Effects of supply air temperature and inlet location on particle dispersion in displacement ventilation rooms

被引:0
|
作者
Yanming Kang
机构
基金
中国国家自然科学基金;
关键词
Displacement ventilation; Particle dispersion; Numerical simulation; Supply air temperature; Inlet location;
D O I
暂无
中图分类号
X513 [粒状污染物];
学科分类号
摘要
The effects of supply temperature and vertical location of inlet air on particle dispersion in a displacement ventilated (DV) room were numerically modeled with validation by experimental data from the literature. The results indicate that the temperature and vertical location of inlet supply air did not greatly affect the air distribution in the upper parts of a DV room, but could signiflcantly influence the airflow pattern in the lower parts of the room, thus affecting the indoor air quality with contaminant sources located at the lower level, such as particles from working activities in an offlce. The numerical results also show that the inlet location would slightly influence the relative ventilation efflciency for the same air supply volume, but particle concentration in the breathing zone would be slightly lower with a low horizontal wall slot than a rectangular diffuser. Comparison of the results for two different supply temperatures in a DV room shows that, although lower supply temperature means less incoming air volume, since the indoor flow is mainly driven by buoyancy, lower supply temperature air could more efflciently remove passive sources (such as particles released from work activities in an offlce). However, in the breathing zone it gives higher concentration as compared to higher supply air temperature. To obtain good indoor air quality, low supply air temperature should be avoided because concentration in the breathing zone has a stronger and more direct impact on human health.
引用
收藏
页码:619 / 625
页数:7
相关论文
共 50 条
  • [31] MODELING PARTICLE-TRANSPORT AND AIR-FLOW IN CEILING INLET VENTILATION SYSTEMS
    WORLEY, MS
    MANBECK, HB
    TRANSACTIONS OF THE ASAE, 1995, 38 (01): : 231 - 239
  • [32] Indoor thermal environment in rooms with combined air conditioning system of displacement ventilation and chilled ceiling panel
    School of Muni. and Eviron. Eng., Xi'an Univ. of Arch. and Tech, Xi'an 710055, China
    Xi'an Jianzhu Keji Daxue Xuebao, 2007, 4 (558-562):
  • [33] CFD simulation of influence of air supply location on airflow and temperature in stacked-cage hen house with tunnel ventilation
    Cheng Q.
    Mu Y.
    Li B.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2019, 35 (15): : 192 - 199
  • [34] Effects of source type and location on contaminant dispersion in a displacement ventilated room
    He, GQ
    Yang, XD
    Srebric, J
    ASHRAE Transactions 2005, Vol 111, Pt 1, 2005, 111 : 646 - 652
  • [35] Effect of air change rate on particle dispersion from inlet opening under varying particle source strengths
    Cetin, Yunus Emre
    Avci, Mete
    Aydin, Orhan
    INTERNATIONAL JOURNAL OF VENTILATION, 2022, 21 (03) : 177 - 194
  • [36] The impact of the air distribution method in ventilated rooms on the aerosol particle dispersion and removal: The experimental approach
    Jurelionis, Andrius
    Gagyte, Laura
    Prasauskas, Tadas
    Ciuzas, Darius
    Krugly, Edvinas
    Seduikyte, Lina
    Martuzevicius, Dainius
    ENERGY AND BUILDINGS, 2015, 86 : 305 - 313
  • [37] Study on indoor thermal environment and air quality of office rooms controlled by personal displacement ventilation using CFD
    Zhao, JN
    Wang, LN
    Liu, J
    Gao, J
    Luo, ZW
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 664 - 668
  • [38] Effect of Supply Air Temperature on Air Distribution in a Room with Radiant Heating and Mechanical Ventilation
    Wu, Xiaozhou
    Fang, Lei
    Olesen, Bjarne W.
    Zhao, Jianing
    Wang, Fenghao
    ASHRAE TRANSACTIONS 2017, VOL 123, PT 1, 2017, 123 : 120 - 128
  • [39] EVALUATING THE EFFECTS OF A CLEANROOM AIR SHOWER ON PARTICLE DISPERSION
    WHYTE, W
    MCGEORGE, D
    MICROCONTAMINATION, 1994, 12 (09): : 39 - &
  • [40] Comparison of Airflow and Contaminant Distributions in Rooms with Traditional Displacement Ventilation and Under-Floor Air Distribution Systems
    Lee, Kisup
    Zhang, Tengfei
    Jiang, Zheng
    Chen, Qingyan
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 2, 2009, 115 : 306 - +