Continuous glucose monitoring (Dexcom g6) in people with diabetes after kidney transplantation

被引:0
|
作者
Jakubowska, Zuzanna [1 ]
Malyszko, Jolanta [1 ]
机构
[1] Med Univ Warsaw, Dept Nephrol Dialysis & Internal Dis, Banacha 1A, PL-02097 Warsaw, Poland
关键词
Kidney transplantation; continuous glucose measurement; pressure-induced sensor attenuations; time in range; quality of life; GLYCEMIC CONTROL; VARIABILITY;
D O I
10.1080/0886022X.2024.2413007
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesUse of continuous glucose monitoring-CGM in patients on kidney replacement therapy including kidney transplant recipients, may improve glycemic control and detection of hypoglycemia. However, studies in this population in particular in kidney transplant recipients are very limited.MethodsThe study aimed to evaluate glycemic profiles using the Dexcom G6 CGM system for 30 d a personal smartphone in people with diabetes after kidney transplantation and to assess the impact of monthly use of the CGM system on glycemic control and quality of life in this group.ResultsOver 8 months, 9 people after kidney transplantation were included in the study (7 women, median age 57 years), 8 people with new-onset diabetes after transplantation (NODAT), and 1 person with diabetes mellitus type 1. The time since kidney transplantation in each of the study participants was less than 2 years. In 7 people with NODAT, the time in range was above 70%. In all study participants, hyperglycemia was observed mainly in the afternoon (2-6 pm). In some patients, pressure-induced sensor attenuations (PISAs) were noted. There was no effect of the use of Dexcom G6 on the HbA1c value. There was no impact of the use of the Dexcom G6 system on the perception of overall quality of life, but monthly use had a positive impact on the perception of the quality of health.ConclusionsCGM systems seem to be a promising method for assessing glycemic control in people with diabetes after kidney transplantation. More extensive research is needed to assess safety and usefulness in everyday practice.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] The Dexcom G6 Continuous Glucose Monitoring System
    Renaud, Amy
    Mahdavian, Soheyla
    Smith, Ukamaka Dike
    Larose-Pierre, Margareth
    Carter, Chenita
    Honeywell, Marlon
    US PHARMACIST, 2021, 46 (10) : 18 - 20
  • [2] Performance of the Dexcom G6 Continuous Glucose Monitoring System in Pregnant Women with Diabetes
    Castorino, Kristin
    Polsky, Sarit
    O'Malley, Grenye
    Levister, Camilla
    Nelson, Kristen
    Farfan, Christian
    Brackett, Scott
    Puhr, Sarah
    Levy, Carol J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (12) : 943 - 947
  • [3] Performance Evaluation of Dexcom G6 Continuous Glucose Monitoring and Capillary Blood Glucose after Hospital Discharge in Patients with Diabetes
    Galindo, Rodolfo J.
    Davis, Georgia
    Idrees, Thaer
    Urrutia, Maria A.
    Zamudio, Karla W.
    Albury, Bonnie S.
    Migdal, Alexandra
    Vellanki, Priyathama
    Fayfman, Maya
    Perez-Guzman, Mireya C.
    Cardona, Saumeth
    Pasquel, Francisco J.
    Peng, Limin
    Umpierrez, Guillermo E.
    DIABETES, 2021, 70
  • [4] Accuracy of Dexcom G6 Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients With Diabetes
    Davis, Georgia M.
    Spanakis, Elias K.
    Migdal, Alexandra L.
    Singh, Lakshmi G.
    Albury, Bonnie
    Urrutia, Maria Agustina
    Zamudio-Coronado, K. Walkiria
    Scott, William H.
    Doerfler, Rebecca
    Lizama, Sergio
    Satyarengga, Medha
    Munir, Kashif
    Galindo, Rodolfo J.
    Vellanki, Priyathama
    Cardona, Saumeth
    Pasquel, Francisco J.
    Peng, Limin
    Umpierrez, Guillermo E.
    DIABETES CARE, 2021, 44 (07) : 1641 - 1646
  • [5] Dynamic Interference Testing Results with the Dexcom G6 Continuous Glucose Monitoring Device
    Pfutzner, Andreas
    Jensch, Hendrick
    Srikanthamoorthy, Geethan
    Kuhl, Christian
    Setford, Steven J.
    Grady, Mike
    Holt, Elizabeth H.
    Thome, Nicole
    DIABETES, 2023, 72
  • [6] Comparison of Dexcom G6 Continuous Glucose Monitoring and Point -of-Care Blood Glucose Testing in Hospitalized Patients with Diabetes
    Davis, Georgia M.
    Migdal, Alexandra
    Urrutia, Maria A.
    Zamudio-Coronado, K. Walkiria
    Perez-Guzman, Mireya C.
    Albury, Bonnie S.
    Cardona, Saumeth
    Galindo, Rodolfo J.
    Idrees, Thaer
    Vellanki, Priyathama
    Pasquel, Francisco J.
    Peng, Limin
    Umpierrez, Guillermo E.
    DIABETES, 2021, 70
  • [7] Continuous Glucose Monitoring Using the Dexcom G6 in Cardiac Surgery During the Postoperative Period
    Insler, Steven R.
    Wakefield, Brett
    Debs, Andrea
    Brake, Kelly
    Nwosu, Ikenna
    Isaacs, Diana
    Bena, James
    Lansang, M. Cecilia
    ENDOCRINE PRACTICE, 2024, 30 (07) : 610 - 615
  • [8] ACCURACY OF THE DEXCOM G6 CONTINUOUS GLUCOSE MONITOR IN HOSPITALIZED PEDIATRIC PATIENTS WITH TYPE 1 DIABETES
    Cobry, E.
    Pyle, L.
    Towers, L.
    Jost, E.
    Karami, A.
    Berget, C.
    Forlenza, G.
    Waterman, L.
    Wadwa, P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A205 - A206
  • [9] Comparison of Dexcom G6 Continuous Glucose Monitoring Performance between Abdomen and Upper Arm Placement in Hospitalized Patients with Diabetes
    Migdal, Alexandra
    Zamudio, Karla W.
    Perez-Guzman, Mireya C.
    Idrees, Thaer
    Albury, Bonnie S.
    Davis, Georgia
    Urrutia, Maria A.
    Galindo, Rodolfo J.
    Vellanki, Priyathama
    Fayfman, Maya
    Cardona, Saumeth
    Castro-Revoredo, Iris A.
    Pasquel, Francisco J.
    Peng, Limin
    Umpierrez, Guillermo E.
    DIABETES, 2021, 70
  • [10] RELIABILITY OF THE DEXCOM G6 CONTINUOUS GLUCOSE MONITOR DURING HYPERBARIC OXYGEN EXPOSURE
    Huang, E.
    Demirel, S.
    Bliss, C.
    Savaser, D.
    Castle, J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A130 - A131