Correlation between ultrasound-measured inferior vena cava diameter and peripherally inserted central catheter measured central venous pressure in low birth weight infants

被引:0
|
作者
Li, Guang-Hong [1 ]
Du, Xiao-Qun [1 ]
Sun, Dong-Sheng [1 ]
Huang, Hui-Yi [1 ]
机构
[1] Huadu Dist Peoples Hosp Guangzhou, Dept Pdediat, Guangzhou 510800, Guangdong, Peoples R China
来源
关键词
Vena cava; central venous pressure; ultrasound; central venous catheter; low birth weight infants; umbilical vein; CRITICALLY-ILL CHILDREN; VOLUME;
D O I
10.62347/BMDJ4584
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: To evaluate the correlation between ultrasound-measured inferior vena cava (IVC) diameter and central venous pressure (CVP) measured by peripherally inserted central catheter (PICC) in low birth weight infants (LBWI) and explore potential influencing factors. Methods: This retrospective study included 120 LBWI with birth weights below 2500 gwho required umbilical vein catheterization at Huadu District People's Hospital of Guangzhou from May 2022 to April 2024. Infants were categorized based on PICC catheterization into two groups. Clinical data, including ultrasound-measured IVC small diameter (SD) and large diameter (LD) at the level of the left portal vein, were collected. The SD/LD ratio (S/L) was calculated, and logistic regression analyses (univariate and multivariate) were performed to identifyfactors influencing PICC catheterization. Correlations between SD, LD, S/L, and CVP were analyzed. Results: Multivariate logistic regression identified gestational age, birth weight, SD, S/L, and CVP as significantfactors influencing PICC catheterization in LBWI (all P < 0.05). SD and S/Lshowed a positive correlation with CVP (both P < 0.05). The S/L ratio was significantly correlated with gestational age, birth weight, ventilator mode, tricuspid regurgitation, and vasoactive drug use (all P < 0.05). Conclusion: Birth weight, SD, S/L ratio, and CVP are significant factors affecting PICC placement in LBWI. There is a notable correlation between ultrasound-measured IVC SD and S/L ratio and PICC-measured CVP in LBWIs.
引用
收藏
页码:2266 / 2275
页数:10
相关论文
共 50 条
  • [31] Comparison of the central venous pressure from internal jugular vein and the pressure measured from the peripherally inserted antecubital central catheter (PICCP) in liver transplantation recipients
    Yun, Jung-Yeon
    Park, So-Hee
    Cho, Dae-Soon
    Jeung, Hae-Jeung
    Lee, Soon-Ae
    Seo, So Jin
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2011, 61 (04) : 281 - 287
  • [32] The diameter of the inferior vena cava provides a noninvasive way of calculating central venous pressure in neonates
    Sato, Yoshiaki
    Kawataki, Motoyoshi
    Hirakawa, Akihiro
    Toyoshima, Katsuaki
    Kato, Taichi
    Itani, Yasufumi
    Hayakawa, Masahiro
    ACTA PAEDIATRICA, 2013, 102 (06) : e241 - e246
  • [33] Complications of percutaneously inserted central venous lines in low birth weight infants
    Duncan, S.
    Stewart, D.
    Corneal, J.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2008, 56 (01) : 447 - 448
  • [34] Evaluating the Effect of High Dose Versus Low Dose Heparin in Peripherally Inserted Central Catheter in Very Low Birth Weight Infants
    Barekatain, Behzad
    Armanian, Amir Mohammad
    Salamaty, Ladan
    Shahsanai, Armindokht
    Safaei, Ali
    IRANIAN JOURNAL OF PEDIATRICS, 2018, 28 (03)
  • [35] Inferior Vena Cava Diameter (IVCD) Measured with Transesophageal Echocardiography (TEE) Can Be Used to Derive the Central Venous Pressure (CVP) in Anesthetized Mechanically Ventilated Patients
    Arthur, Mary E.
    Landolfo, Carolyn
    Wade, Marlene
    Castresana, Manuel R.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (02): : 140 - 149
  • [36] Association between Peripherally Inserted Central Venous Catheter Insertion Site and Complication Rates in Preterm Infants
    Bashir, Rani A.
    Swarnam, Kamala
    Vayalthrikkovil, Sakeer
    Yee, Wendy
    Soraisham, Amuchou S.
    AMERICAN JOURNAL OF PERINATOLOGY, 2016, 33 (10) : 945 - 950
  • [37] A randomized trial comparing peripherally inserted central venous catheters and peripheral intravenous catheters in infants with very low birth weight
    Janes, M
    Kalyn, A
    Pinelli, J
    Paes, B
    JOURNAL OF PEDIATRIC SURGERY, 2000, 35 (07) : 1040 - 1044
  • [38] Central venous pressure values in very low birth weight infants
    Inglis, G. D. T.
    Davies, M. W.
    Dunster, K. R.
    ACTA PAEDIATRICA, 2007, 96 : 119 - 119
  • [39] COMPLICATIONS ASSOCIATED WITH TWO DIFFERENT TYPES OF PERCUTANEOUSLY INSERTED CENTRAL VENOUS CATHETER IN VERY LOW BIRTH WEIGHT INFANTS
    Chu, S. M.
    Tsai, M. H.
    Lien, R.
    Huang, R. H.
    Hsu, F. J.
    Huang, C. Y.
    ACTA PAEDIATRICA, 2010, 99 : 93 - 93
  • [40] DOES THE ILIAC/INFERIOR VENA CAVA CENTRAL VENOUS PRESSURE (IVCP) CORRESPOND WELL WITH IAP MEASURED VIA THE BLADDER?: A MULTICENTRE ANALYSIS
    De Keulenaer, B. L.
    De Waete, J. J.
    Dabrowski, W.
    Cea, Izura J. J.
    Picaza, Rios G. J.
    Bodnar, Z.
    Kaloiani, V
    Litvin, A.
    Jenkins, I. R.
    ACTA CLINICA BELGICA, 2009, 64 (03): : 269 - 269