Scanning transmission ion microscopy on Fudan SPM facility

被引:0
|
作者
SATOH Takahiro [1 ]
机构
[1] Takasaki Advanced Radiation Research Institute,Japan Atomic Energy Agency,1233 Watanuki-machi,Takasaki,Gunma 370-1292,Japan
关键词
Energy loss; STIM; PIXE; Spatial resolution; Computed tomography;
D O I
10.13538/j.1001-8042/nst.22.282-286
中图分类号
TH742 [显微镜];
学科分类号
0803 ;
摘要
In this paper,we report a novel measurement system based on the development of Fudan Scanning Proton Microscopy(SPM) facility.By using Si-PIN diode(Hamamatsu S1223-01) detector,scanning transmission ion microscopy(STIM) measurement system has been set up.It can provide density and structural images with high probing efficiency and non-destruction by utilizing the energy loss of high energy(MeV) and focused ions penetrating through a thin sample.STIM measurement is able to map the density distribution of organic elements which mostly compose biology materials,such information can not be detected by using conventional Be-windowed Si(Li) X-ray detector in Particle Induced X-ray Emission(PIXE) technique.The spatial resolution capability of STIM is higher than PIXE technique at same accelerator status.As a result of STIM measurement,Paramecium attached on the top of Kapton tube was measured by STIM.
引用
收藏
页码:282 / 286
页数:5
相关论文
共 50 条
  • [41] Scanning transmission electron microscopy (STEM)-transmission electron microscopy (TEM) analysis of nitrogen ion implanted austenitic 302 stainless steel
    Aggarwal, S
    Goodhew, PJ
    Murray, RT
    THIN SOLID FILMS, 2004, 446 (01) : 12 - 17
  • [42] Introduction to transmission and scanning electron microscopy
    Verni, F
    Gabrielli, S
    FROM CELLS TO PROTEINS: IMAGING NATURE ACROSS DIMENSIONS, 2005, 3 : 23 - 35
  • [43] COMPRESSIVE SCANNING TRANSMISSION ELECTRON MICROSCOPY
    Nicholls, D.
    Robinson, A.
    Wells, J.
    Moshtaghpour, A.
    Bahri, M.
    Kirkland, A.
    Browning, N.
    2022 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2022, : 1586 - 1590
  • [44] TRANSMISSION AND SCANNING ELECTRON MICROSCOPY OF ENDOSPORITES
    BRACK, SD
    TAYLOR, TN
    AMERICAN JOURNAL OF BOTANY, 1970, 57 (06) : 756 - &
  • [45] ENERGY-LOSS IMAGE-FORMATION IN SCANNING-TRANSMISSION ION MICROSCOPY
    OVERLEY, JC
    SCHOFIELD, RMS
    MACDONALD, JD
    LEFEVRE, HW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1988, 30 (03): : 337 - 341
  • [46] TomoRebuild: a new data reduction software package for scanning transmission ion microscopy tomography
    Michelet-Habchi, C
    Incerti, S
    Aguer, P
    Barberet, P
    Gontier, E
    Grente, K
    Moretto, P
    Nguyen, DT
    Pouthier, A
    Pouthier, T
    Rebillat, F
    Smith, RW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 231 : 142 - 148
  • [47] Tip geometry and tip-sample interactions in scanning probe microscopy (SPM)
    Koenders, L
    Yacoot, A
    FRINGE 2005, 2006, : 456 - +
  • [48] Tunable Spatial Resolution of a Scanning Probe Microscopy (SPM) by an Efficient Cryosorption Pump
    Kumar, R. Rajesh
    Gour, Abhay Singh
    Adyam, Venimadhav
    IEEE SENSORS JOURNAL, 2023, 23 (14) : 16107 - 16114
  • [49] Evaluation of scanning Maxwell-stress microscopy for SPM-based nanoelectronics
    Dagata, JA
    NANOTECHNOLOGY, 1997, 8 : A3 - A9
  • [50] Scanning Electrochemical Microscopy versus Scanning Ion Conductance Microscopy for Surface Patterning
    Sarkar, Sujoy
    Mandler, Daniel
    CHEMELECTROCHEM, 2017, 4 (11): : 2981 - 2988