Neutron collimator design of neutron radiography based on the BNCT facility

被引:0
|
作者
杨晓鹏 [1 ]
俞伯祥 [2 ]
李义国 [3 ]
彭旦 [3 ]
鲁谨 [3 ]
张高龙 [1 ]
赵航 [2 ]
章爱武 [2 ]
李春阳 [4 ]
刘万金 [2 ]
胡涛 [2 ]
吕军光 [2 ]
机构
[1] School of Physics and Nuclear Energy Engineering, Beihang University
[2] State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, Chinese Academy of Sciences
[3] China Institute of Atomic Energy
[4] University of South China
基金
中国国家自然科学基金;
关键词
neutron radiography; ICCD camera; thermal neutron collimator; thermal neuron flux; collimation ratio(L/D;
D O I
暂无
中图分类号
O571.56 [中子衍射及其应用];
学科分类号
0827 ; 082701 ;
摘要
For the research of CCD neutron radiography,a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy(BNCT)reactor.Based on the Geant4 simulations,the preliminary choice of the size of the collimator was determined.The materials were selected according to the literature data.Then,a collimator was constructed and tested on site.The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0×106n/cm2/s,the maximum collimation ratio(L/D)is 58,the Cd-ratio(Mn)is 160 and the diameter of collimator end is 10 cm.This neutron collimator is considered to be applicable for neutron radiography.
引用
收藏
页码:103 / 106
页数:4
相关论文
共 50 条
  • [21] Shielding design of a treatment room for an accelerator-based epithermal neutron irradiation facility for BNCT
    Evans, JF
    Blue, TE
    HEALTH PHYSICS, 1996, 71 (05): : 692 - 699
  • [22] Design and Optimization of Shielding Collimator System for 14 MeV Fast Neutron Radiography
    Wang J.
    Li Y.
    Li T.
    Wang Y.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (06): : 1105 - 1111
  • [23] A neutron capture radiography facility at PSI
    Teichmann, S
    Crawford, JF
    Larsson, B
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A128 - A132
  • [24] Optimization study of some neutron imaging parameters in a reactor based neutron radiography facility
    Rezazadeh, M.
    Jafari, H.
    Feghhi, S. A. H.
    Omidi, Z.
    Gholamzadeh, Z.
    PROGRESS IN NUCLEAR ENERGY, 2016, 87 : 20 - 25
  • [25] Thermal neutron beam modification studies using an isotope based neutron radiography facility
    Baheti, GL
    Khatri, PK
    Meghwal, LR
    Meena, VL
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 1457 - 1460
  • [26] On line neutron beam monitoring of the Finnish BNCT facility
    Tanner, V
    Auterinen, I
    Helin, J
    Kosunen, A
    Savolainen, S
    15TH EUROPEAN TRIGA CONFERENCE, 1999, 197 : 181 - 189
  • [27] Scintillation Detector for Neutron Flux Monitoring at the BNCT Facility
    Leonov, V. V.
    Porosev, V. V.
    Savinov, G. A.
    Taskaev, S. Yu.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2024, 67 (SUPPL2) : S311 - S315
  • [28] Spectral tailoring study on neutron irradiation facility for BNCT
    Aizawa, O
    NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE, 1997, 2867 : 60 - 63
  • [29] SHIELDING DESIGN ON NEUTRON RADIOGRAPHY FACILITY FOR KOEBERG FUEL-RODS
    VANROOYEN, TJ
    HEALTH PHYSICS, 1986, 50 (02): : 314 - 314
  • [30] A Monte Carlo evaluation of neutron images quality in a research reactor based neutron radiography facility
    Jafari, H.
    Dastjerdi, M. H. Choopan
    Moghadam, S. Rajabi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 976