Optimal Design of Vibration Control of Adjacent Building Structures Based on Inerter

被引:0
|
作者
Tang, Jianjun [1 ]
Kang, Xiaofang [1 ]
机构
[1] Anhui Jianzhu Univ, Sch Civil Engn, Hefei 230601, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Adjacent buildings; Inerter; Monte Carlo pattern search method; Optimal design; Vibration control; TUNED MASS DAMPERS; SEISMIC RESPONSE; HYBRID CONTROL; HYSTERETIC DAMPERS; SYSTEM; BRIDGE;
D O I
10.1007/s40999-025-01097-x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the inerter is applied to adjacent building structures, and discusses the influence of different layout methods of the inerter on the vibration control performance. Multi-degree-of-freedom structures are taken as the object of study, and inerters are used as the connectors between the building structures. The layout of inerters are parallel connection and Z-type connection between adjacent structures, respectively. Firstly, the coupled dynamic equations of the adjacent multi-degree-of-freedom structure and the inerter are established. The peak displacement response of the controlled primary structure is taken as the objective function for optimization. The frequency ratio and damping ratio of the system are numerically optimized by the Monte Carlo pattern search method with the objective of improving the performance of the vibration control system. Secondly, the system's robustness and stability are analyzed. Finally, time-domain simulation analysis is conducted under the action of several real and artificial waves. The results of the study show that the parallel connection can reduce the root mean square value of the displacement response of the structure by up to 76.615%, while the Z-type connection can reach 79.471%. A 30% increase in the optimized damping ratio results in the peak of the objective function increasing by 22.32% for the parallel connection, whereas it increases by only 9.79% for the Z-type connection. Robustness and stability of the system can be improved by adopting the Z-type connection compared with the parallel connection.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Seismic Assessment and Optimal Design for Structures with Clutching Inerter Dampers
    Li, Luyu
    Liang, Qigang
    JOURNAL OF ENGINEERING MECHANICS, 2020, 146 (04)
  • [32] The optimal design of negative stiffness inerter passive dampers for structures
    Chowdhury, Sudip
    Banerjee, Arnab
    Adhikari, Sondipon
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2023, 258
  • [33] Closed-form solutions for the optimal design of inerter-based dynamic vibration absorbers
    Barredo, Eduardo
    Blanco, Andres
    Colin, Jorge
    Penagos, Victor M.
    Abundez, Arturo
    Gerardo Vela, Luis
    Meza, Virgilio
    Cruz, Roller H.
    Mayen, Jan
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2018, 144 : 41 - 53
  • [34] Study on Optimal Design of Grotto-Eave System with Cable Inerter Viscous Damper for Vibration Control
    Huang, Jizhong
    Zhang, Ruoyu
    Luo, Qingyang
    Guo, Xiuwei
    Cao, Meigen
    BUILDINGS, 2022, 12 (05)
  • [35] Optimal design and performance evaluation of a novel hysteretic friction tuned inerter damper for vibration control systems
    Hua, Xu-gang
    Tai, Yu-ji
    Huang, Zhi-wen
    Chen, Zheng-qing
    STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (08):
  • [36] Exact H2 optimal solutions to inerter-based isolation systems for building structures
    Sun, Hongxin
    Zuo, Lei
    Wang, Xiuyong
    Peng, Jian
    Wang, Wenxi
    STRUCTURAL CONTROL & HEALTH MONITORING, 2019, 26 (06):
  • [37] Optimal tuning of SMA inerter for simultaneous wind induced vibration control of high-rise building and energy harvesting
    Das, Sourav
    Chakraborty, Arunasis
    Barua, Ipshita
    SMART MATERIALS AND STRUCTURES, 2021, 30 (02)
  • [38] A Graph-Based Methodology for Optimal Design of Inerter-Based Passive Vibration Absorbers With Minimum Complexity
    He, Haonan
    Li, Yuan
    Wang, Zixiao
    Jiang, Jason Zheng
    Burrow, Steve
    Neild, Simon
    Conn, Andrew
    STRUCTURAL CONTROL & HEALTH MONITORING, 2024, 2024
  • [39] Parameters Optimization and Performance Evaluation of the Tuned Inerter Damper for the Seismic Protection of Adjacent Building Structures
    Kang, Xiaofang
    Wu, Jian
    Wang, Xinqi
    Lei, Shancheng
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2024, 138 (01): : 551 - 593
  • [40] On the Vibration Suppression and Energy Harvesting of Building Structures Using an Electromagnetic-Inerter-Absorber
    Joubaneh, Eshagh F.
    Barry, Oumar R.
    Zuo, Lei
    PROCEEDINGS OF THE ASME 11TH ANNUAL DYNAMIC SYSTEMS AND CONTROL CONFERENCE, 2018, VOL 2, 2018,