EVALUATING THE EFFECTS OF A CLEANROOM AIR SHOWER ON PARTICLE DISPERSION

被引:0
|
作者
WHYTE, W [1 ]
MCGEORGE, D [1 ]
机构
[1] GEC MARCONI AVION,EDINBURGH,SCOTLAND
来源
MICROCONTAMINATION | 1994年 / 12卷 / 09期
关键词
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Although air showers are a common feature in industrial cleanroom facilities, their contribution to a successful particle control program has been questioned. In the study reported here, tests were carried out to determine the effectiveness of an air shower within a cleanroom suite. The particle dispersal rates from volunteers who had passed through or walked around outside of an air shower were measured in a test chamber, and it was found that the use of the air shower had no significant effect. Further tests showed that airborne particle counts in the cleanroom were not significantly affected by employees' use of the air shower. Thus it was concluded that air showers have little value in reducing particle dispersion from cleanroom personnel.
引用
收藏
页码:39 / &
相关论文
共 50 条
  • [1] Particle dispersion in a cleanroom - Effects of pressurization, door opening and traffic flow
    Bhattacharya, Arup
    Metcalf, Andrew R.
    Nafchi, Ali Mohammadi
    Mousavi, Ehsan S.
    JOURNAL OF PLANNING LITERATURE, 2022, 37 (01) : 201 - 201
  • [2] Particle dispersion in a cleanroom - effects of pressurization, door opening and traffic flow
    Bhattacharya, Arup
    Metcalf, Andrew R.
    Nafchi, Ali Mohammadi
    Mousavi, Ehsan S.
    BUILDING RESEARCH AND INFORMATION, 2021, 49 (03): : 294 - 307
  • [3] Particle generation of ceramic emitters for cleanroom air ionizers
    Okano, K
    Posadas, A
    ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM PROCEEDINGS 1997, 1997, : 287 - 291
  • [4] Correlation between the particle dispersion and the aerodynamic characteristics in a nonunidirectional airflow cleanroom
    Tsai, CH
    Tseng, TC
    2000 PROCEEDINGS: INSTITUTE OF ENVIRONMENTAL SCIENCES AND TECHNOLOGY, 2000, : 124 - 130
  • [5] LONGITUDINAL PARTICLE DISTRIBUTION IN EXTENSIVE AIR SHOWER DISK
    WOIDNECK, CP
    BOHM, E
    JOURNAL OF PHYSICS A-MATHEMATICAL AND GENERAL, 1975, 8 (06): : 997 - 1004
  • [6] Cleanroom air quality: combined effects of ventilation rate and filtration schemes in a laboratory cleanroom
    Nikoopayan Tak, Mohammad Saleh
    Bhattacharya, Arup
    Metcalf, Andrew R.
    Mousavi, Ehsan
    BUILDING RESEARCH AND INFORMATION, 2023, 51 (06): : 717 - 729
  • [7] Clearing the cleanroom air
    Trammell, C
    IEEE SOFTWARE, 1997, 14 (04) : 10 - 10
  • [8] Non-Poissonian particle fluctuations in the cosmic ray extensive air shower and shower size estimation
    Wibig, Tadeusz
    Dam-O, Punsiri
    PHYSICS LETTERS B, 2025, 860
  • [9] Effects of different air change rates on cleanroom 'in operation' status
    Behrens, Detlef
    Schaefer, Jens
    Keck, Cornelia M.
    Runkel, Frank E.
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2021, 47 (10) : 1643 - 1655
  • [10] Evaluating the effects of flow rate reduction on the environmental parameters of an operational cleanroom
    Jue, M
    Wang, RD
    Huang, T
    Fillipovic, A
    Hundt, A
    Cooper, DW
    JOURNAL OF THE IEST, 2000, 43 (04): : 38 - 43