Transcatheter aortic valve replacement in a bicuspid aortic valve with membranous interventricular septum aneurysm communicating with aortic root: a case report

被引:0
|
作者
Xi, Ziwei [1 ]
Yao, Jing [1 ]
Song, Guangyuan [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Intervent Ctr Valvular Heart Dis, 2 Anzhen Rd, Beijing 100029, Peoples R China
关键词
Transcatheter aortic valve replacement; Membranous interventricular septum aneurysm; Case report;
D O I
10.1093/ehjcr/ytae523
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Membranous interventricular septum aneurysm (MISA) is a rare abnormality occurring in 0.3% of patients with congenital heart disease, which thereby increases anatomical complexity.Case summary Transcatheter aortic valve replacement (TAVR) procedure was planned for a 71-year-old female patient from East Asia with a type 1 bicuspid aortic valve diagnosed with severe aortic stenosis by transthoracic echocardiography (TTE). Pre-procedural multidetector computed tomography (MDCT) clearly revealed an extremely horizontal aorta and a MISA originating from the sub-annulus with the upper edge extending 7.2 mm above the annulus. A probable communicating flow between the left ventricle and the aorta was confirmed by reviewing the TTE images. Moreover, there was a calcified raphe between the left- and right-coronary cusps. A downsized balloon-expandable valve (a 23 mm Sapien 3 valve with an additional 2 mL dilation) was therefore chosen and deployed with a 100/0 aortic/ventricular ratio position. The TTE post-implantation indicated a trace perivalvular leakage. The cardiac MDCT performed post-procedure, at the 6-month, and 12-month follow-ups demonstrated complete sealing and significant healing of the aneurysm.Discussion Transcatheter aortic valve replacement utilizing a balloon-expandable valve was successfully performed for a case with membranous interventricular septum aneurysm extending above the annulus. Comprehensive imaging analysis before the procedure is crucial for TAVR with challenging anatomical conditions.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Successful Transcatheter Aortic Valve Replacement in an Elderly Patient with Calcified Bicuspid Aortic Valve with Calcified Raphe: A Case Report
    Taduru, Siva Sagar
    Ramakrishnan, Madhuri
    Pamulapati, Hema
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [42] Successful Aortic Valve Replacement With Perceval Bioprosthesis for Aortic Stenosis With Membranous Ventricular Septum Aneurysm
    Nishijima, Shuhei
    Nakamura, Yoshitsugu
    Gersak, Borut
    Namiki, Shigetaka
    Kouzaki, Tsunashi
    Tsuchiya, Yoshiki
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2021, 16 (02) : 195 - 197
  • [43] A RARE CASE OF INTERVENTRICULAR SEPTAL ANEURYSM ASSOCIATED WITH BICUSPID AORTIC VALVE
    Banerjee, Sanchari
    Paulraj, Shweta
    Sanchez, Andres M. Cordova
    Azhar, Atika
    Sandhu, Michael
    Roseman, Hal M.
    CHEST, 2022, 162 (04) : 243A - 244A
  • [44] Transaxillary Transcatheter Aortic Valve Replacement in a Patient With Previous Aortic Valve-Sparing Root Replacement: A Case Report
    EL-Andari, Ryaan
    Bozso, Sabin J.
    Kang, Jimmy J. H.
    Baghaffar, Abdullah
    Berube, Joel
    Moon, Michael C.
    Tyrrell, Benjamin D.
    Mathew, Anoop
    Welsh, Robert C.
    Nagendran, Jeevan
    CJC OPEN, 2023, 5 (03) : 233 - 236
  • [45] Interventricular septum aneurysm: Two differently managed cases and association with bicuspid aortic valve
    Deaconu, Alexandru
    Lancovici, Silvia
    Wellnhofer, Ernst
    Berger, Alexander
    Gebker, Rolf
    Pieske, Burkert
    Pasic, Miralem
    Kelle, Sebastian
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 201 : 438 - 440
  • [46] Aortic Root Replacement to Accommodate Future Valve-in-Valve Transcatheter Aortic Valve Replacement
    Harloff, Morgan T.
    Papoy, Andrew R.
    Hirji, Sameer A.
    Percy, Edward D.
    Yazdchi, Farhang
    Aghayev, Ayaz
    Kaneko, Tsuyoshi
    ANNALS OF THORACIC SURGERY, 2021, 111 (06): : E437 - E438
  • [47] Delayed Aortic Dissection After Transcatheter Aortic Valve Replacement for Stenotic Bicuspid Valve
    Roberts, Charles S.
    Hassan, Murad H.
    Mccullough, Kyle A.
    Eisenga, John B.
    AMERICAN JOURNAL OF CARDIOLOGY, 2025, 238 : 85 - 88
  • [48] Bicuspid Aortic Valve What to Image in Patients Considered for Transcatheter Aortic Valve Replacement?
    Kong, William K. F.
    Delgado, Victoria
    Bax, Jeroen J.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2017, 10 (09)
  • [49] Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis Using Lotus Valve System
    Chan, Albert W.
    Wong, Daniel
    Charania, Jahangir
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (01) : 157 - 163
  • [50] Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Stenosis
    Mentias, Amgad
    Sarrazin, Mary Vaughan
    Desai, Milind Y.
    Saad, Marwan
    Horwitz, Phillip A.
    Kapadia, Samir
    Girotra, Saket
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (19) : 2518 - 2519