Highly Corrosion-Resistant Ultrafine Silver Fiber Biopotential Sensor for Long-Term Monitoring

被引:0
|
作者
Wang, Lanmin [1 ,2 ,3 ]
Luo, Dan [1 ,2 ,3 ]
Yang, Ying [1 ,2 ,3 ]
Wu, Han [1 ,2 ,3 ]
Peterson, Joel [4 ]
Gustafsson, Stefan [5 ]
Guo, Li [4 ]
Niu, Xin [3 ,6 ]
Liu, Hao [1 ,2 ,3 ]
机构
[1] Tiangong Univ, Sch Text Sci & Engn, Tianjin 300387, Peoples R China
[2] Tiangong Univ, Minist Educ, Key Lab Adv Text Composite Mat, Tianjin 300387, Peoples R China
[3] Tiangong Univ, Inst Intelligent Wearable Elect Text, Tianjin 300387, Peoples R China
[4] Univ Boras, Dept Text Technol, S-50332 Boras, Sweden
[5] Univ Boras, Text Labs, S-50332 Boras, Sweden
[6] Tiangong Univ, Sch Arts, Minist Educ, Key Lab Adv Text Composite Mat, Tianjin 300387, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
biopotential dry electrodes; fabric biopotentialsensor; metallic yarns; preservatives; preservationmechanisms; ELECTRONIC TEXTILES;
D O I
10.1021/acsami.4c22905
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Fabric electrodes are an important part of long-term medical-health-monitoring garments, but sweat corrosion can greatly affect their longevity and stability. In this study, the metal fabric biopotential sensor was chemically modified with 3-mercaptopropyltrimethoxysilane (MPTS). Ag/AgCl was formed on the electrode surface by constant voltage deposition. Ag/AgCl/3-Mercaptopropyltrimethoxysilane/silver-plated nylon electrodes (Ag/AgCl/MPTS/SPNE), Ag/AgCl/3-mercaptopropyltrimethoxysilane/silver-plated copper wire electrodes (Ag/AgCl/MPTS/SPCWE), and Ag/AgCl/3-mercaptopropyltrimethoxysilane/sterling silver yarn electrodes (Ag/AgCl/MPTS/SSYE) were prepared. Molecular dynamics (MD) simulations using Forcite were performed to investigate the anticorrosion mechanism of MPTS. The effects of the MPTS dip-coating time and chlorination parameters on the electrochemical properties were investigated. The corrosion resistance of the biopotential sensor was tested in simulated sweat and NaCl solutions. We analyzed the suitability of the biopotential sensor by the softness test, abrasion resistance test, washing resistance test, and motion noise resistance test. Ag/AgCl/MPTS/SSYE provides optimal corrosion resistance, comfort, motion noise resistance, and electrical properties. It can be used for wearable applications such as long-term electrocardiogram (ECG) signals, electromyogram (EMG) signals, and neuromuscular electrical stimulation (NMES).
引用
收藏
页码:20790 / 20805
页数:16
相关论文
共 50 条
  • [41] The microstructural instability of a hot corrosion resistant superalloy during long-term exposure
    Hou, J. S.
    Guo, J. T.
    Yang, G. X.
    Zhou, L. Z.
    Qin, X. Z.
    Ye, H. Q.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2008, 498 (1-2): : 349 - 358
  • [42] Nanoremediation and long-term monitoring of brownfield soil highly polluted with As and Hg
    Gil-Diaz, M.
    Rodriguez-Valdes, E.
    Alonso, J.
    Baragano, D.
    Gallego, J. R.
    Lobo, M. C.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 675 : 165 - 175
  • [43] Low-Power Sensor Module for Long-Term Activity Monitoring
    Leuenberger, Kaspar
    Gassert, Roger
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2237 - 2241
  • [44] A Self-Powered Magnetostrictive Sensor for Long-Term Earthquake Monitoring
    Ren, Limin
    Yu, Kun
    Tan, Yisong
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (03)
  • [45] Oxygen sensor for real-time and in situ long-term monitoring
    Lazik, D
    Geistlinger, H
    GROUNDWATER 2000, 2000, : 429 - 430
  • [46] Long-term monitoring FBG-based cable load sensor
    Zhang, Zhichun
    Zhou, Zhi
    Wang, Chuan
    Ou, Jinping
    SMART STRUCTURES AND MATERIALS 2006: SMART SENSOR MONITORING SYSTEMS AND APPLICATIONS, 2006, 6167
  • [47] Long-Term Temperature Monitoring in CMS Using Fiber Optic Sensors
    Saccomanno, Andrea
    Laudati, Armando
    Szillasi, Zoltan
    Beni, Noemi
    Cutolo, Antonello
    Irace, Andrea
    Giordano, Michele
    Buontempo, Salvatore
    Cusano, Andrea
    Breglio, Giovanni
    IEEE SENSORS JOURNAL, 2012, 12 (12) : 3392 - 3398
  • [48] A Hybrid Energy Scavenging Sensor for Long-term Mechanical Strain Monitoring
    Huang, Chenling
    Chakrabartty, Shantanu
    2011 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2011, : 2473 - 2476
  • [49] Compensated Surface Plasmon Resonance Sensor for Long-Term Monitoring Applications
    Fallauto, Carmelo
    Liu, Yu
    Perrone, Guido
    Vallan, Alberto
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (05) : 1287 - 1292
  • [50] A Wireless Sensor Node For Long-Term Monitoring In Life Science Applications
    Passow, Peter
    Stoll, Norbert
    Junginger, Steffen
    Thurow, Kerstin
    2013 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2013, : 898 - 901