Validity of Wrist-Worn Activity Tracker Heart Rate Detection in Fontan Patients during Exercise

被引:0
|
作者
Pierick, Alyson R. [1 ]
Burke, Kelly J. [1 ]
Prusi, Megan [1 ]
Largent, Bethany [1 ]
Yu, Sunkyung [1 ]
Lowery, Ray E. [1 ]
Duimstra, Ashley [1 ]
Hansen, Jesse E. [1 ]
机构
[1] Univ Michigan, Div Pediat Cardiol, 1540 East Hosp Dr, Ann Arbor, MI 48109 USA
关键词
PHYSICAL ACTIVITY; SINGLE VENTRICLE; AMBULATORY TRACKING; EXERCISE PHYSIOLOGY; QUALITY-OF-LIFE; PHYSICAL-ACTIVITY; CIRCULATION; ACCURACY; MONITORS; CHILDREN; IMPROVE; ADULTS;
D O I
10.1249/MSS.0000000000003567
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose Physical activity and a healthy lifestyle play an essential role in optimizing long-term health in patients with Fontan physiology. Wrist-worn activity trackers may be useful in medically directed exercise programs for patients with Fontan physiology. The objective of this study was to measure the validity of Garmin and Fitbit activity tracker heart rate detection in patients with Fontan circulation when compared with electrocardiogram during cardiopulmonary exercise testing (CPET). Methods Forty-seven Fontan patients undergoing CPET for clinical indications were included and wore activity trackers during CPET. Heart rate via the activity tracker was collected at baseline, maximal exercise, and recovery. Patient heart rates, peak VO2, and peak respiratory exchange ratio were collected using standard CPET protocols and equipment. Heart rate at each time point was compared between the activity trackers and CPET electrocardiogram. Results Median age of participants was 17.1 yr, 15.1 yr since Fontan completion. Mean percentage of predicted peak VO2 was 56.8%, with a z-score of -3.2, and 61.7% of participants completing a maximal CPET. Baseline mean oxygen saturation was 92.9% and 90.0% at maximal exercise. Activity trackers demonstrated mean absolute percentage error <10% at most time points, comparable with other studies. Demographics, Fontan-associated comorbidities, and echocardiogram findings did not impact the accuracy. Conclusions Consumer-oriented wrist-worn activity trackers show promising accuracy for heart rate monitoring in medically directed exercise programs for adolescents and young adults with Fontan physiology. Further validation across different exercise modalities is needed.
引用
收藏
页码:280 / 284
页数:5
相关论文
共 50 条
  • [41] Effect of skin tone and activity on the performance of wrist-worn optical beat-to-beat heart rate monitoring
    Puranen, Antti
    Halkola, Tuomas
    Kirkeby, Ole
    Vehkaoja, Antti
    2020 IEEE SENSORS, 2020,
  • [42] Accuracy Of Predicted Energy Expenditure From A Wrist-worn Activity Monitor During Short And Long Duration Exercise
    Van Camp, Cailyn A.
    St Bernard, Kaitlyn
    Culler, Kaitlyn
    Moore, Rebecca W.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2021, 53 (08): : 17 - 17
  • [43] Estimation of Heart Rate Recovery after Stair Climbing Using a Wrist-Worn Device
    Sokas, Daivaras
    Petrenas, Andrius
    Daukantas, Saulius
    Rapalis, Andrius
    Paliakaite, Birute
    Marozas, Vaidotas
    SENSORS, 2019, 19 (09)
  • [44] Learning based Quality Indicator Aiding Heart Rate Estimation in Wrist-Worn PPG
    Lutin, E.
    Biswas, D.
    Simoes-Capela, N.
    Van Hoof, C.
    Van Helleputte, N.
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 7063 - 7067
  • [45] Robust Heart Rate Monitoring by a Single Wrist-Worn Accelerometer Based on Signal Decomposition
    Zhao, Chao
    Zeng, Wenru
    Hu, Dandan
    Liu, Hong
    IEEE SENSORS JOURNAL, 2021, 21 (14) : 15962 - 15971
  • [46] Heartefacts: Augmenting Mobile Video Sharing Using Wrist-Worn Heart Rate Sensors
    Vermeulen, Jo
    MacDonald, Lindsay
    Schoning, Johannes
    Beale, Russell
    Carpendale, Sheelagh
    DIS 2016: PROCEEDINGS OF THE 2016 ACM CONFERENCE ON DESIGNING INTERACTIVE SYSTEMS, 2016, : 712 - 723
  • [47] The validity of the commercially-available, low-cost, wrist-worn Movband accelerometer during treadmill exercise and free-living physical activity
    Barkley, Jacob E.
    Glickman, Ellen
    Fennell, Curtis
    Kobak, Mallory
    Frank, Megan
    Farnell, Gregory
    JOURNAL OF SPORTS SCIENCES, 2019, 37 (07) : 735 - 740
  • [48] Convulsive seizure detection using a wrist-worn electrodermal activity and accelerometry biosensor
    Poh, Ming-Zher
    Loddenkemper, Tobias
    Reinsberger, Claus
    Swenson, Nicholas C.
    Goyal, Shubhi
    Sabtala, Mangwe C.
    Madsen, Joseph R.
    Picard, Rosalind W.
    EPILEPSIA, 2012, 53 (05) : e93 - e97
  • [49] Detection and analysis of pulse waves during sleep via wrist-worn actigraphy
    Zschocke, Johannes
    Kluge, Maria
    Pelikan, Luise
    Graf, Antonia
    Glos, Martin
    Mueller, Alexander
    Mikolajczyk, Rafael
    Bartsch, Ronny P.
    Penzel, Thomas
    Kantelhardt, Jan W.
    PLOS ONE, 2019, 14 (12):
  • [50] Validity of Wrist-Worn Activity Trackers for Estimating VO2max and Energy Expenditure
    Passler, Stefanie
    Bohrer, Julian
    Bloechinger, Lukas
    Senner, Veit
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (17)