Procedural efficiency is enhanced combining the pentaspline pulsed field ablation catheter with three-dimensional electroanatomical mapping system for pulmonary vein isolation

被引:0
|
作者
Zamponi, Alessio Falasca [1 ,2 ]
Olson, Jens [1 ,2 ]
Scheel, Sergej [1 ]
Englund, Anders [1 ]
Scorza, Raffaele [2 ]
Tabrizi, Fariborz [1 ,2 ]
机构
[1] Capio Arytmicenter Stockholm AB, Stockholm, Sweden
[2] Soder Sjukhuset, Karolinska Inst, Dept Clin Sci & Educ, Div Cardiol, Stockholm, Sweden
关键词
Atrial fibrillation; Pulmonary vein isolation; Pulsed field ablation; 3D-EAM; ATRIAL-FIBRILLATION;
D O I
10.1007/s10840-024-01846-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Pulsed field ablation (PFA) offers a safe, non-thermal alternative for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Currently, the pentaspline PFA-system relies heavily on fluoroscopy for catheter manipulation, which poses challenges due to the complexity of left atrium anatomy. Incorporating three-dimensional electroanatomical mapping (3D-EAM) could improve procedural efficiency reducing dependency on fluoroscopy guidance. This study aims to evaluate the effects of integration of 3D-EAM with PFA during PVI. Methods Between September 2022 and December 2023, we retrospectively enrolled 248 patients with paroxysmal or persistent AF undergoing PVI at our center using the pentaspline PFA catheter. The control group (n = 104) received conventional PFA with fluoroscopic guidance alone, while the intervention group (n = 144) underwent PVI with PFA with 3D-EAM integration. Primary outcomes were procedural time, fluoroscopy time (FT), and dose area product (DAP). Secondary endpoints included acute procedural success and incidence of periprocedural complications. Results In the 3D-EAM-PFA group, procedural time was 63.3 +/- 14.3 min, compared to 65.6 +/- 14.9 min in the control group (p = 0.22). The 3D-EAM group experienced significantly reduced FT (9.7 +/- 4.4 min vs. 16.7 +/- 5.2 min) and DAP (119.2 +/- 121.7 cGycm(2) vs. 338.7 +/- 229.9 cGycm(2)) compared to the control group, respectively (p < 0.001). Acute procedural success was achieved in all cases. No major complications were observed in either group. Conclusion Integration of 3D-EAM with the pentaspline PFA catheter for PVI in AF treatment offers a promising approach, with significantly reduced fluoroscopy exposure without compromising procedural time and efficacy.
引用
收藏
页码:1993 / 2001
页数:9
相关论文
共 50 条
  • [1] An approach to electroanatomical mapping with a pentaspline pulsed field catheter to guide atrial fibrillation ablation
    Mills, Mark T.
    Calvert, Peter
    Phenton, Calum
    Worthington, Nicole
    Todd, Derick
    Modi, Simon
    Ashrafi, Reza
    Snowdon, Richard
    Gupta, Dhiraj
    Luther, Vishal
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2025,
  • [2] How to perform pulmonary vein isolation using a pentaspline pulsed field ablation system for treatment of atrial fibrillation
    Badertscher, Patrick
    Knecht, Sven
    Rosso, Raphael
    Krisai, Philipp
    Spreen, David
    Katic, Josip
    de Lavallaz, Jeanne Du Fay
    Sticherling, Christian
    Kuhne, Michael
    HEART RHYTHM, 2025, 22 (01) : 69 - 79
  • [3] Three-dimensional electroanatomical mapping for guidance of pulmonary vein isolation as treatment for persistent atrial fibrillation in a dog
    Helleman, A.
    Duytschaever, M.
    Van Steenkiste, G.
    van Loon, G.
    Mampaey, G.
    Bosmans, T.
    Stock, E.
    Skotarek, M.
    Smets, P.
    JOURNAL OF VETERINARY CARDIOLOGY, 2023, 49 : 1 - 8
  • [4] Experience in Application of a Three-Dimensional Pulsed Field Ablation System Integrating Mapping and Ablation
    Wang, Yan
    Qiu, Jie
    Wang, Daowen
    CARDIOVASCULAR INNOVATIONS AND APPLICATIONS, 2022, 7 (01)
  • [5] Pulmonary vein isolation after circumferential pulmonary vein ablation: Comparison between Lasso and three-dimensional electroanatomical assessment of complete electrical disconnection
    Augello, Giuseppe
    Vicedomini, Gabriele
    Saviano, Massimo
    Crisa, Simonetta
    Mazzone, Patrizio
    Ornago, Ombretta
    Zuffada, Francesca
    Santinelli, Vincenzo
    Pappone, Carlo
    HEART RHYTHM, 2009, 6 (12) : 1706 - 1713
  • [6] Catheter ablation of atrial fibrillation: three-dimensional transesophageal echocardiography for pulmonary vein imaging prior to and after pulmonary vein isolation
    Kettering, K.
    Gramley, F.
    Von Bardeleben, S.
    EUROPEAN HEART JOURNAL, 2014, 35 : 595 - 595
  • [7] Pulmonary vein isolation and left atrial catheter ablation using a three-dimensional navigation system for the treatment of atrial fibrillation
    Macle, Laurent
    Novak, Paul
    Khairy, Paul
    Thibault, Bernard
    Talajic, Mario
    Dubuc, Marc
    Roy, Denis
    Guerra, Peter G.
    CANADIAN JOURNAL OF CARDIOLOGY, 2009, 25 (06) : E169 - E172
  • [8] Catheter ablation of ventricular tachycardia following myocardial infarction using three-dimensional electroanatomical mapping
    Kautzner, J
    Cihák, R
    Peichl, P
    Vancura, V
    Bytesník, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01): : 342 - 347
  • [9] The utility of three-dimensional rotational angiography during catheter ablation for atrial fibrillation; comparison with conventional electroanatomical mapping system
    Fujita, S.
    Fujii, E.
    Sugiura, S.
    Nakamura, M.
    Ito, M.
    EUROPEAN HEART JOURNAL, 2013, 34 : 431 - 431
  • [10] Pulsed field ablation for pulmonary vein isolation: Preclinical safety and effectiveness of a novel hexaspline ablation catheter
    Yu, Fengyuan
    Dong, Xiaonan
    Ding, Lei
    Reddy, Vivek
    Tang, Min
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (11) : 2195 - 2202