A vessel bifurcation liver CT landmark pair dataset for evaluating deformable image registration algorithms

被引:0
|
作者
Zhang, Zhendong [1 ]
Criscuolo, Edward Robert [1 ]
Hao, Yao [2 ]
Mckeown, Trevor [1 ]
Yang, Deshan [1 ]
机构
[1] Duke Univ, Dept Radiat Oncol, 40 Duke Med Circle,04212,3640 DUMC, Durham, NC 27710 USA
[2] Washington Univ, Sch Med, Dept Radiat Oncol, St. Louis, MO USA
关键词
benchmark dataset; deformable image registration; image processing; RADIATION-THERAPY; ACCURACY; INFORMATION; HEAD; REGULARIZATION; RADIOTHERAPY;
D O I
10.1002/mp.17507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeEvaluating deformable image registration (DIR) algorithms is vital for enhancing algorithm performance and gaining clinical acceptance. However, there is a notable lack of dependable DIR benchmark datasets for assessing DIR performance except for lung images. To address this gap, we aim to introduce our comprehensive liver computed tomography (CT) DIR landmark dataset library. This dataset is designed for efficient and quantitative evaluation of various DIR methods for liver CTs, paving the way for more accurate and reliable image registration techniques.Acquisition and validation methodsForty CT liver image pairs were acquired from several publicly available image archives and authors' institutions under institutional review board (IRB) approval. The images were processed with a semi-automatic procedure to generate landmark pairs: (1) for each case, liver vessels were automatically segmented on one image; (2) landmarks were automatically detected at vessel bifurcations; (3) corresponding landmarks in the second image were placed using two deformable image registration methods to avoid algorithm-specific biases; (4) a comprehensive validation process based on quantitative evaluation and manual assessment was applied to reject outliers and ensure the landmarks' positional accuracy. This workflow resulted in an average of similar to 56 landmark pairs per image pair, comprising a total of 2220 landmarks for 40 cases. The general landmarking accuracy of this procedure was evaluated using digital phantoms and manual landmark placement. The landmark pair target registration errors (TRE) on digital phantoms were 0.37 +/- 0.26 and 0.55 +/- 0.34 mm respectively for the two selected DIR algorithms used in our workflow, with 97% of landmark pairs having TREs below 1.5 mm. The distances from the calculated landmarks to the averaged manual placement were 1.27 +/- 0.79 mm.Data format and usage notesAll data, including image files and landmark information, are publicly available at Zenodo (). Instructions for using our data can be found on our GitHub page at .Potential applicationsThe landmark dataset generated in this work is the first collection of large-scale liver CT DIR landmarks prepared on real patient images. This dataset can provide researchers with a dense set of ground truth benchmarks for the quantitative evaluation of DIR algorithms within the liver.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Unsupervised Deformable Ultrasound Image Registration and Its Application for Vessel Segmentation
    Abhimanyu, F. N. U.
    Orekhov, Andrew L.
    Bal, Ananya
    Galeotti, John
    Choset, Howie
    2023 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2023, : 6579 - 6585
  • [32] Assessment of Deformable Image Registration Algorithms by Using Different Similarity Measures for the Registration Evaluation
    Jurkovic, I.
    Papanikolaou, N.
    Stathakis, S.
    Mavroidis, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3286 - 3287
  • [33] Algorithm for Multiscale Residual Deformable Lung CT Image Registration
    Liu, Weipeng
    Li, Xu
    Ren, Ziwen
    Qi, Yedong
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2024, 52 (10): : 135 - 145
  • [34] Biomechanical Deformable Image Registration of Longitudinal Lung CT Images
    Cazoulat, G.
    Owen, D.
    Matuszak, M.
    Balter, J.
    Brock, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3285 - 3285
  • [35] Evaluation of Lung Hysteresis using a Bifurcation Tracking Code and Deformable Image Registration
    Moseley, J. L.
    Hunter, S. F.
    Al-Mayah, A.
    Brock, K. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S43 - S43
  • [36] Noninvasive Pulmonary Nodule Elastometry by CT and Deformable Image Registration
    Negahdar, M.
    Shultz, D. B.
    Eyben, R. V.
    Fasola, C.
    Yu, A. S.
    Tian, L.
    Fleischmann, D.
    Gable, L.
    Shan, X.
    Diehn, M.
    Loo, B. W.
    Maxim, P. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S10 - S10
  • [37] Noninvasive Pulmonary Nodule Elastometry by CT and Deformable Image Registration
    Negahdar, M.
    Shultz, D. B.
    Eyben, R. V.
    Fasola, C.
    Yu, A. S.
    Tian, L.
    Fleischmann, D.
    Gable, L.
    Shan, X.
    Diehn, M.
    Loo, B. W.
    Maxim, P. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S623 - S624
  • [38] Noninvasive pulmonary nodule elastometry by CT and deformable image registration
    Negandar, Mohammadreza
    Fasola, Carolina E.
    Yu, Amy S.
    von Eyben, Rie
    Yamamoto, Tokihiro
    Diehn, Maximilian
    Fleischmann, Dominik
    Tian, Lu
    Loo, Billy W.
    Maxim, Peter G.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 (01) : 35 - 40
  • [39] Mass Transportation for Deformable Image Registration with Application to Lung CT
    Papiez, Bartlomiej W.
    Brady, Michael
    Schnabel, Julia A.
    MOLECULAR IMAGING, RECONSTRUCTION AND ANALYSIS OF MOVING BODY ORGANS, AND STROKE IMAGING AND TREATMENT, 2017, 10555 : 66 - 74
  • [40] Landmark-Guided Deformable Image Registration for Supervised Autonomous Robotic Tumor Resection
    Ge, Jiawei
    Saeidi, Hamed
    Opfermann, Justin D.
    Joshi, Arjun S.
    Krieger, Axel
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT I, 2019, 11764 : 320 - 328