Continuous glucose monitoring (Dexcom g6) in people with diabetes after kidney transplantation

被引:0
|
作者
Jakubowska, Zuzanna [1 ]
Malyszko, Jolanta [1 ]
机构
[1] Med Univ Warsaw, Dept Nephrol Dialysis & Internal Dis, Banacha 1A, PL-02097 Warsaw, Poland
关键词
Kidney transplantation; continuous glucose measurement; pressure-induced sensor attenuations; time in range; quality of life; GLYCEMIC CONTROL; VARIABILITY;
D O I
10.1080/0886022X.2024.2413007
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesUse of continuous glucose monitoring-CGM in patients on kidney replacement therapy including kidney transplant recipients, may improve glycemic control and detection of hypoglycemia. However, studies in this population in particular in kidney transplant recipients are very limited.MethodsThe study aimed to evaluate glycemic profiles using the Dexcom G6 CGM system for 30 d a personal smartphone in people with diabetes after kidney transplantation and to assess the impact of monthly use of the CGM system on glycemic control and quality of life in this group.ResultsOver 8 months, 9 people after kidney transplantation were included in the study (7 women, median age 57 years), 8 people with new-onset diabetes after transplantation (NODAT), and 1 person with diabetes mellitus type 1. The time since kidney transplantation in each of the study participants was less than 2 years. In 7 people with NODAT, the time in range was above 70%. In all study participants, hyperglycemia was observed mainly in the afternoon (2-6 pm). In some patients, pressure-induced sensor attenuations (PISAs) were noted. There was no effect of the use of Dexcom G6 on the HbA1c value. There was no impact of the use of the Dexcom G6 system on the perception of overall quality of life, but monthly use had a positive impact on the perception of the quality of health.ConclusionsCGM systems seem to be a promising method for assessing glycemic control in people with diabetes after kidney transplantation. More extensive research is needed to assess safety and usefulness in everyday practice.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Accuracy of the Dexcom G6 Glucose Sensor during Aerobic, Resistance, and Interval Exercise in Adults with Type 1 Diabetes
    Guillot, Florian H.
    Jacobs, Peter G.
    Wilson, Leah M.
    Youssef, Joseph El
    Gabo, Virginia B.
    Branigan, Deborah L.
    Tyler, Nichole S.
    Ramsey, Katrina
    Riddell, Michael C.
    Castle, Jessica R.
    BIOSENSORS-BASEL, 2020, 10 (10):
  • [32] Accuracy of the Dexcom G7 Continuous Glucose Monitoring Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA-2 Study)
    Avari, Parizad
    Pushparatnam, Reshaba
    Leelarathna, Lala
    Tan, Tricia
    Frankel, Andrew H.
    Oliver, Nick
    Reddy, Monika
    DIABETES TECHNOLOGY & THERAPEUTICS, 2025,
  • [33] Long-term cost-effectiveness of Dexcom G6 real-time continuous glucose monitoring system in people with type 1 diabetes in Australia: Response to letter from Hellmund, Richard and Welsh, Zoe
    Isitt, John J.
    Roze, Stephane
    DIABETIC MEDICINE, 2023, 40 (02)
  • [34] Dexcom G4 Platinum (Pediatric) Continuous Glucose Monitoring System
    Coates, Shawn
    Melek, Mina
    Honeywell, Marlon
    Campbell, Ellen
    Gaffney, Anneka J.
    Allen, Eboni
    Robinson, Temple
    US PHARMACIST, 2015, 40 (05) : 61 - 62
  • [35] Cost-Effectiveness of the MiniMed 780G System vs. Multiple Daily Injections (MDI) Used with the Dexcom G6 Continuous Glucose Monitoring (CGM) System
    Kommareddi, Mallika
    Vigersky, Robert A.
    DIABETES, 2024, 73
  • [36] G6 continuous glucose monitoring system feature use and its associations with glycaemia in Europe
    Acciaroli, Giada
    Parkin, Christopher G.
    Thomas, Roy
    Layne, Jennifer
    Norman, Gregory J.
    Leone, Keri
    DIABETIC MEDICINE, 2023, 40 (06)
  • [37] 'Long-term cost-effectiveness of Dexcom G6 real-time continuous glucose monitoring system in people with type 1 diabetes in Australia: Comments on J. J. Isitt et al.'
    Hellmund, Richard
    Welsh, Zoe
    DIABETIC MEDICINE, 2023, 40 (02)
  • [38] Audit of glycaemic control in patients with type 1 diabetes who use the dexcom G6 sensor
    Almutairi, M.
    Mcgrath, J.
    Begley, J.
    Idriss, S.
    Woods, C. P.
    Moore, K. B.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2022, 191 (SUPPL 4) : 102 - 102
  • [39] Evaluating the early impact of dexcom G6 CGM in patients with type 1 diabetes attending a rural diabetes service
    McEvoy, R. P.
    O'Donovan, M.
    Hannon, M. J.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2022, 191 (SUPPL 4) : 120 - 120
  • [40] RANDOMIZED TRIAL OF REMOTE NOCTURNAL CONTINUOUS GLUCOSE MONITORING AT DIABETES CAMPS USING THE DEXCOM G4 PLATINUM AND DIAS
    Buckingham, B.
    Keith-Hynes, P.
    Peyser, T.
    DeSalvo, D.
    Caswell, K.
    Ferrari, G.
    Wilson, D.
    Anjo, B.
    Harris, B.
    Clinton, P.
    Place, J.
    Mize, L. B.
    Kovatchev, B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A56 - A56