Correlation between ultrasound-measured inferior vena cava diameter and peripherally inserted central catheter measured central venous pressure in low birth weight infants

被引:0
|
作者
Li, Guang-Hong [1 ]
Du, Xiao-Qun [1 ]
Sun, Dong-Sheng [1 ]
Huang, Hui-Yi [1 ]
机构
[1] Huadu Dist Peoples Hosp Guangzhou, Dept Pdediat, Guangzhou 510800, Guangdong, Peoples R China
来源
关键词
Vena cava; central venous pressure; ultrasound; central venous catheter; low birth weight infants; umbilical vein; CRITICALLY-ILL CHILDREN; VOLUME;
D O I
10.62347/BMDJ4584
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: To evaluate the correlation between ultrasound-measured inferior vena cava (IVC) diameter and central venous pressure (CVP) measured by peripherally inserted central catheter (PICC) in low birth weight infants (LBWI) and explore potential influencing factors. Methods: This retrospective study included 120 LBWI with birth weights below 2500 gwho required umbilical vein catheterization at Huadu District People's Hospital of Guangzhou from May 2022 to April 2024. Infants were categorized based on PICC catheterization into two groups. Clinical data, including ultrasound-measured IVC small diameter (SD) and large diameter (LD) at the level of the left portal vein, were collected. The SD/LD ratio (S/L) was calculated, and logistic regression analyses (univariate and multivariate) were performed to identifyfactors influencing PICC catheterization. Correlations between SD, LD, S/L, and CVP were analyzed. Results: Multivariate logistic regression identified gestational age, birth weight, SD, S/L, and CVP as significantfactors influencing PICC catheterization in LBWI (all P < 0.05). SD and S/Lshowed a positive correlation with CVP (both P < 0.05). The S/L ratio was significantly correlated with gestational age, birth weight, ventilator mode, tricuspid regurgitation, and vasoactive drug use (all P < 0.05). Conclusion: Birth weight, SD, S/L ratio, and CVP are significant factors affecting PICC placement in LBWI. There is a notable correlation between ultrasound-measured IVC SD and S/L ratio and PICC-measured CVP in LBWIs.
引用
收藏
页码:2266 / 2275
页数:10
相关论文
共 50 条
  • [21] The efficacy of sonographic measurement of inferior vena cava diameter as an estimate of central venous pressure
    William Ciozda
    Ilan Kedan
    Devin W. Kehl
    Raymond Zimmer
    Raj Khandwalla
    Asher Kimchi
    Cardiovascular Ultrasound, 14
  • [22] THE EFFICACY OF SONOGRAPHIC MEASUREMENT OF INFERIOR VENA CAVA DIAMETER AS AN ESTIMATE OF CENTRAL VENOUS PRESSURE
    Ciozda, W.
    Kedan, I.
    Khandwalla, R.
    Zimmer, R.
    Kimchi, A.
    CARDIOLOGY, 2016, 134 : 156 - 156
  • [23] The efficacy of sonographic measurement of inferior vena cava diameter as an estimate of central venous pressure
    Ciozda, William
    Kedan, Ilan
    Kehl, Devin W.
    Zimmer, Raymond
    Khandwalla, Raj
    Kimchi, Asher
    CARDIOVASCULAR ULTRASOUND, 2016, 14
  • [24] Fluoroscopy-guided transhepatic vena cava cannulation with a peripherally inserted central venous catheter in a pediatric patient with difficult central venous access
    Nath, Sayan
    Naranje, Priyanka
    Kandasamy, Devasenathipathy
    Singh, Akhil Kant
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2023, 39 (02) : 322 - 323
  • [25] PERIPHERALLY INSERTED CENTRAL VENOUS CATHETER AND PERSISTENT LEFT SUPERIOR VENA CAVA: WHAT SHOULD WE KNOW?
    Gatto, M.
    Celli, E.
    Ferrari, I.
    Biava, G.
    Nicastri, E.
    Antinori, A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2023, 25 : D98 - D98
  • [26] Correlation of caval index, inferior vena cava diameter, and central venous pressure in shock patients in the emergency room
    Worapratya, Panita
    Anupat, Sawanya
    Suwannanon, Ruedeekorn
    Wuthisuthimethawee, Prasit
    OPEN ACCESS EMERGENCY MEDICINE, 2014, 6 : 57 - 62
  • [27] Pericardial Effusion in an Extreme Low Birth Weight Neonate with Peripherally Inserted Central Catheter
    Soleimani, Mohammad
    Badiee, Zohreh
    Goudarzi, Razieh Moazami
    IRANIAN JOURNAL OF NEONATOLOGY, 2019, 10 (03) : 99 - 102
  • [28] Extravascular collection of fluid around the vertebra resulting from malpositioning of a peripherally inserted central venous catheter in extremely low birth weight infants
    Mitsufuji, N
    Matsuo, K
    Kakita, S
    Ikuta, H
    JOURNAL OF PERINATAL MEDICINE, 2002, 30 (04) : 341 - 344
  • [29] Sequential inferior vena cava filter insertion and peripherally inserted central catheter placement through upper extremity veins
    Ballard, D. H.
    Jahromi, A. Hamidian
    Weisman, J. A.
    Vea, R.
    D'Agostino, A. M.
    D'Agostino, H. B.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (11) : 1189 - 1193
  • [30] The relationship between superior vena cava diameter and collapsibility and central venous pressure
    Cowie, B. S.
    Kluger, R.
    Rex, S.
    Missant, C.
    ANAESTHESIA AND INTENSIVE CARE, 2015, 43 (03) : 357 - 360