Highly Corrosion-Resistant Ultrafine Silver Fiber Biopotential Sensor for Long-Term Monitoring

被引:0
|
作者
Wang, Lanmin [1 ,2 ,3 ]
Luo, Dan [1 ,2 ,3 ]
Yang, Ying [1 ,2 ,3 ]
Wu, Han [1 ,2 ,3 ]
Peterson, Joel [4 ]
Gustafsson, Stefan [5 ]
Guo, Li [4 ]
Niu, Xin [3 ,6 ]
Liu, Hao [1 ,2 ,3 ]
机构
[1] Tiangong Univ, Sch Text Sci & Engn, Tianjin 300387, Peoples R China
[2] Tiangong Univ, Minist Educ, Key Lab Adv Text Composite Mat, Tianjin 300387, Peoples R China
[3] Tiangong Univ, Inst Intelligent Wearable Elect Text, Tianjin 300387, Peoples R China
[4] Univ Boras, Dept Text Technol, S-50332 Boras, Sweden
[5] Univ Boras, Text Labs, S-50332 Boras, Sweden
[6] Tiangong Univ, Sch Arts, Minist Educ, Key Lab Adv Text Composite Mat, Tianjin 300387, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
biopotential dry electrodes; fabric biopotentialsensor; metallic yarns; preservatives; preservationmechanisms; ELECTRONIC TEXTILES;
D O I
10.1021/acsami.4c22905
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Fabric electrodes are an important part of long-term medical-health-monitoring garments, but sweat corrosion can greatly affect their longevity and stability. In this study, the metal fabric biopotential sensor was chemically modified with 3-mercaptopropyltrimethoxysilane (MPTS). Ag/AgCl was formed on the electrode surface by constant voltage deposition. Ag/AgCl/3-Mercaptopropyltrimethoxysilane/silver-plated nylon electrodes (Ag/AgCl/MPTS/SPNE), Ag/AgCl/3-mercaptopropyltrimethoxysilane/silver-plated copper wire electrodes (Ag/AgCl/MPTS/SPCWE), and Ag/AgCl/3-mercaptopropyltrimethoxysilane/sterling silver yarn electrodes (Ag/AgCl/MPTS/SSYE) were prepared. Molecular dynamics (MD) simulations using Forcite were performed to investigate the anticorrosion mechanism of MPTS. The effects of the MPTS dip-coating time and chlorination parameters on the electrochemical properties were investigated. The corrosion resistance of the biopotential sensor was tested in simulated sweat and NaCl solutions. We analyzed the suitability of the biopotential sensor by the softness test, abrasion resistance test, washing resistance test, and motion noise resistance test. Ag/AgCl/MPTS/SSYE provides optimal corrosion resistance, comfort, motion noise resistance, and electrical properties. It can be used for wearable applications such as long-term electrocardiogram (ECG) signals, electromyogram (EMG) signals, and neuromuscular electrical stimulation (NMES).
引用
收藏
页码:20790 / 20805
页数:16
相关论文
共 50 条
  • [31] Feasibility assessment of an optical sensor for long-term electrocardiogram monitoring
    Zhao, Jing
    Li, Mingwei
    Wang, Qi
    Zhang, Hongxia
    Liu, Tiegen
    Jia, Dagong
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS XI, 2021, 11901
  • [32] Wireless sensor networks for long-term structural health monitoring
    Meyer, Jonas
    Bischoff, Reinhard
    Feltrin, Glauco
    Motavalli, Masoud
    SMART STRUCTURES AND SYSTEMS, 2010, 6 (03) : 263 - 275
  • [33] Long-term relative performance of embedded sensor and surface mounted electrode for corrosion monitoring of steel in concrete structures
    Karthick, S. P.
    Muralidharan, S.
    Saraswathy, V.
    Thangavel, K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 192 : 303 - 309
  • [34] Flexible silver nanowire dry electrodes for long-term electrocardiographic monitoring
    Kun Huang
    Junchen Liu
    Sen Lin
    Yufeng Wu
    Enfu Chen
    Zhaofeng He
    Ming Lei
    Advanced Composites and Hybrid Materials, 2022, 5 : 220 - 228
  • [35] Flexible silver nanowire dry electrodes for long-term electrocardiographic monitoring
    Huang, Kun
    Liu, Junchen
    Lin, Sen
    Wu, Yufeng
    Chen, Enfu
    He, Zhaofeng
    Lei, Ming
    ADVANCED COMPOSITES AND HYBRID MATERIALS, 2022, 5 (01) : 220 - 228
  • [36] Embroidered Electrode with Silver/Titanium Coating for Long-Term ECG Monitoring
    Weder, Markus
    Hegemann, Dirk
    Amberg, Martin
    Hess, Markus
    Boesel, Luciano F.
    Abaecherli, Roger
    Meyer, Veronika R.
    Rossi, Rene M.
    SENSORS, 2015, 15 (01) : 1750 - 1759
  • [37] A Long-Term Monitoring Method of Corrosion Damage of Prestressed Anchor Cable
    Li, Jianzhi
    Wang, Chen
    Zhao, Yiyao
    MICROMACHINES, 2023, 14 (04)
  • [38] Porous Microneedle Array Electrode Using Interstitial Fluid as Conductive Fillers for Biosafe and Long-Term Biopotential Monitoring
    Xue, Zifan
    Zhang, Yunfan
    Zheng, Yuting
    Shen, Shengnan
    Li, Hui
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2025, 72 (03) : 1323 - 1330
  • [39] Long-term monitoring of cardiorespiratory patterns in drug-resistant epilepsy
    Goldenholz, Daniel M.
    Kuhn, Amanda
    Austermuehle, Alison
    Bachler, Martin
    Mayer, Christopher
    Wassertheurer, Siegfried
    Inati, Sara K.
    Theodore, William H.
    EPILEPSIA, 2017, 58 (01) : 77 - 84
  • [40] A sulphide resistant Ag|AgCl reference electrode for long-term monitoring
    Macedo, David S.
    Vepsalainen, Mikko
    Rodopoulos, Theo
    Peacock, Stephen
    Hogan, Conor F.
    ANALYST, 2024, 149 (21) : 5225 - 5231