Neutron collimator design of neutron radiography based on the BNCT facility

被引:0
|
作者
杨晓鹏 [1 ]
俞伯祥 [2 ]
李义国 [3 ]
彭旦 [3 ]
鲁谨 [3 ]
张高龙 [1 ]
赵航 [2 ]
章爱武 [2 ]
李春阳 [4 ]
刘万金 [2 ]
胡涛 [2 ]
吕军光 [2 ]
机构
[1] School of Physics and Nuclear Energy Engineering, Beihang University
[2] State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, Chinese Academy of Sciences
[3] China Institute of Atomic Energy
[4] University of South China
基金
中国国家自然科学基金;
关键词
neutron radiography; ICCD camera; thermal neutron collimator; thermal neuron flux; collimation ratio(L/D;
D O I
暂无
中图分类号
O571.56 [中子衍射及其应用];
学科分类号
0827 ; 082701 ;
摘要
For the research of CCD neutron radiography,a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy(BNCT)reactor.Based on the Geant4 simulations,the preliminary choice of the size of the collimator was determined.The materials were selected according to the literature data.Then,a collimator was constructed and tested on site.The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0×106n/cm2/s,the maximum collimation ratio(L/D)is 58,the Cd-ratio(Mn)is 160 and the diameter of collimator end is 10 cm.This neutron collimator is considered to be applicable for neutron radiography.
引用
收藏
页码:103 / 106
页数:4
相关论文
共 50 条
  • [1] Neutron collimator design of neutron radiography based on the BNCT facility
    Yang Xiao-Peng
    Yu Bo-Xiang
    Li Yi-Guo
    Peng Dan
    Lu Jin
    Zhang Gao-Long
    Zhao Hang
    Zhang Ai-Wu
    Li Chun-Yang
    Liu Wan-Jin
    Hu Tao
    Lu Jun-Guang
    CHINESE PHYSICS C, 2014, 38 (02)
  • [2] Neutron collimator design of neutron radiography based on the BNCT facility
    杨晓鹏
    俞伯祥
    李义国
    彭旦
    鲁谨
    张高龙
    赵航
    章爱武
    李春阳
    刘万金
    胡涛
    吕军光
    Chinese Physics C, 2014, 38 (02) : 103 - 106
  • [3] Simulation design of the collimator for thermal neutron radiography facility based on neutron tube
    Li, Huanyu
    Zhao, Chenyi
    Qiao, Shuang
    Zhang, Tian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 985 (985):
  • [4] Design of moderator and collimator for compact neutron radiography systems
    Li, Huanyu
    Zhao, Chenyi
    Qiao, Shuang
    Zhang, Tian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 959 (959):
  • [5] Monte Carlo simulation for designing collimator of the neutron radiography facility in Malaysia
    Jamro, Rafhayudi
    Kardjilov, Nikolay
    HairieRabir, Mohamad
    Zain, Mohamed Rawi Mohd
    Mohamed, Abdul Aziz
    Ali, NurSazwani Mohd
    Idris, Faridah
    Ahmad, Megat Harun Al Rashid Megat
    Yazid, Khairiah
    Yazid, Hafizal
    Azman, Azraf
    Mamat, Mohd Rizal
    NEUTRON IMAGING FOR APPLICATIONS IN INDUSTRY AND SCIENCE, 2017, 88 : 361 - 368
  • [6] DIVERGENT BEAM COLLIMATOR FOR NEUTRON RADIOGRAPHY
    BARTON, JP
    MATERIALS EVALUATION, 1967, 25 (09) : A45 - &
  • [7] SIMPLE AND INEXPENSIVE COLLIMATOR FOR NEUTRON RADIOGRAPHY
    OLSEN, J
    MORTENSEN, L
    NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (03): : 617 - 618
  • [8] BNCT EPITHERMAL NEUTRON BEAM MAPPING BY USING INDIRECT NEUTRON RADIOGRAPHY
    Liu, Yuan-Hao
    Huang, Chun-Kai
    Tsai, Pi-En
    Chen, Ang-Yu
    Liu, Hong-Ming
    Lee, Shih-Chung
    Jiang, Shiang-Huei
    NUCLEAR TECHNOLOGY, 2009, 168 (02) : 354 - 358
  • [9] Characterization of a BNCT beam using neutron activation and indirect neutron radiography
    Tsai, Pi-En
    Liu, Yuan-Hao
    Liu, Hong-Ming
    Jiang, Shiang-Huei
    RADIATION MEASUREMENTS, 2010, 45 (10) : 1167 - 1170
  • [10] Conceptual design of the cold neutron radiography facility at HANARO
    Lee, Seung Wook
    Kardjilov, Nikolay
    Cho, Sang Jin
    Sim, Cheul Muu
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 643 - 647