A microcantilever-based viscometer for inline determination of liquid viscosity

被引:0
|
作者
Esmaeili, Sahar [1 ]
Shahrouzi, Javad Rahbar [1 ]
机构
[1] Sahand Univ Technol, Fac Chem Engn, Sahand New Town, Tabriz, Iran
来源
ENGINEERING RESEARCH EXPRESS | 2025年 / 7卷 / 01期
关键词
microcantilever; microfluidic; viscometer; viscosity; viscosity measurement; MICROFLUIDIC VISCOMETER; TECHNOLOGIES; RHEOMETER; RHEOLOGY; SYSTEM;
D O I
10.1088/2631-8695/adabba
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Inline viscosity monitoring is crucial for process control in many industrial plants. In this study, a viscometer was designed and fabricated based on microfluidic technology, and the influence of effective parameters on its performance was investigated. The construction of the viscometer involved the fabrication of two microcantilevers using polydimethylsiloxane. One microcantilever was designed with a circular cross-section featuring a diameter of 300 mu m, while the other was crafted with a triangular cross-section, characterized by a base of 270 mu m and a height of 250 mu m. Both microcantilevers measured 3 mm in height and were meticulously positioned within separate millichannels; each dimensioned at 2 x 5 x 30 mm3. The precision required for the millichannels and additional components was achieved using a mini-CNC milling machine. To evaluate the performance of the viscometer, a series of water-glycerol solutions comprising 50%, 60%, 65%, 70%, 75%, and 80% glycerol were injected into a microchannel. The flow rate was systematically varied between 3 and 18 ml min-1 in increments of 3 ml min-1, utilizing a syringe pump for precise control. The resultant displacement of the microcantilever, attributed to the fluid flow, was meticulously recorded using a digital camera. According to the experimental results, the displacement curves of circular and triangular microcantilevers are linear with viscosity; increasing the viscosity and flow rate of the fluid passing through the millichannel increases the microcantilever displacement rate. The response time of the microcantilever with a circular cross-section is 3 to 9 s, and that of the microcantilever with a triangular cross-section is 2 to 12 s. Also, the results of multiple tests in the same conditions showed that the system has a repeatability error of 4%. Finally, it can be concluded that the proposed device can be used to measure the viscosity of liquids within a specific range.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Optimization modeling of analyte adhesion over an inclined microcantilever-based biosensor
    Khaled, ARA
    Vafai, K
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (08) : 1220 - 1229
  • [42] Development of a microcantilever-based biosensor for detecting Programmed Death Ligand 1
    Neairat, Tajweed
    Al-Gawati, Mahmoud
    Ain, Qura Tul
    Assaifan, Abdulaziz K.
    Alshamsan, Aws
    Alarifi, Abdulaziz
    Alodhayb, Abdullah N.
    Alzahrani, Khalid E.
    Albrithen, Hamad
    SAUDI PHARMACEUTICAL JOURNAL, 2024, 32 (06)
  • [43] Size-dependent behaviour of electrically actuated microcantilever-based MEMS
    Hamed Farokhi
    Mergen H. Ghayesh
    International Journal of Mechanics and Materials in Design, 2016, 12 : 301 - 315
  • [44] PDMS Microcantilever-Based Flow Sensor Integration for Lab-on-a-Chip
    Nezhad, Amir Sanati
    Ghanbari, Mahmood
    Agudelo, Carlos G.
    Packirisamy, Muthukumaran
    Bhat, Rama B.
    Geitmann, Anja
    IEEE SENSORS JOURNAL, 2013, 13 (02) : 601 - 609
  • [45] 3,4-Methylenedioxymethylamphetamine detection using a microcantilever-based biosensor
    Tseng, You-Chen
    Chang, Jeng-Shian
    Lin, Shiming
    Chao, Sheng D.
    Liu, Chih-Hao
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 182 : 163 - 167
  • [46] Induced Mass Change Technique for Glucose Detection in Microcantilever-based Sensors
    Nor, Mardhiah Mohd
    Bais, Badariah
    Abd Aziz, Norazreen
    Ab Rahim, Rosminazuin
    Majlis, Burhanuddin Yeop
    2012 10TH IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE), 2012, : 340 - 343
  • [47] Microcantilever-based weather station for temperature, humidity and flow rate measurement
    Ma, Rong-Hua
    Lee, Chia-Yen
    Wang, Yu-Hsiang
    Chen, Hao-Jen
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2008, 14 (07): : 971 - 977
  • [48] Geometry optimization of uncoated silicon microcantilever-based gas density sensors
    Boudjiet, M. T.
    Bertrand, J.
    Mathieu, F.
    Nicu, L.
    Mazenq, L.
    Leichle, T.
    Heinrich, M.
    Pellet, C.
    Dufour, I.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 600 - 607
  • [49] A microcantilever-based gas flow sensor for flow rate and direction detection
    Ma, Rong-Hua
    Chou, Po-Cheng
    Wang, Yu-Hsiang
    Hsueh, Tzu-Han
    Fu, Lung-Ming
    Lee, Chia-Yen
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2009, 15 (08): : 1201 - 1205
  • [50] Microcantilever-Based In Situ Temperature-Programmed Desorption (TPD) Technique
    Xu, Pengcheng
    Li, Xinyu
    Zhou, Yufan
    Chen, Ying
    Wang, Xuefeng
    Jia, Hao
    Li, Ming
    Yu, Haitao
    Li, Xinxin
    JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2023, 14 (02): : 567 - 575