occupational radiation doses during interventional procedures
    Nuraeni, N.
    Hiswara, E.
    Kartikasari, D.
    Waris, A.
    Haryanto, F.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [30] Staff radiation dose during percutaneous coronary procedures: Role of adjunctive protective drapes
    Sciahbasi, Alessandro
    Sarandrea, Alessandro
    Rigattieri, Stefano
    Patrizi, Roberto
    Cera, Maria
    Di Russo, Cristian
    Perone, Francesco
    Porretta, Vanessa
    Fedele, Silvio
    Romano, Silvio
    Penco, Maria
    Ferraiuolo, Giuseppe
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2018, 19 (07) : 755 - 758