Calibration and test of the Athena On-board Metrology system

被引:0
|
作者
Abreu, Manuel [1 ,2 ]
Cabra, Alexandre [1 ,2 ]
Rebordao, Jose [1 ,2 ]
Goncalves, Nuno M. [1 ,2 ]
Mottini, Sergio [3 ]
Pinto, Joao Costa [4 ]
Santos, Miguel [5 ]
Oddenino, Davide [6 ]
机构
[1] Univ Lisbon, Inst Astrofis & Ciencias Espaco, Lisbon, Portugal
[2] Univ Lisbon, Fac Ciencias, Dept Fis, Lisbon, Portugal
[3] Thales Alenia Space Italia, Rome, Italy
[4] Evoleo Technol, Maia, Portugal
[5] FHP Frezite, Porto, Portugal
[6] ESA ESTEC, Noordwijk, Netherlands
关键词
Athena; On-board metrology system; Optical metrology; fiducial imaging;
D O I
10.1117/12.3019718
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Athena is ESA's X-ray observatory mission designed to address the Hot and Energetic Universe theme. The instrument consists of a single x-ray telescope, supported by a large area mirror based on Silicon Pore Optics technology, focusing the photon flux alternatively onto two different instruments: the Wide Field Imager (WFI) and the X-ray Integral Field Unit (X-IFU). The process of switching the focus between the two instruments is produced by a hexapod structure changing the pointing of the main X-ray mirror. To verify that the mirror optical axis is aligned with each of the instruments, an optical On-board Metrology System (OBM) will be used to estimate the telescope pointing with accuracy better than 0.5 arcsec. The OBM system currently in development at the Institute of Astrophysics and Space Sciences is based on the concept of a projective metrology where a pattern of active fiducials is imaged by an array detector. The position and orientation of the imaged pattern provides the necessary information to reconstruct the fiducial displacements with respect to the calibrated reference points, allowing obtaining an estimate of the pointing absolute knowledge error. The design of the metrology system is presently at Engineering Model level, although it will be tested for performance in normal laboratory conditions. In this work we will present the experimental setup and processing architecture designed for calibration and testing the OBM demonstrator close to operational conditions, namely in what respects to the distance from the OBM Optical Head to the fiducial plane (12 meter). This experimental setup is calibrated to reproduce verifiable fiducial displacements over the OBM telescope field of view at 7.5 micrometre level (1 sigma). This setup allows evaluating the performance of OBM and verify its compliance with requirements of the on-board metrology system for the Athena X-ray Observatory mission.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] The on-board calibration system of the X-ray Imaging Polarimetry Explorer (XIPE)
    Zane, Silvia
    Winter, Berend
    Theobald, Craig
    Theodorou, Theodorus
    Pinchera, Michele
    Muleri, Fabio
    Spada, Francesca
    Sgro, Carmelo
    Zanetti, Davide
    Feng, Hua
    del Monte, Ettore
    Rubini, Alda
    Soffitta, Paolo
    Bellazzini, Ronaldo
    Bozzo, Enrico
    Burwitz, Vadim
    Castro Tirado, Alberto J.
    Costa, Enrico
    Gburek, Szymon
    Goosmann, Rene
    Karas, Vladimir
    Matt, Giorgio
    Nandra, Kirpal
    Pearce, Mark
    Poutanen, Juri
    Reglero, Victor
    Dolores Sabau, Maria
    Santangelo, Andrea
    Tagliaferri, Giampiero
    Tenzer, Christopher
    Vink, Jacco
    Weisskopf, Martin
    SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
  • [22] The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) on-board blackbody calibration system
    Best, FA
    Revercomb, HE
    Knuteson, RO
    Tobin, DC
    Ellington, SD
    Werner, MW
    Adler, DP
    Garcia, RK
    Taylor, JK
    Ciganovich, NN
    Smith, WL
    Bingham, GE
    Elwell, JD
    Scott, DK
    MULTISPECTRAL AND HYPERSPECTRAL REMOTE SENSING INSTRUMENTS AND APPLICATIONS II, 2005, 5655 : 77 - 87
  • [23] Design considerations of the FBAR on-board test
    Xu Xia-xi
    Gao Yang
    Liu Ting-ting
    FIFTH SYMPOSIUM ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATION, 2019, 11023
  • [24] Getting on-board ATE test fixtures
    Lecklider, T
    EE-EVALUATION ENGINEERING, 2004, 43 (03): : 18 - +
  • [25] The Test and Evaluation of GPS On-board Clock
    Xu, Yongliang
    Li, Wei
    Qin, Weijin
    2013 JOINT EUROPEAN FREQUENCY AND TIME FORUM & INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (EFTF/IFC), 2013, : 295 - +
  • [26] TEST STANDARD SPEEDS ON-BOARD PROGRAMMING
    AHRENS, K
    ELECTRONIC DESIGN, 1994, 42 (23) : 107 - &
  • [27] Research on application of visual simulation and test method in subway on-board system
    State Key Laboratory of Rail Traffic Control and Safety, Beijing Jiaotong University, Beijing 100044, China
    Xitong Fangzhen Xuebao, 2008, 4 (896-899):
  • [28] Oldsmobile on-board video system
    Automotive Industries AI, 1998, 178 (12):
  • [29] Intelligent on-board TV system
    Antonov A.A.
    International Journal of Vehicle Safety, 2011, 5 (02) : 156 - 167
  • [30] TRANSIT SYSTEM SWITCHED ON-BOARD
    STEFANID.EJ
    DESIGN NEWS, 1972, 27 (11) : 36 - +