摘要
For the research of CCD neutron radiography,a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy(BNCT)reactor.Based on the Geant4 simulations,the preliminary choice of the size of the collimator was determined.The materials were selected according to the literature data.Then,a collimator was constructed and tested on site.The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0×106n/cm2/s,the maximum collimation ratio(L/D)is 58,the Cd-ratio(Mn)is 160 and the diameter of collimator end is 10 cm.This neutron collimator is considered to be applicable for neutron radiography.
引用
收藏
页码:103 / 106
页数:4
相关论文
共 50 条
  • [11] Design of a neutron radiography facility at the spallation source SINQ
    Lehmann, E
    Pleinert, H
    Wiezel, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (01): : 11 - 15
  • [12] Design study on an accelerator-based facility for BNCT and low energy neutron source
    Yokobori, H
    Sasaki, M
    Yamanaka, T
    PROGRESS IN NUCLEAR ENERGY, 2000, 37 (1-4) : 321 - 326
  • [13] Design of an epithermal column for BNCT based on D-D fusion neutron facility
    Durisi, E.
    Zanini, A.
    Manfredotti, C.
    Palamara, F.
    Sarotto, M.
    Visca, L.
    Nastasi, U.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (02): : 363 - 369
  • [14] MITR NEUTRON RADIOGRAPHY FACILITY
    WESTBERG, EL
    GWINN, DA
    COLLINS, KD
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1971, 14 (02): : 534 - &
  • [15] CFRMF NEUTRON RADIOGRAPHY FACILITY
    STEPAN, IE
    ANDERSON, DM
    HARKER, YD
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1978, 30 (NOV): : 144 - 145
  • [16] Optimization study for BNCT facility based on a DT neutron generator
    Fantidis, J. G.
    Antoniadis, A.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2015, 13 (01): : 13 - 24
  • [17] NEUTRON RADIOGRAPHY SYSTEM COLLIMATOR DESIGN VIA MONTE CARLO CALCULATION
    Jafari, Hamid
    Shahriari, Majid
    PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING 2010, VOL 3, 2011, : 187 - +
  • [18] Collimator design for neutron radiography station using Monte Carlo simulation
    Wonglee, S.
    Liamsuwan, T.
    Pornroongruengchok, W.
    Channuie, J.
    Picha, R.
    Khaweerat, S.
    SIAM PHYSICS CONGRESS 2018 (SPC2018): A CREATIVE PATH TO SUSTAINABLE INNOVATION, 2018, 1144
  • [19] Thermal Neutron Filter Design for the Neutron Radiography Facility at the LVR-15 Reactor
    Soltes, Jaroslav
    Viererbl, Ladislav
    Lahodova, Zdena
    Koleska, Michal
    Vins, Miroslav
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (03) : 1640 - 1644
  • [20] Study on collimator design for Neutron Science Facility of RAON accelerator complex
    Lee, Eunjoong
    Lee, Cheol-Woo
    Yang, Sung-Chul
    Lee, Young-Ouk
    Cho, Gyuseong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 902 : 138 - 143