A vessel bifurcation liver CT landmark pair dataset for evaluating deformable image registration algorithms

被引:0
|
作者
Zhang, Zhendong [1 ]
Criscuolo, Edward Robert [1 ]
Hao, Yao [2 ]
Mckeown, Trevor [1 ]
Yang, Deshan [1 ]
机构
[1] Duke Univ, Dept Radiat Oncol, 40 Duke Med Circle,04212,3640 DUMC, Durham, NC 27710 USA
[2] Washington Univ, Sch Med, Dept Radiat Oncol, St. Louis, MO USA
关键词
benchmark dataset; deformable image registration; image processing; RADIATION-THERAPY; ACCURACY; INFORMATION; HEAD; REGULARIZATION; RADIOTHERAPY;
D O I
10.1002/mp.17507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeEvaluating deformable image registration (DIR) algorithms is vital for enhancing algorithm performance and gaining clinical acceptance. However, there is a notable lack of dependable DIR benchmark datasets for assessing DIR performance except for lung images. To address this gap, we aim to introduce our comprehensive liver computed tomography (CT) DIR landmark dataset library. This dataset is designed for efficient and quantitative evaluation of various DIR methods for liver CTs, paving the way for more accurate and reliable image registration techniques.Acquisition and validation methodsForty CT liver image pairs were acquired from several publicly available image archives and authors' institutions under institutional review board (IRB) approval. The images were processed with a semi-automatic procedure to generate landmark pairs: (1) for each case, liver vessels were automatically segmented on one image; (2) landmarks were automatically detected at vessel bifurcations; (3) corresponding landmarks in the second image were placed using two deformable image registration methods to avoid algorithm-specific biases; (4) a comprehensive validation process based on quantitative evaluation and manual assessment was applied to reject outliers and ensure the landmarks' positional accuracy. This workflow resulted in an average of similar to 56 landmark pairs per image pair, comprising a total of 2220 landmarks for 40 cases. The general landmarking accuracy of this procedure was evaluated using digital phantoms and manual landmark placement. The landmark pair target registration errors (TRE) on digital phantoms were 0.37 +/- 0.26 and 0.55 +/- 0.34 mm respectively for the two selected DIR algorithms used in our workflow, with 97% of landmark pairs having TREs below 1.5 mm. The distances from the calculated landmarks to the averaged manual placement were 1.27 +/- 0.79 mm.Data format and usage notesAll data, including image files and landmark information, are publicly available at Zenodo (). Instructions for using our data can be found on our GitHub page at .Potential applicationsThe landmark dataset generated in this work is the first collection of large-scale liver CT DIR landmarks prepared on real patient images. This dataset can provide researchers with a dense set of ground truth benchmarks for the quantitative evaluation of DIR algorithms within the liver.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A Method to Improve Landmark Pair Positional Accuracy for Image Registration Verification
    Yang, D.
    Fu, Y.
    Chang, X.
    Li, H.
    MEDICAL PHYSICS, 2018, 45 (06) : E152 - E152
  • [22] Automatic landmark correspondence detection in medical images with an application to deformable image registration
    Grewal, Monika
    Wiersma, Jan
    Westerveld, Henrike
    Bosman, Peter A. N.
    Alderliesten, Tanja
    JOURNAL OF MEDICAL IMAGING, 2023, 10 (01)
  • [23] Automated Estimation of Deformable Image Registration Uncertainty in the Liver
    Zhang, Y.
    Balter, J.
    Kashani, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E188 - E188
  • [24] Evaluation of various deformable image registration algorithms for thoracic images
    Kadoya, Noriyuki
    Fujita, Yukio
    Katsuta, Yoshiyuki
    Dobashi, Suguru
    Takeda, Ken
    Kishi, Kazuma
    Kubozono, Masaki
    Umezawa, Rei
    Sugawara, Toshiyuki
    Matsushita, Haruo
    Jingu, Keiichi
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (01) : 175 - 182
  • [25] A new validation method of thoracic CT to CT deformable image registration
    Nielsen, M. S.
    Ostergaard, L. R.
    Nystrom, P. M.
    Carl, J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S247 - S247
  • [26] A Comparative Evaluation of Deformable Image Registration Algorithms Based On the Jacobian
    Li, E.
    Zhong, Z.
    An, Y.
    Huang, S.
    Zheng, W.
    Lian, J.
    Yang, X.
    MEDICAL PHYSICS, 2022, 49 (06) : E735 - E735
  • [27] A new validation method of thoracic CT to CT deformable image registration
    Dawoud, S. M.
    Smith, D. W.
    Roberts, N.
    Sebag-Montefiore, D. J.
    Crellin, A. M.
    Crosby, T.
    Radhakrishna, G.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S247 - S247
  • [28] Sensitivity of 4D-CT Pulmonary Ventilation Imaging to Deformable Image Registration Algorithms and Metrics
    Yamamoto, T.
    Kabus, S.
    Klinder, T.
    Lorenz, C.
    von Berg, J.
    Keall, P.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [29] Deformable Vessel-Based Registration Using Landmark-Guided Coherent Point Drift
    Hu, Yipeng
    Rijkhorst, Erik-Jan
    Manber, Richard
    Hawkes, David
    Barratt, Dean
    MEDICAL IMAGING AND AUGMENTED REALITY, 2010, 6326 : 60 - 69
  • [30] Validation of deformable image registration algorithms on CT images of ex vivo porcine bladders with fiducial markers
    Wognum, S.
    Heethuis, S. E.
    Rosario, T.
    Hoogeman, M. S.
    Bel, A.
    MEDICAL PHYSICS, 2014, 41 (07)