Reproducibility of 3D thoracic aortic displacement from 3D cine balanced SSFP at 3T without contrast enhancement

被引:0
|
作者
Merton, Renske [1 ,2 ]
Bosshardt, Daan [1 ,2 ]
Strijkers, Gustav J. [2 ,3 ,4 ]
Nederveen, Aart J. [1 ,2 ,4 ]
Schrauben, Eric M. [1 ,2 ]
van Ooij, Pim [1 ,2 ,4 ]
机构
[1] Univ Amsterdam, Radiol & Nucl Med, Amsterdam UMC Locat, Amsterdam, Netherlands
[2] Amsterdam Cardiovasc Sci, Amsterdam, Netherlands
[3] Univ Amsterdam, Biomed Phys & Engn, Amsterdam UMC Locat, Amsterdam, Netherlands
[4] Amsterdam Movement Sci, Amsterdam, Netherlands
关键词
3; T; 3D cine bSSFP; aorta; aortic motion; displacement; nonrigid registration; ROOT MOTION; MRI; REGISTRATION; RELIABILITY; VELOCITY; STRESS; ECG;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Aortic motion has direct impact on the mechanical stresses acting on the aorta. In aortic disease, increased stiffness of the aorta may lead to decreased aortic motion over time, which could be a predictor for aortic dissection or rupture. This study investigates the reproducibility of obtaining 3D displacement and diameter maps quantified using accelerated 3D cine MRI at 3 T. Methods: A noncontrast-enhanced, free-breathing 3D cine sequence based on balanced SSFP and pseudo-spiral undersampling with high spatial isotropic resolution was developed (spatial/temporal resolution [1.6mm](3)/67 ms). The thoracic aorta of 14 healthy volunteers was prospectively scanned three times at 3 T: twice on the same day and a third time 2weeks later. Aortic displacement was calculated using iterative closest point nonrigid registration of manual segmentations of the 3D aorta at end-systole and mid-diastole. Interexamination and interobserver regional analysis of mean displacement for five regions of interest was performed using Bland-Altman analysis. Additionally, a complementary voxel-by-voxel analysis was done, allowing a more local inspection of the method. Results: No significant differences were found in mean and maximum displacement for any of the regions of interest for the interexamination and interobserver analysis. The maximum displacement measured in the lower half of the ascending aorta was 11.0 +/- 3.4mm(range: 3.0-17.5mm) for the first scan. The smallest detectable change in mean displacement in the lower half of the ascending aorta was 3 mm. Conclusion: Detailed 3D cine balanced SSFP at 3 T allows for reproducible quantification of systolic-diastolic mean aortic displacement within acceptable limits.
引用
收藏
页码:466 / 480
页数:15
相关论文
共 50 条
  • [21] Improved assessment of aortic 3D blood flow with combined k-t accelerated 3D CINE bSSFP & 4D flow MRI
    Kelly B Jarvis
    Can Wu
    Shivraman Giri
    Susanne Schnell
    Alex J Barker
    Jeremy D Collins
    James C Carr
    Michael Markl
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [22] Symmetry enhancement and closing of knots in 3d/3d correspondence
    Dongmin Gang
    Kazuya Yonekura
    Journal of High Energy Physics, 2018
  • [23] Symmetry enhancement and closing of knots in 3d/3d correspondence
    Gang, Dongmin
    Yonekura, Kazuya
    JOURNAL OF HIGH ENERGY PHYSICS, 2018, (07):
  • [24] 3D balanced SSFP UTE MRI for multiple contrasts whole brain imaging
    Shen, Xin
    Caverzasi, Eduardo
    Yang, Yang
    Liu, Xiaoxi
    Green, Ari
    Henry, Roland G.
    Emir, Uzay
    Larson, Peder E. Z.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (02) : 702 - 714
  • [25] Correction for displacement artifacts in 3D phase contrast imaging
    Thunberg, P
    Wigström, L
    Ebbers, T
    Karlsson, M
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (05) : 591 - 597
  • [26] MR imaging of the internal auditory canal and inner ear at 3T: Comparison between 3D driven equilibrium and 3D balanced fast field echo sequences
    Byun, Jun Soo
    Kim, Hyung-Jin
    Yim, You Jeong
    Kim, Sung Tae
    Jeon, Pyoung
    Kim, Keon Ha
    Kim, Sam Soo
    Jeon, Yong Hwan
    Lee, Jiwon
    KOREAN JOURNAL OF RADIOLOGY, 2008, 9 (03) : 212 - 218
  • [27] 3D Spatial Recognition without Spatially Labeled 3D
    Ren, Zhongzheng
    Misra, Ishan
    Schwing, Alexander G.
    Girdhar, Rohit
    2021 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, CVPR 2021, 2021, : 13199 - 13208
  • [28] Single Image 3D Without a Single 3D Image
    Fouhey, David F.
    Hussain, Wajahat
    Gupta, Abhinav
    Hebert, Martial
    2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2015, : 1053 - 1061
  • [29] 3D frameworks from 3D printers
    Ian D. Williams
    Nature Chemistry, 2014, 6 : 953 - 954
  • [30] From 3D view to 3D print
    Dima, M.
    Farisato, G.
    Bergomi, M.
    Viotto, V.
    Magrin, D.
    Greggio, D.
    Farinato, J.
    Marafatto, L.
    Ragazzoni, R.
    Piazza, D.
    SPACE TELESCOPES AND INSTRUMENTATION 2014: OPTICAL, INFRARED, AND MILLIMETER WAVE, 2014, 9143