Double intrastromal corneal ring segment implantation: a new approach for improved clinical outcomes in keratoconus patients

被引:0
|
作者
Coscarelli, Sandro [1 ]
Sieiro, Reinaldo de Oliveira [2 ,3 ]
Fernandes, Victoria Moreira [2 ,3 ]
Coscarelli, Sandro P. [1 ]
Torquetti, Leonardo [4 ]
机构
[1] Ennio Coscarelli Eye Clin, BR-30140001 Belo Horizonte, MG, Brazil
[2] Med Sci Minas Gerais Eye Inst, BR-30260080 Belo Horizonte, Brazil
[3] Fac Med Sci Minas Gerais, BR-30260080 Belo Horizonte, Brazil
[4] Ctr Excellence Ophthalmol, BR-35660017 Para De Minas, Brazil
关键词
keratoconus; cornea; intrastromal corneal ring segments; refractive surgery; FOLLOW-UP; MODERATE; ARC;
D O I
10.18240/ijo.2024.11.07
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To evaluate the clinical outcomes after subsequent implantation of a new intrastromal corneal ring segment (ICRS) model followed by an additional short-arc ICRS implant in keratoconus patients.<br /> METHODS: This retrospective single-arm cohort study evaluated 25 eyes of 21 keratoconus patients implanted with the new ICRS followed by 140-arch length ICRS (140ICRS) implantation. Uncorrected distance visual acuity (UDVA, logMAR), corrected distance visual acuity (CDVA, logMAR), sphere, astigmatism, keratometry, spherical equivalent (SE), and asphericity were compared preoperatively and postoperatively after both ICRS implantation. RESULTS: The average follow-up time after 140-ICRS implantation was 6.40 +/- 2.20mo. The mean preoperative UDVA improved from 1.27 +/- 0.14 preoperative to 0.52 +/- 0.26 after both ICRS implantation (P=0.03). The mean sphere value reduced from-5.34 +/- 2.74 preoperatively to-2.06 +/- 1.84 postoperatively (P<0.001) after the first ICRS implantation and decreased to-0.59 +/- 1.54 postoperatively (P<0.00 1) after 140-ICRS implantation. The mean preoperative astigmatism was-3.72 +/- 1.56 and improved to-2.82 +/- 1.08 after the first ICRS implantation, and following the 140-ICRS implantation, the mean astigmatism was-1.37 +/- 0.67 (P=0.001). The SE and asphericity changes were statistically significant (P<0.001). The researchers did not find intraoperative or postoperative complications for both procedures.<br /> CONCLUSION: The combination of 2 different ICRSs can efficiently regularize the cornea, reduce the SE, and improve visual acuity in selected keratoconus patients.
引用
收藏
页码:2023 / 2030
页数:8
相关论文
共 50 条
  • [21] Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
    Basiony, Ahmed I.
    Abdulfattah, Mohammad M. E. Mohammad
    Ibrahim, Asmaa M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (01) : 28 - 38
  • [22] Long term outcome of Intrastromal corneal ring segment in keratoconus
    Kang, M. J.
    Lee, J. H.
    Choi, M. H.
    Joo, C. K.
    ACTA OPHTHALMOLOGICA, 2017, 95
  • [23] Visual and Refractive Outcomes and Tomographic Changes after Femtosecond Laser-assisted Intrastromal Corneal Ring Segment Implantation in Patients with Keratoconus
    Hashemian, Seyed Javad
    Farshchian, Nooshin
    Foroutam-Jazi, Alireza
    Jafari, Mohammad Ebrahim
    Hashemian, Mahsa Sadat
    Hashemian, Seyed Mahyar
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2018, 13 (04) : 376 - 382
  • [24] Efficacy of single or paired intrastromal corneal ring segment implantation combined with collagen crosslinking in keratoconus
    Yeung, Sonia N.
    Ku, Judy Y. F.
    Lichtinger, Alejandro
    Low, Stephanie A. W.
    Kim, Peter
    Rootman, David S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (08): : 1146 - 1151
  • [25] Comparison of deep anterior lamellar keratoplasty and intrastromal corneal ring segment implantation in advanced keratoconus
    Ozerturk, Yusuf
    Sari, Esin Sogutlu
    Kubaloglu, Anil
    Koytak, Arif
    Pinero, David
    Akyol, Sibel
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02): : 324 - 332
  • [26] Intrastromal corneal ring segment implantation in paracentral keratoconus with perpendicular topographic astigmatism and comatic axis
    Fernandez-Vega-Cueto, Luis
    Lisa, Carlos
    Alfonso-Bartolozzi, Belen
    Madrid-Costa, David
    Alfonso, Jose F.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (04) : 1540 - 1545
  • [27] Soft contact lens fitting after intrastromal corneal ring segment implantation to treat keratoconus
    Carballo-Alvarez, J.
    Puell, M. C.
    Cuina, R.
    Diaz-Valle, D.
    Vazquez, J. M.
    Benitez-del-Castillo, J. M.
    CONTACT LENS & ANTERIOR EYE, 2014, 37 (05): : 377 - 381
  • [28] Femtosecond laser implantation of a 340-degree intrastromal corneal ring segment in keratoconus: Short-term outcomes
    Sadoughi, Mohammad Mehdi
    Einollahi, Bahram
    Veisi, Amir Reza
    Zare, Mohammad
    Sedaghat, Mohammad Reza
    Roshandel, Danial
    Einollahi, Neda
    Rezaei, Javad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (10): : 1251 - 1256
  • [29] Corneal hydrops after intrastromal corneal ring segment implantation
    Kaya, Vedat
    Kaynak, Pelin
    Basarir, Berna
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (05): : 816 - 816
  • [30] Refractive and Visual Outcomes After Intacs vs Ferrara Intrastromal Corneal Ring Segment Implantation for Keratoconus: A Comparative Study
    Kaya, Vedat
    Utine, Canan Asli
    Karakus, Sezen Harmanci
    Kavadarli, Isilay
    Yilmaz, Omer Faruk
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (12) : 907 - 912