Transcatheter aortic valve replacement in a bicuspid aortic valve with membranous interventricular septum aneurysm communicating with aortic root: a case report

被引:0
|
作者
Xi, Ziwei [1 ]
Yao, Jing [1 ]
Song, Guangyuan [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Intervent Ctr Valvular Heart Dis, 2 Anzhen Rd, Beijing 100029, Peoples R China
关键词
Transcatheter aortic valve replacement; Membranous interventricular septum aneurysm; Case report;
D O I
10.1093/ehjcr/ytae523
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Membranous interventricular septum aneurysm (MISA) is a rare abnormality occurring in 0.3% of patients with congenital heart disease, which thereby increases anatomical complexity.Case summary Transcatheter aortic valve replacement (TAVR) procedure was planned for a 71-year-old female patient from East Asia with a type 1 bicuspid aortic valve diagnosed with severe aortic stenosis by transthoracic echocardiography (TTE). Pre-procedural multidetector computed tomography (MDCT) clearly revealed an extremely horizontal aorta and a MISA originating from the sub-annulus with the upper edge extending 7.2 mm above the annulus. A probable communicating flow between the left ventricle and the aorta was confirmed by reviewing the TTE images. Moreover, there was a calcified raphe between the left- and right-coronary cusps. A downsized balloon-expandable valve (a 23 mm Sapien 3 valve with an additional 2 mL dilation) was therefore chosen and deployed with a 100/0 aortic/ventricular ratio position. The TTE post-implantation indicated a trace perivalvular leakage. The cardiac MDCT performed post-procedure, at the 6-month, and 12-month follow-ups demonstrated complete sealing and significant healing of the aneurysm.Discussion Transcatheter aortic valve replacement utilizing a balloon-expandable valve was successfully performed for a case with membranous interventricular septum aneurysm extending above the annulus. Comprehensive imaging analysis before the procedure is crucial for TAVR with challenging anatomical conditions.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Aortic Root Imaging in the Era of Transcatheter Aortic Valve Implantation/Transcatheter Aortic Valve Replacement
    Escobedo, Carlos
    Schoenhagen, Paul
    REVISTA ESPANOLA DE CARDIOLOGIA, 2013, 66 (11): : 839 - 841
  • [32] Valve-in-Valve Transcatheter Aortic Valve Replacement With Intracardiac Echocardiography Focusing on the Membranous Septum
    Taniguchi, Tomohiko
    Hasegawa, Yuhei
    Kim, Kitae
    Ehara, Natsuhiko
    Furukawa, Yutaka
    CIRCULATION JOURNAL, 2023, 87 (07) : 1038 - 1038
  • [33] Recent Advances in Aortic Valve Disease: Highlights From a Bicuspid Aortic Valve to Transcatheter Aortic Valve Replacement
    Augoustides, John G. T.
    Wolfe, Yanika
    Walsh, Elizabeth K.
    Szeto, Wilson Y.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2009, 23 (04) : 569 - 576
  • [34] Late Contained Aortic Root Rupture After Transcatheter Aortic Valve Replacement for Bicuspid Aortic Stenosis
    Ochiai, Tomoki
    Yoon, Sung-Han
    Flint, Nir
    Sharma, Rahul
    Patel, Chinar
    Patel, Vivek
    Chakravarty, Tarun
    Nakamura, Mamoo
    Cheng, Wen
    Makkar, Raj
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (14) : E121 - E122
  • [35] Transcatheter Valve Replacement for Bicuspid Aortic Stenosis
    Otto, Catherine M.
    Newby, David E.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 326 (11): : 1009 - 1010
  • [36] Local Experience: Transcatheter Aortic Valve Replacement on Bicuspid Aortic Valve with Lotus Valve System
    Luk, Ngai Hong Vincent
    De Backer, Ole
    Sondergaard, Lars
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (16) : S16 - S17
  • [37] Transcatheter Aortic Valve Implantation in a Patient With Severe Bicuspid Aortic Valve Stenosis and Ascending Aortic Aneurysm
    Chen, Mao
    Feng, Yuan
    Mazzitelli, Domenico
    Tang, Hong
    Wei, Xin
    Zhao, Zhen-Gang
    Xu, Yuan-Ning
    Liao, Yan-Biao
    Huang, De-Jia
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (07) : E83 - E84
  • [38] An aortic root abscess in a patient with a bicuspid aortic valve: a case report
    Balzan, Elyse
    Borg, Alexander
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2020, 4 (05)
  • [39] ANEURYSM OF INTERVENTRICULAR SEPTUM WITH AORTIC VALVE MALFORMATION IN AN INFANT
    MORTON, P
    MURTAGH, JG
    OHARA, MD
    BRITISH HEART JOURNAL, 1969, 31 (06): : 807 - &
  • [40] Transcatheter aortic valve replacement failure: a case report of the bicuspid aortic valve type 0 with a single coronary artery
    Suzuki, Ryo
    Suzuki, Masato
    Takayanagi, Ryo
    Ohori, Shunsuke
    Ito, Toshiro
    JOURNAL OF SURGICAL CASE REPORTS, 2022, 2022 (03):