Reproducibility of 3D thoracic aortic displacement from 3D cine balanced SSFP at 3T without contrast enhancement

被引:0
|
作者
Merton, Renske [1 ,2 ]
Bosshardt, Daan [1 ,2 ]
Strijkers, Gustav J. [2 ,3 ,4 ]
Nederveen, Aart J. [1 ,2 ,4 ]
Schrauben, Eric M. [1 ,2 ]
van Ooij, Pim [1 ,2 ,4 ]
机构
[1] Univ Amsterdam, Radiol & Nucl Med, Amsterdam UMC Locat, Amsterdam, Netherlands
[2] Amsterdam Cardiovasc Sci, Amsterdam, Netherlands
[3] Univ Amsterdam, Biomed Phys & Engn, Amsterdam UMC Locat, Amsterdam, Netherlands
[4] Amsterdam Movement Sci, Amsterdam, Netherlands
关键词
3; T; 3D cine bSSFP; aorta; aortic motion; displacement; nonrigid registration; ROOT MOTION; MRI; REGISTRATION; RELIABILITY; VELOCITY; STRESS; ECG;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Aortic motion has direct impact on the mechanical stresses acting on the aorta. In aortic disease, increased stiffness of the aorta may lead to decreased aortic motion over time, which could be a predictor for aortic dissection or rupture. This study investigates the reproducibility of obtaining 3D displacement and diameter maps quantified using accelerated 3D cine MRI at 3 T. Methods: A noncontrast-enhanced, free-breathing 3D cine sequence based on balanced SSFP and pseudo-spiral undersampling with high spatial isotropic resolution was developed (spatial/temporal resolution [1.6mm](3)/67 ms). The thoracic aorta of 14 healthy volunteers was prospectively scanned three times at 3 T: twice on the same day and a third time 2weeks later. Aortic displacement was calculated using iterative closest point nonrigid registration of manual segmentations of the 3D aorta at end-systole and mid-diastole. Interexamination and interobserver regional analysis of mean displacement for five regions of interest was performed using Bland-Altman analysis. Additionally, a complementary voxel-by-voxel analysis was done, allowing a more local inspection of the method. Results: No significant differences were found in mean and maximum displacement for any of the regions of interest for the interexamination and interobserver analysis. The maximum displacement measured in the lower half of the ascending aorta was 11.0 +/- 3.4mm(range: 3.0-17.5mm) for the first scan. The smallest detectable change in mean displacement in the lower half of the ascending aorta was 3 mm. Conclusion: Detailed 3D cine balanced SSFP at 3 T allows for reproducible quantification of systolic-diastolic mean aortic displacement within acceptable limits.
引用
收藏
页码:466 / 480
页数:15
相关论文
共 50 条
  • [31] Contactless 3D Fingerprint Identification Without 3D Reconstruction
    Zheng, Qian
    Kumar, Ajay
    Pan, Gang
    2018 6TH INTERNATIONAL WORKSHOP ON BIOMETRICS AND FORENSICS (IWBF), 2018,
  • [32] Quantification of Perfusion and Permeability in Multiple Sclerosis Dynamic Contrast-Enhanced MRI in 3D at 3T
    Ingrisch, Michael
    Sourbron, Steven
    Morhard, Dominik
    Ertl-Wagner, Birgit
    Kuempfel, Tania
    Hohlfeld, Reinhard
    Reiser, Maximilian
    Glaser, Christian
    INVESTIGATIVE RADIOLOGY, 2012, 47 (04) : 252 - 258
  • [33] High resolution 3D diffusion MRI of carotid plaque on 3T
    Yibin Xie
    Wei Yu
    Zhaoyang Fan
    Christopher T Nguyen
    Jing An
    Zhaoqi Zhang
    Debiao Li
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [34] 3D gradient enhancement
    Fukai Zhao
    Xinguo Liu
    The Visual Computer, 2014, 30 : 113 - 126
  • [35] 3D gradient enhancement
    Zhao, Fukai
    Liu, Xinguo
    VISUAL COMPUTER, 2014, 30 (01): : 113 - 126
  • [36] 3D Cine Displacement-Encoded MRI of Pulsatile Brain Motion
    Soellinger, Michaela
    Rutz, Andrea K.
    Kozerke, Sebastian
    Boesiger, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) : 153 - 162
  • [37] A 3D Model of Human Cerebrovasculature Derived from 3T Magnetic Resonance Angiography
    Wieslaw L. Nowinski
    Ihar Volkau
    Yevgen Marchenko
    A. Thirunavuukarasuu
    Ting Ting Ng
    Val M. Runge
    Neuroinformatics, 2009, 7 : 23 - 36
  • [38] A 3D Model of Human Cerebrovasculature Derived from 3T Magnetic Resonance Angiography
    Nowinski, Wieslaw L.
    Volkau, Ihar
    Marchenko, Yevgen
    Thirunavuukarasuu, A.
    Ng, Ting Ting
    Runge, Val M.
    NEUROINFORMATICS, 2009, 7 (01) : 23 - 36
  • [39] MetaPose: Fast 3D Pose from Multiple Views without 3D Supervision
    Usman, Ben
    Tagliasacchi, Andrea
    Saenko, Kate
    Sud, Avneesh
    2022 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2022), 2022, : 6749 - 6760
  • [40] 3D without the glasses
    Neil A. Dodgson
    Nature, 2013, 495 : 316 - 317