摘要
Background A novel circular pulmonary vein ablation catheter(PVAC) has been introduced for pulmonary vein isolation(PVI).Accurate delineation of left atrium-pulmonary vein(LA-PV) anatomy is important for this technique.The aim of this study was to test whether the 3-dimensional rotational angiography(3D RTA) of the left atrium can facilitate PVI using PVAC technique. Methods Twenty patients with paroxysmal atrial fibrillation(AF) were enrolled in this study.The 3D RTA was reconstructed and registered with live fluoroscopy in all the patients.AF ablation was performed with a PVAC catheter in the navigation of registered 3D RTA. Results The 3DRTA image was successfully reconstructed and registered with live fluoroscopy in all patients(100%). The LA-PV anatomy was delineated clearly in all patients.Navigation of the PVAC inside the registered 3D RTA,ensured accurate placement within the atrium to perform ablation,and the PVAC was correctly placed inside the PV ostium to verify the PVI.All the PVs were isolated.Total procedural time was(87.5±12.1) minutes,and fluoroscopy time was (20.1±6.3) minutes.Follow-up after(7.1±1.5) months showed freedom from AF in 70%(14/20) patients.No PV stenosis was observed. Conclusions Intraprocedure reconstructed and registered 3D RTA can clearly delineate the LA-PV anatomy in real-time.The results demonstrate the feasibility and reliability of combining use of 3DRA and PVAC in AF ablation procedures.
引用
收藏
页码:144 / 148
相关论文
共 50 条
  • [31] Novel Three-Dimensional Imaging of the Anatomical Relationship Between the Pulmonary Vein and Left Atrium - Transparent View
    Yamada, Minoru
    Jinzaki, Masahiro
    Sato, Kozo
    Tanami, Yutaka
    Fukumoto, Kotaro
    Tanimoto, Kojiro
    Takatsuki, Seiji
    Ogawa, Satoshi
    Kuribayashi, Sachio
    CIRCULATION JOURNAL, 2009, 73 (03) : 573 - 574
  • [32] Esophageal temperature during radiofrequency-catheter ablation of left atrium: A three-dimensional computer modeling study
    Hornero, F
    Berjano, EJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (04) : 405 - 410
  • [33] Simultaneous High-Density Contact Mapping plus Ablation of the Left Atrium for the Treatment of Atrial Fibrillation: a Novel Multi-Electrode Catheter System
    Kottkamp, Hans
    Reinders, Dan
    Moisa, Saar
    Sardari, Ashkan
    Weinkam, Daniel
    Brewster, Jeff
    Chaplin, Kevin
    CIRCULATION, 2014, 130
  • [34] Procedural efficiency is enhanced combining the pentaspline pulsed field ablation catheter with three-dimensional electroanatomical mapping system for pulmonary vein isolation
    Zamponi, Alessio Falasca
    Olson, Jens
    Scheel, Sergej
    Englund, Anders
    Scorza, Raffaele
    Tabrizi, Fariborz
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (09) : 1993 - 2001
  • [35] Registration of cardiac computed tomography images with three-dimensional electroanatomical mapping to guide catheter manipulation in the left atrium: Implications for pulmonary venous isolation
    Reddy, VY
    Malchano, Z
    Neuzil, P
    Weichet, J
    Ruskin, JN
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 115A - 116A
  • [36] Feasibility and safety of right and left ventricular three-dimensional rotational angiography for guiding catheter ablation of ventricular arrhythmias
    Starek, Zdenek
    Wolf, Jiri
    Lehar, Frantisek
    Jez, Jiri
    Kulik, Tomas
    Kulikova, Alena
    BIOMEDICAL PAPERS-OLOMOUC, 2017, 161 : S35 - S41
  • [37] Use of a multi-electrode radiofrequency balloon catheter to achieve pulmonary vein isolation in patients with paroxysmal atrial fibrillation: 12-Month outcomes of the RADIANCE study
    Dhillon, Gurpreet Singh
    Honarbakhsh, Shohreh
    Di Monaco, Antonio
    Coling, Ann Elizabeth
    Lenka, Kernerova
    Pizzamiglio, Francesca
    Hunter, Ross J.
    Horton, Rodney
    Mansour, Moussa
    Natale, Andrea
    Reddy, Vivek
    Grimaldi, Massimo
    Neuzil, Petr
    Tondo, Claudio
    Schilling, Richard J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (06) : 1259 - 1269
  • [38] Usefulness of three-dimensional pulmonary vein-left atrium image reconstructed from non-enhanced computed tomography for atrial fibrillation ablation
    Souhei Kawafuji
    Hirosuke Yamaji
    Masaaki Kayama
    Akitaka Akiyama
    Motoaki Miyahara
    Takumi Tomiya
    Takuto Koumoto
    Takuya Akagi
    Shunichi Higashiya
    Takashi Murakami
    Shozo Kusachi
    The International Journal of Cardiovascular Imaging, 2023, 39 : 2517 - 2526
  • [39] Usefulness of three-dimensional pulmonary vein-left atrium image reconstructed from non-enhanced computed tomography for atrial fibrillation ablation
    Kawafuji, Souhei
    Yamaji, Hirosuke
    Kayama, Masaaki
    Akiyama, Akitaka
    Miyahara, Motoaki
    Tomiya, Takumi
    Koumoto, Takuto
    Akagi, Takuya
    Higashiya, Shunichi
    Murakami, Takashi
    Kusachi, Shozo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (12): : 2517 - 2526
  • [40] Use of three-dimensional Intracardiac Echocardiography for assessment of pulmonary vein anatomy and lasso catheter localization
    Simon, RD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 349A - 349A